Lies die bedienungsanleitung für Candy FO FPG 201 N (42 Seiten) kostenlos online; sie gehört zur Kategorie Backöfen. Dieses Handbuch wurde von 35 Personen als hilfreich bewertet und erhielt im Schnitt 3.6 Sterne aus 18 Bewertungen. Hast du eine Frage zu Candy FO FPG 201 N oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/42

Connection
An information plaque on the oven indicates the gas with which it has been regulated.
If you have the same gas supply with which the appliance has been regulated, follow
the connection instructions carefully. Otherwise, adapt the oven for the different types
of gas before reading the connection instructions.
Connection instructions - fig. 3
The oven must be connected to the gas mains via a rigid metal pipe or with a flexible
metal tube complying with UNI 9891. The ramp gas pipe fitting and the pipe must be
connected in the following two ways:
1) using a connection without a gasket on the thread (the oven connection is cone-shaped: ISO R 7);
2) interrupting a metal gasket (aluminium, copper, rubber approved for this use); by
way of example, see fig. 3.
WARNING: gas connection via a flexible rubber tube fixed onto the tube holder is
not permitted on a fitted gas oven when it is not possible to inspect the tube.
Attention
On completing the operation, check that there are no gas leaks.
Search for gas leaks using soapy water or equivalent liquids.
NEVER USE A FLAME TO CHECK FOR GAS LEAKS.
Adapting the gas used
The appliance is regulated to operate with the gas indicated on the packaging and the
appliance itself (see technical data plaque).
Fig.3
2)
1)
RAMP GASKET
FLEXIBLE TUBE
41

Technical data
Table 2
Conversion with different gas to the regulation gas used in the factory.
Identical operations for both burners:
• check the oven is disconnected from the electrical power supply
• open the oven door completely
• remove the bottom plate from the oven (fig. 4)
• remove the burner by unscrewing screw “A”
• remove injector “B” and replace it following the instructions shown in table 2 (check
there are no gas leaks on completing the operation)
• reinstall the oven burner
• put the plate back in place
FORNO
Ø Gas injector G30/G31 mm 0,73
Ø Gas injector G20/G31 mm 1,15
Ø Gas bypass G30/G31 mm 0,42
CAT. I3, I2, I2L sealed in factory
CAT. II2H3, II23 for gas G30/G31 screwed tight; for gas G20/G25
regulated for 0,72 kW capacity.
Rated capacity in kW 2,4
Minimum capacity in kW 0,72
Rated consumption of G30 in Kg/h 0,175
Rated consumption of G20 in m3/h 0,228
Rated consumption of G25 in m3/h 0,266
Position of ring nut G30/G31 mm 14
Air regulation (“X”) G20/G25 mm 5
Power supply voltage = 220V AC
Installed power = 1,.5kW (oven with electric grill)
Minimum air exchange needed for combustion is 4,8 m3/h.
Fig.4
42

Regulating the flame
Due to the different characteristics of the gases used, flames with too much or too little air
may be obtained. In this case, regulate the flame as follows (fig. 5):
•loosen screw “C” and turn ring nut “D” to position N for methane or natural gas and
position GPL for liquid propane, ensuring that the mobile index on the ring nut
corresponds with the fixed index on the burner, thereby obtaining the correct flame
(fig. 6)
Minimum regulation
The oven thermostat is equipped with a minimum bypass and it is necessary to alter
regulation if gas type is changed, in the following manner:
• Remove control knob A;
• Remove the two ring nuts on panel B by unscrewing in an anti-clockwise direction.
• Remove control panel C;
• Remove the oven bottom plate (fig. 4);
•Turn on the oven at the highest temperature for at least 10/15 minutes.
•Turn the indexed thermostat knob to 150°C, regulate the by-pass to minimum until a
reduced but stable flame is obtained. This operation should be performed with the
oven door closed.
• Use a screwdriver on the bypass screws. It is sufficient to unscrew the bypass several
turns to regulate the minimum, passing from liquid gas to methane (fig, 7).
•IMPORTANT: after regulating the burner, check the flame remains at the minimum,
by opening and closing the oven door. If the flame goes out, adapt bypass regulation.
• For operation with G30/G31 , the bypass regulation screw must be screwed tight.
On completing regulation, indicate the gas setting on the new plaque.
Fig.6
EXCESS AIR
CORRECT FLAME
INSUFFICIENT AIR
43
Produktspezifikationen
Marke: | Candy |
Kategorie: | Backöfen |
Modell: | FO FPG 201 N |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Candy FO FPG 201 N benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Backöfen Candy
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
6 Juni 2025
28 Mai 2024
27 Mai 2024
26 Mai 2024
Bedienungsanleitung Backöfen
- Team
- Steinberg
- Lakeland
- Viking
- Eurom
- Nesco
- Kunft
- Tristar
- Melchioni
- AEG
- Enders
- Iberna
- Bauknecht
- Summit
- Instant
Neueste Bedienungsanleitung für -Kategorien-
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
16 Juni 2025