Botex NETcon 1-3 Bedienungsanleitung
Botex
Nicht kategorisiert
NETcon 1-3
Lies die bedienungsanleitung für Botex NETcon 1-3 (1 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 29 Personen als hilfreich bewertet und erhielt im Schnitt 4.4 Sterne aus 15 Bewertungen. Hast du eine Frage zu Botex NETcon 1-3 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/1

Thomann GmbH • Hans-Thomann-Straße 1 • 96138 Burgebrach • www.thomann.de • info@thomann.de DocID: 451599_13.01.2020
EN
User manual
This manual contains important information on the safe operation of the product.
Read and follow the safety advice and instructions given. Retain the manual for future
reference. If you pass the product on to others please include this manual.
NETcon 1 3 Art-Net Node–
For the transport and protective packaging, environmentally friendly materials
have been chosen that can be supplied to normal recycling. Ensure that plastic
bags, packaging, etc. are properly disposed of. Do not just dispose of these ma-
terials with your normal household waste, but make sure that they are collected for recy-
cling. Please follow the notes and markings on the packaging.
This product is subject to the European Waste Electrical and Electronic Equip-
ment Directive (WEEE) in its currently valid version. Do not dispose of your old
device with your normal household waste. Dispose of this product through an
approved waste disposal rm or through your local waste facility. Comply with
the rules and regulations that apply in your country. If in doubt, consult your local waste
disposal facility.
Safety instructions
Intended use
This device is used to distribute ArtNet and Ethernet signals. Any other use or use
under other operating conditions is considered to be improper and may result in
personal injury or property damage. No liability will be assumed for damages result-
ing from improper use.
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are
not within reach of babies and young children. Choking hazard! Ensure
that children do not detach any small parts from the product. They could
swallow the pieces and choke! Never let children unattended use electrical devices.
Where to use the product
Never use the product
• in conditions of extreme temperature or humidity
• in extremely dusty or dirty areas
• at locations where the unit can become wet
General handling
• To prevent damage, never use force when handling the product.
• Never immerse the product in water. Just wipe it with a clean dry cloth. Do not use
liquid cleaners such as benzene, thinners or ammable cleaning agents.
Features
• ArtNet / DMX converter
• Bidirectional ArtNet Node for professional requirements
• Conguration via built-in display directly on the device
• RDM capable
• Adjustable DMX repeat rate (10–40Hz)
• For 512 channels / one DMX universe
• Converts either ArtNet to DMX or DMX to ArtNet
• Black metal housing
Technical specications
Connections: 2×Ethernet RJ45 lockable
XLR 3-pin. DMX in and output
Power supply: via supplied power adapter: DC 5V /10W
Protective class: IP20
Dimensions (W×H×D): 167×130×110mm
Weight: 0.34kg
Using the product
Press MODE to enter the following menu, then use UP & DOWN to select the desired entry which you call up with SETUP:
1. IP address
2.x.x.x IP type 1, automatically generated, not editable
IP address setting for ArtNet must be made according to the setting
under IP type (4.).
10.x.x.x IP type 2, automatically generated, not editable
DHCP IP type 3, automatically generated, not editable
192.168.000.008 IP type 4, adjustable by user
2. Subnet mask
255.000.000.000 IP type 1, automatically generated, not editable
Subnet mask setting for ArtNet must be made according to the
setting under IP type (4.).
255.000.000.000 IP type 2, automatically generated, not editable
DHCP IP type 3, automatically generated, not editable
255.255.255.000 IP type, adjustable by user
3. Universe 000 255–ArtNet universe setting must be made according to the setting under
IP type (4.).
4. IP type
2.x.x.x (Auto) IP address, automatically generated, not editable
Species the IP type for ArtNet.
10.x.x.x (Auto) IP address, automatically generated, not editable
DHCP IP address, automatically generated, not editable
Custom IP IP address adjustable by user
5. Unicast address xxx.xxx.xxx.xxx For setting the ArtNet unicast address. The validity of a unicast ad-
dress requires the settings ‘DMX | DIR: IN’ and ‘unicast | ON’.
6. DMX Dir In DMX input, conversion DMX -> ArtNet For setting the ArtNet direction.
Out DMX input, conversion ArtNet -> DMX
7. Unicast
On, (Unicast on)
Mode Master Slave Notes:
• The validity of the unicast setting requires the setting ‘DMX | DIR: IN’.
• ‘XXX’ means ‘value irrelevant’.
• The unicast address of master and IP address is the same as in uni-
cast mode. However, there is one special case, for example, the slave
IP address: 192.168.1.1, master unicast address: In addition to the
setting of 192.168.1.1, it can also be set to 192.168.1.255, where 255
is a general address. The last IP range of the slave is 0-254. Therefore,
we recommend not to use 255 as a special address.
IP address 192.168.1.0 192.168.1.1
Subnet mask 255.255.255.0 255.255.255.0
Universe 0 0
IP type 4) Custom IP 4) Custom IP
Unicast address 192.168.1.1 xxx.xxx.xxx.xxx
DMX Dir OutIn
Unicast On O
O, (Unicast o), Broadcast
Mode Master Slave
IP address 192.168.1.0 192.168.1.1
Subnet mask 255.255.255.0 255.255.255.0
Universe 0 0
IP type 4) Custom IP 4) Custom IP
Unicast address xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx
DMX Dir OutIn
Unicast O O
8. RDM Enable On To enable (On) or disable (O ) the RDM function.
O
9. Frame Rate 10 40(Hz) Sets the DMX repeat rate for ArtNet.–
10. Settings
Lock On Enables (On) or disables (O) automatic display lock. To release the
display lock, keep [Mode] and [Setup] pressed for 3 sec.O
Back light On Enables (On) or disables (O) backlight auto-o function when not
in use.O
Factory Yes Reset to delivery condition.
No
11. Exit To exit the menu.
Produktspezifikationen
Marke: | Botex |
Kategorie: | Nicht kategorisiert |
Modell: | NETcon 1-3 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Botex NETcon 1-3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Botex
21 August 2024
21 August 2024
21 August 2024
20 August 2024
20 August 2024
19 August 2024
18 August 2024
17 August 2024
19 Juni 2023
19 Juni 2023
Bedienungsanleitung Nicht kategorisiert
- Atosa
- Heitronic
- Terraillon
- FCC BBQ
- Brigmton
- Auto Joe
- Kettler
- Victor
- N8WERK
- Lego
- Caberg
- Gastronoma
- MiPow
- IPGARD
- EAS Electric
Neueste Bedienungsanleitung für -Kategorien-
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025