Well Health WH-OX01 Bedienungsanleitung
Well Health
WH-OX01
Lies die bedienungsanleitung für Well Health WH-OX01 (37 Seiten) kostenlos online; sie gehört zur Kategorie . Dieses Handbuch wurde von 47 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 24 Bewertungen. Hast du eine Frage zu Well Health WH-OX01 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/37

English ..................................................................................................... 1
Nederlands .............................................................................................. 6
Français ................................................................................................. 11
Deutsch ................................................................................................. 16
Español .................................................................................................. 21
Italiano .................................................................................................. 26
Polski ..................................................................................................... 31
Product name: Oximeter
Arcle number: WH-OX01
Version: V1.1
Release date: April 2020
FINGER PULSE OXIMETER
USER’S MANUAL

EN - 1
English
OLED display modes
Features
OLED display
Two color OLED display, dierent display modes
Low-power consumpon, connuously four direcon adjustable
Low baery indicator
Automacally power o in 16 seconds when there is no signal
Compact, light in weight, and convenient to carry

EN - 2
English
1.1 InstruconsfortheSafeOperaonand
UseoftheFingerPulseOximeter
• Do not aempt to service the pulse oximeter.
Only qualied service personnel should aempt
any needed internal servicing.
• Do not use the oximeter in situaons where
alarms are required.
• Prolonged use or the paent’s condion may
require changing the sensor site periodically.
• Change sensor site and check skin integrity,
circulatory status and correct alignment at least
every 2 hours.
• Sp02 measurements may be adversely aected
in the presence of high ambient light. Shield the
sensor area (with a surgical towel, for example)
if necessary.
• The following reasons will cause interference:
• High-frequency electrosurgical devices
• Placement of a sensor on an extremity with
a blood pressure cu arterial catheter, or
intravascular line
• The paent has hypotension severe
vasoconstricon severe anemia or hypothermia
• The paent is in cardiac arrest or is in shock
• Fingernail polish or false ngernails may cause
inaccurate Sp02 readings
1.2 Warnings
WARNING
EXPLOSION HAZARD— Do not use the oximeter
in a ammable atmosphere where concentrations of
ammable anesthetics or other materials may occur.
WARNING
Do not throw batteries in re as this may cause them
to explode.
WARNING
Do not attempt to recharge normal dry-cell batteries,
they may leak. And may cause a re or even explode.
WARNING
Do not use the pulse oximeter in an MRI or CT
environment.
CAUTION
Keep the operating environment free of dust,
vibrations, corrosive, or ammable materials, and
extremes of temperature and humidity.
CAUTION
Do not operate the unit if it is damp or wet because
of condensation or spills. Avoid using the equipment
immediately after moving it from a cold environment
to a warm, humid location.
CAUTION Never use sharp or pointed objects to operate the
front-panel key.
CAUTION
The battery must be taken out from the battery
compartment if the device will not be used for a long
time.
CAUTION The device shall only be used if the battery cover
is closed.
CAUTION The battery must be proper disposed according to
local regulation after their use.
1.3 DenionsandSymbols
Whenplugging yourngerIntothe Oximeter, your
nailsurfacemustbeupward.
Instrucons:Please use the medical alcohol to clean
the rubber before each test and clean the tested
nger with alcohol before and aer the test.
• Install two AAA baeries into baery cassee
before covering its cover
• Open the Oximeter by pressing the back part
together, insert one nger with the ngernail
upwards in the Oximeter (ideally up to the end)
and close it by releasing the back part.
• Press buon on the front panel;
• Don’t tremble your nger when the Oximeter is
working. Please don’t move your body.
• Press the buon on the front panel, if you want
change display direcon;
• Read relevant date from display screen.
• The instrument has the sleep mode, no signal will
be received if it is in sleep mode.
• Please replace new baeries when OLED indicates
the baeries are in low power.
Section 1 Safety
Produktspezifikationen
Marke: | Well Health |
Kategorie: | |
Modell: | WH-OX01 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Well Health WH-OX01 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Well Health
4 August 2024
31 Juli 2024
Bedienungsanleitung
- Bell Phones
- Levensweg
- Philips Saeco
- E-4Motion
- Wallner Universal
- ESYNiC
- Neomounts By Newstar
- Gigaset-Elements
- ETNA
- Bike Hanger
- Palm Beach
- Duss
- Thomson Telecom
- Dane Elec
- Go On!
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
5 Oktober 2024
5 Oktober 2024
18 September 2024
Fresh 'n Rebel Clam ANC - 3HP400 Hoofdtelefoon Bedienungsanleitung
14 September 2024