Weller MG 130 Bedienungsanleitung
Weller
Lötmaschine
MG 130
Lies die bedienungsanleitung für Weller MG 130 (5 Seiten) kostenlos online; sie gehört zur Kategorie Lötmaschine. Dieses Handbuch wurde von 41 Personen als hilfreich bewertet und erhielt im Schnitt 4.4 Sterne aus 21 Bewertungen. Hast du eine Frage zu Weller MG 130 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/5

OPERATING MANUAL
Weller Tools GmbH
Carl-Benz-Str. 2
74354 Besigheim, Germany
Tel: +49 (0) 7143 580-0
Fax: +49 (0) 7143 580-108
www.wellerft.com
39077-1 / 0 .20149

72
9. Warranty
Warranty: (except for lters). The time is measured from date of invoice.
Always contact the supplier before returning a product.
The invoice has to be shown at the time of the complaint.
Content
1. Introduction 2
2. Content 2
3. Safety instructions 3
4. Put into operation 3
5. Troubleshooting 4
6. Maintenance and service 5
7. Technical data 6
8. Article numbers 6
9. Warranty 7
1. Introduction
Filter system designed to catch and eliminate hazardous gases and particles in different
applications like soldering, gluing, solvents etc. It is delivered as a complete kit containing
everything required for two work stations.
2. Content
1. Hose connection
2. Top
3. Locks
4. Power intake with fuse and
curcuit breaker
5. Control panel
6. Nozzle x 2
7. Extraction arm x 2
8. Pre lter
9. Main lter
8
9
6
7
1
2
3
4
5
1 year

36
7. Technical data
Width x height x depth 456 x 496 x 200 mm
Weight 12 kg
Sound level at 1 meter > 52 dB(A)
Voltage 100/240 V
Effect 100 watt
Glass tube fuse 2 x 6,3 AT, 250 V
Maximum suction capacity 100 m3/h
Blower capacity 140 m3/h
Micro lter HEPA class H13, Separation degree, MPPS >99,95 %
Gas lter - Separation degree >95 %
Pre lter F7
Filter minitoring system Yes
Warranty (excl. lter) 2 years
ESD approval, SP Dno 230-05-0189
CE-guidelines 73/23, 89/336, 89/392, 91/368,
92/31, 93/44, 93/68
RoHS Yes
8. Article numbers
MG130 Fume extraction 130-1000-ESD
MG130 (2x Arm 0F10 + 2x Nozzle FT-NL) 1 Filter system 30-1055-ESD
MG130 Filter system (2x Arm 0F10 + 2x ALFA-Nozzle) FT91000103
Main lter 30-2000-ESD 1
Pre lter (5 pc 30-2010 F7 s) 1
3. Safety instructions
The unit must not be exposed to temperatures exceeding 50° C, open ames or conden-
sated solvents.
Switch off the lter unit when changing lter.
4. Put into operation
The best possible gas ltration will be achieved if:
- Process air temperature in the gas lter < 38 °C
- Relative humidity < 60 %
- Gas molecules > 30 g / mol (ltration better with larger molecules)
- Boiling temperature of gas molecules > 0 °C
NOTE! The unit may dust some from the main lter after transportation.
Make sure the starting of the lter system is made in an appropriate room.
The suction capacity can be adjusted in three steps by pressing the reset button at the
control panel repeatedly.
Produktspezifikationen
Marke: | Weller |
Kategorie: | Lötmaschine |
Modell: | MG 130 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Weller MG 130 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Lötmaschine Weller
13 Oktober 2024
17 September 2024
2 September 2024
30 August 2024
29 August 2024
29 August 2024
19 August 2024
14 August 2024
13 August 2024
13 August 2024
Bedienungsanleitung Lötmaschine
- Güde
- Powerplus
- UNIMIG
- Holzmann
- Telwin
- Truper
- Ozito
- Cigweld
- Parkside
- Ersa
- Uten
- FERM
- Silverline
- Edsyn
- Basetech
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024