Clas Ohlson UNI-T UT133B Bedienungsanleitung
Clas Ohlson
Multimeter
UNI-T UT133B
Lies die bedienungsanleitung für Clas Ohlson UNI-T UT133B (64 Seiten) kostenlos online; sie gehört zur Kategorie Multimeter. Dieses Handbuch wurde von 14 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 7.5 Bewertungen. Hast du eine Frage zu Clas Ohlson UNI-T UT133B oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/64

Eng lishSve nsk aNo r skSuo miDeu ts ch
UNI-T UT133B
Multimeter
Multimeter UNI-T UT133B
UNI-T UT133B multimeter
Yleismittari UNI-T UT133B
Art.no. Model
36-7745 UT133B Ver. 20190705


3
Eng lis h
UNI-T Multimeter
Art.no 36-7745 Model UT133B
Please read theentire instruction manual before using theproduct and then save
it for future reference. We reserve theright for any errors in text or images and any
necessary changes made to technicaldata. In theevent of technical problems
or other queries, please contact our Customer Services (see address details on
theback).
Information about this measuring instrument
This multimeter has been constructed and tested in accordance with therequirements
of Measurement Category III (CAT III) up to 600 V nominal voltage and Pollution
Degree2.
Categorisation
Measuring instruments are classified into categories according to what kind of
electrical environment they can be used in and how safe/protective they are at
withstanding overvoltages.
The Measurement Category of theinstrument will be marked on theratingplate.
The Measurement Category indicates how capable theinstrument is of withstanding
overvoltages which could be dangerous for theuser.
In brief, thecategorisation can be described like this:
• In theevent of asudden overvoltage on thepower grid (atransient energy spike
from alightning strike for example) thedanger is greatest at thepoint where
thepower supply service cable enters abuilding.
• Further in thebuilding, theresistance (impedance) in themains supply
cables increases and connected appliances and devices reduce and divide
theovervoltage. Therefore, theMeasurement Category (also called Overvoltage
Installation Category) of themeasuring instrument indicates which electrical
environment theinstrument is designed to be usedin.
The categories that measuring instruments are classified into are:
• CAT : For measuring electronics and products that have abuilt-in protection I
from overvoltage.
• CAT : For measuring single-phase equipment connected to ahousehold mains II
supply, both through wall sockets and fixed installation.
• CAT : For measuring electrical wiring installed in buildings. Examples are III
measurements on fixed installation cables and hard-wired appliances, socket
outlets, circuit breakers and distribution boards. Three-phase distribution (all
supply cables and 3-phase equipment, machines and appliances).
• CAT : Three-phase at theutility connection and any outdoor conductors.IV
This multimeter is rated as CAT III and is approved for measuring voltages up to
600V on single-phase products. Thismultimeter must not be used for measuring
three-phase equipment, three-phase cables or distribution boards even if
thenominal voltage is not higher than 600V.
Produktspezifikationen
Marke: | Clas Ohlson |
Kategorie: | Multimeter |
Modell: | UNI-T UT133B |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Clas Ohlson UNI-T UT133B benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter Clas Ohlson
21 August 2024
20 August 2024
18 August 2024
5 August 2024
Bedienungsanleitung Multimeter
- Caltek
- JUNG
- Multimetrix
- Steren
- Abus
- Beha-Amprobe
- Voltcraft
- Megger
- Micronta
- FERM
- PCE Instruments
- Brandson
- Klein Tools
- Workzone
- Enovalab
Neueste Bedienungsanleitung für -Kategorien-
9 Juni 2025
8 Juni 2025
8 Juni 2025
7 Juni 2025
4 Juni 2025
31 Mai 2025
31 Mai 2025
30 Mai 2025
3 Dezember 2024
2 Dezember 2024