Lies die bedienungsanleitung für Bogen NQ-GA40P3 (4 Seiten) kostenlos online; sie gehört zur Kategorie Empfänger. Dieses Handbuch wurde von 16 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 8.5 Bewertungen. Hast du eine Frage zu Bogen NQ-GA40P3 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

Specications are subject to change.
© Copyright 2022, Bogen Communications LLC
740-00158E 230727
NQ-GA40P3 Integrated Power Amplier
Installation and Use Guide
The NQ-GA40P3 is a 40W plenum-rated Class D integrated power amplier.
Designed to operate over a 10/100 Ethernet network, the NQ-GA40P3 is
IEEE 802.3bt–compliant and can be powered using Power over Ethernet
(PoE++). The NQ-GA40P3 can direct drive a single 8Ω load and has a bal-
anced line output to drive auxiliary power ampliers, as well as a balanced
line input for auxiliary line-level analog input.
Notice
Every effort was made to ensure that the information in this manual was
complete and accurate at the time of printing; however, all information is
subject to change.
This equipment is not suitable for use in locations where children are likely to be present.
Equipment is intended for use only in a restricted access area.
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Avertissement: pour réduire le risque d’incendie ou de choc électrique, ne pas exposer cet appareil sous la pluie et
l’humidité.
The apparatus shall not be exposed to dripping or splashing and no objects lled with liquids, such as vases, shall
be placed on apparatus.
L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures et aucun objet ne contenant de liquide, tel
qu’un vase, ne doit être placé sur l’objet.
The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, ta-
ble-cloths, curtains, etc.
- il convient que l’aération ne soit pas gênée par l’obstruction des ouvertures d’aéra
No naked ame sources, such as lighted candles, should be placed on the apparatus.
- il convient de ne pas placer sur l’appareil de sources de ammes nues, telles que des bougies allumées
The apparatus should be used in moderate climates.
- si l’appareil est destiné à être utilisé sous un climat tempéré.

2
NQ-GA40P3
Important Safety Information
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Always comply with the following basic safety precautions when installing and using the unit:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Clean only with dry cloth.
6. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
ampliers) that produce heat.
7. Only use attachments/accessories that are specied by the manufacturer.
8. Unplug this apparatus during lightning storms or when unused for long periods of time.
9. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in
any way, such as: the power-supply cord or plug is damaged, liquid has been spilled onto (or objects have fallen
into) the apparatus, the apparatus has been exposed to rain or moisture, or the apparatus does not operate
normally or has been dropped.
10. Maximum operating temperature is 35 °C.
11. The wall mounting height of the NQ-GA40P3 should be equal to or less than two meters. The mounting process
should be conducted by trained professionals with sucient knowledge and tools to reliably t the wall-mount
fasteners.
Installation
To install the NQ-GA40P3 amplier:
1. Attach the desired analog speaker to
the NQ-GA40P3 using the pluggable
connectors provided, where the + and
− terminals connect to the +/− speaker
wires (see “Figure 1” on page 2).
2. If desired, attach an auxiliary amplier
to the NQ-GA40P3 using pins 1 and 2
of the pluggable balanced LINE OUT
connector, taking note of the marked
polarity (+/−). The G shield terminal
can be used if necessary.
3. If desired, line level output from a
preamplier device can be connected
to the NQ-GA40P3 using pins 1 and 2
of the pluggable balanced line connec-
tor, taking note of the marked polarity
(+/−). The G shield terminal can be
used, if necessary.
4. Connect a Cat5-type cable into the
module’s Ethernet port and ensure the
other end of the cable is correctly connected to a PoE switch port on your network.
To balanced input
of auxiliary amplifier.
Use shielded cable.
+
–
8Ω (ohms)
40W (PoE++)
20W (PoE+)
10W (PoE)
Aux Preamplifier
From output of auxiliary
preamplifier. Use shielded
cable.
+G
+
AMP LINE
OUT
−− −+G
Aux Amplifier
LINE
IN
Speaker
Figure 1

3
NQ-GA40P3
Viewing and Understanding LEDs
Two LEDs appear on the front of the . One is labeled POWER and appears amplier chassis
as solid red during initial power up, ashes green during a boot sequence, and appears solid
green when fully booted.
The STATUS LED uses the following indicators to provide information about the module:
• Flashing red: No network connection found.
• Solid blue: The amplier is in an uninitialized state and is not associated to a server. (The server may be in a
discovery mode.)
• Solid green: The amplier is registered to a Nyquist server and is in normal operation.
• Flashing green: The amplier has an IP address but is not registered with the Nyquist server.
• Solid red: The amplier needs to be rebooted or reset so that the Nyquist application can resume.
• Flashing blue: The amplier is updating.
Using the Reset Button
The Reset button allows you to restart the amplier or to reset the amplier’s conguration settings
to the factory default settings.
For more information about resetting conguration settings, refer to the Nyquist NQ-GA40P3 Cong-
uration Guide.
Temperature Indicator
In addition to the LEDs that appear on the actual appliance, a separate temperature status indicator appears on the
module’s web-based user interface. For more information, refer to the Nyquist NQ-GA40P3 Conguration Guide.
Accessories
The PI5660W PoE++ injector can be purchased from Bogen in lieu of using a PoE++–compatible network switch.
Visit www.bogen.com for more information.
Compliance
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Produktspezifikationen
Marke: | Bogen |
Kategorie: | Empfänger |
Modell: | NQ-GA40P3 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Bogen NQ-GA40P3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Empfänger Bogen
1 August 2024
1 August 2024
27 Juli 2024
24 Juli 2024
24 Juli 2024
21 Juli 2024
13 Juli 2024
11 Juli 2024
10 Juni 2024
15 Mai 2024
Bedienungsanleitung Empfänger
- Elipson
- Conrad
- Dreambox
- Raymarine
- BOYA
- Atlona
- Medeli
- Datapath
- Metronic
- Cyrus
- MIPRO
- Bang And Olufsen
- Onkyo
- Denson
- Sunstech
Neueste Bedienungsanleitung für -Kategorien-
16 Juni 2025
16 Juni 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025