Draper 12442 Bedienungsanleitung

Draper Messung 12442

Lies die bedienungsanleitung für Draper 12442 (4 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 7 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 4 Bewertungen. Hast du eine Frage zu Draper 12442 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/4
EN
Original Instructions
Version 1 June 2023
12442
DIGITAL
SOUND LEVEL METER
Permissible ambient conditions:
Temperature Humidity
(-4 to +140°F)
(-4 to +140°F)
Dimensions: W 56 × H 144 × D 30.5mm
Weight (with batteries): 123.5g
3. Health and Safety Information
Important: Read all the Health and Safety instructions
before attempting to use this product.
• Use this product ONLY as instructed in this manual.
• DO NOT attempt to open, dismantle or modify this
product in any way.
• Before every use, inspect the device for missing,
broken, loose or corroded parts and battery leakage.
DO NOT use this product if it is damaged in any
way; contact Draper Tools to discuss repair and
replacement options.
If battery acid comes into contact with your skin,
wash it o immediately with plenty of clean water.
If battery acid comes into contact with your eyes,
ush them with plenty of clean water and seek
immediate medical attention.
• DO NOT expose this product to liquids or wet
environments.
• DO NOT use this product in environments in which
dust, steam or smoke are present as this may interfere
with the readings.
• DO NOT use this device in environments that exhibit or
are aected by strong magnetic elds.
• DO NOT use this product if it exhibits abnormal
behaviour and have it checked by a qualied and
authorised technician before next use.
• Keep a lose but rm grip on the device and hold it as
steady as possible as vibrations may aect the
measurements recorded.
• DO NOT abuse, mutilate or burn the battery.
• Keep this product out of reach of children.
Read this manual in full before using this product and
retain it for future use. Always use the latest version of the
manual. Please visit for the drapertools.com/manuals
latest version.
1. Intended Use
This product is a hand-held device designed to measure
sound levels in a given environment. An indication of
temperature is also shown. This device is best used for
measuring ambient noise. Any other application beyond
the conditions established for use will be considered
misuse. Draper Tools accepts no responsibility for
improper use of this product.
Part of our core range, this product is suitable for regular
use by enthusiasts and tradespersons alike.
2. Specication
Stock No.: 12442
Part No.: 180-DSLM-1
Sound measurement
Measurement range: 35135dB
Dynamic rage: 50dB
Frequency range: 31.58,000Hz
Accuracy: ±2.0dB
Resolution: 0.1
Frequency weighting: A-weighted
Time weighting: 0.125s (Fast mode) /1.0s (Slow mode)
Microphone: 1 2" electrets condenser microphone
Temperatre measurement
Measurement range : -20 to +70°C
Accuracy : ±1.5°C / ±2.7°F
Resolution : 0.1
Operating time: Up to 60 hours
Batteries: 3 × 1.5V AAA (not supplied)
4. Identication
4.1 Product Overview
(1)
(6) (5) (3)(7)
(2)
(8)
(4)
(1) Battery compartment
(2) Display
(3) Hold button
(4) Microphone
(5) Min/max button
(6) Power button
(7) Update speed button
(8) Wind shielding microphone cover
Please visit for our full range of drapertools.com
accessories and consumables.
4.2 Display Overview
(9)(20)
(17) (11) (12) (14) (20)(18)
(19)
(13) (15) (16) (10)
(9) Auto-o indicator
(10) Battery level indicator
(11) Fast update speed indicator
(12) High sound level indicator
(13) Hold data indicator
(14) Low sound level indicator
(15) Max value indicator
(16) Min value indicator
(17) Slow update speed indicator
(18) Sound level value
(19) Temperature unit indicator
(20) Temperature value
(20) Frequency weighting icon
5. Operation
5.1 Installing Batteries
This product requires 3 × 1.5V AAA batteries (not
supplied). To install the batteries, slide the battery
compartment cover (1) down and away from the back of
the device and insert the batteries according to the
correct polarity.
5.2 Switching On and Basic Operation
To switch on the device, press the power button (6). The
device performs a diagnostics check during startup for
approximately two seconds before readings are shown on
the display.
Stand in the position to be measured and direct the
microphone (4) toward the source of the sound. The top
end of the microphone is the most receptive to sound and
will deliver the most accurate readings.
Avoid adjusting your grip, moving the device and creating
other audible interference when taking a sound level
measurement. Keep in mind that low-level sound readings
may be aected by sounds generated by the operator.
Important: Ensure that the foam windshield is installed
onto the microphone to reduce interference caused by
wind or air across the face of the microphone. The
windshield slides easily onto the microphone.
Important: Take several measurements in the location to
ensure that the readings are consistent and accurate.
The device begins measuring sound levels and temperature
immediately upon loading and the readings are indicated
on the display. Sound level readings are updated according
to the update speed selected. Temperature readings are
updated every 300ms.
To switch o the device, press the power button. This resets
the device, including any overload warnings.
5.3 Freezing the Display
The current readings can be held on the display by pressing
the hold button (3). The hold data indicator (13) illuminates
to show that the display has been frozen.
Important: While data is held on the display, no other
measurements are taken.
To resume measurements, press the hold button again. The
hold data indicator is hidden and the display updates in
real-time.
5.4 Maximum and Minimum Values
The display can be set to show the maximum or minimum
value recorded for both sound levels and temperature
during an active session.
Press the min/max button to display the maximum value
recorded. Each subsequent press of the min/max button (5)
alternates between the highest and lowest values recorded
since the device was switched on. The max (15) or min (16)
value indicators illuminate as appropriate to identify the
value shown on the display.
Important: While min/max mode is active, no other
measurements are displayed unless they exceed the min or
max reading currently shown on the screen. These new
readings are then locked until they are surpassed by new
data.
To exit min/max display mode, press and hold the min/max
button for three seconds.
5.5 Time-Weighting Modes
The device can be set to display a real-time sound level
reading that updates every 125ms (fast update mode) or to
display an average of the level measured over the course of
every 1s (slow update mode).
Use fast mode to detect peaks in sound levels that occur
very quickly. Use slow mode for more consistent sound
environments.
To switch between update speed modes, press the update
indicators illuminate as appropriate according to the
enabled mode.
5.6 High- and Low-Level Indicators
While the measured sound level remains lower than 100dB,
the low sound level indicator (14) is illuminated.
If the sound level rises above 100dB, the high sound level
indicator (12) illuminates until the level drops.
5.7 Temperature Reading Units
The unit of the temperature reading can be changed during
startup.
Important: Ensure the correct unit of measurement for
temperature is enabled before capturing meaningful
readings as all readings are lost when the device is
switched o.
While the device is o, press and hold the hold button (3).
Keeping the hold button depressed, also press the power
button (6) to switch on the device. The device will launch
with the other temperature units enabled.
The default unit for temperature measurement is degrees
Celsius.
5.8 Automatic Switch-O
By default, the device is congured to power o
automatically after approximately 15 minutes of inactivity.
If automatic switch-o function is enabled, the auto-o
indicator (9) is illuminated on the device display.
To disable the automatic switch-o function, press and
hold the min/max button (5) while the device is o and,
keeping the min/max button depressed, also press the
power button (6) to switch on the device. The device will
launch with the function disabled.
Important: If automatic switch-o is disabled, this applies
only to the current active session. Automatic switch-o is
automatically enabled the next time that the device is
switched on.
Important: If automatic switch-o is disabled, the device
can only be powered down by pressing the power button.


Produktspezifikationen

Marke: Draper
Kategorie: Messung
Modell: 12442

Brauchst du Hilfe?

Wenn Sie Hilfe mit Draper 12442 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten