Draper 47808 Bedienungsanleitung
Lies die bedienungsanleitung für Draper 47808 (4 Seiten) kostenlos online; sie gehört zur Kategorie Pumpe. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Draper 47808 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

LEVER ACTION
BARREL
PUMP
47808
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE
SAFE AND EFFECTIVE USE OF THIS PRODUCT.
INSTRUCTIONS
These instructions accompanying the product are the original instructions. This document is part of the product,
keep it for the life of the product passing it on to any subsequent holder of the product. Read all these
instructions before assembling, operating or maintaining this product.
This manual has been compiled by Draper Tools describing the purpose for which the product has been
designed, and contains all the necessary information to ensure its correct and safe use. By following all the
general safety instructions contained in this manual, it will ensure both product and operator safety, together
with longer life of the product itself.
All photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the
product.
Whilst every effort has been made to ensure the accuracy of information contained in this manual, the Draper
Tools policy of continuous improvement determines the right to make modifications without prior warning.

- 2 -
1. INTRODUCTION
1.1 SCOPE
This Lever Action Barrel Pump is a hand operated heavy duty pump designed to transfer oil
based fluids, heating oils, motor oils, diesel oil, kerosene, heavy & light oils
The pump comes complete with self adjusting telescopic suction tube, curved metal spout, and
1½" & 2" bung nut.
2. HEALTH AND SAFETY INFORMATION
2.1 GENERAL SAFETY INFORMATION
To ensure safe and efficient operation, it is essential to read and follow each of these warnings
and precautions.
1. Improper use or installation of this product can cause serious bodily injury or death.
2. Do NOT smoke near pump or use pump near an open flame. Fire could result.
3. When pumping flammable liquids, all equipment must be grounded to prevent the
accumulation of static electricity which may ignite vapours or gases.
4. The pump and containers should be connected using bonding clamps or clips and a
conductive wire no smaller than 12 gauge. A secure and positive metal-to-metal contact must
be made. The other end of the wire should be attached to a good ground, such as a steel
building column or water pipe.
Warning: Leave handle in upright position when not in use.
1.2 SPECIFICATION
Stock No’s. ............................................................................................................................... 47808
Part No’s. ................................................................................................................................. BP/G
Barrel size ..................................................................................................... 1½" & 2" bung adaptor
Delivery rate ....................................................................................... up to 300ml(10oz. per stroke)
Non return seal.......................................................................................................................... NBR
Wetted components................................................................ Steel, Aluminium, Zinc, Brass & NBR.
Recommended use: ..
Oil base fluids, heating oils, motor oils, diesel oil, kerosene, heavy & light oils.
Do not use: ............... Water based fluids, solvents, acid, antifreeze or fluids that cause corrosion.

- 3 -
3. TECHNICAL DESCRIPTION
4. ASSEMBLY
4.1 ASSEMBLY
1. Screw the suction tube assembly into the bung nut . Tighten the connection securely to
eliminate any air leaks.
2. Screw the delivery spout nut (part of the spout) onto the pump head. Tighten securely to
eliminate any possibility of leakage.
3. Extend the telescopic suction pipe little longer than the height of the drum.
4. Screw the pump into the drum’s bung. Tighten the pump assembly securely by grasping the
pump body and rotating.
5. Pull the plunger rod of piston sub assembly up and attach the lever handle to the piston
rod using the pivot pin and retainer clip .
Pivot Pin & retainer clip.
Plunger rod.
Lever handle.
Delivery spout
Compression nut.
Spout nut.
Pump head.
Rubber grip.
Pump body.
Bung nut.
Suction tube assembly.
3.1 IDENTIFICATION
Produktspezifikationen
Marke: | Draper |
Kategorie: | Pumpe |
Modell: | 47808 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Draper 47808 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Pumpe Draper
11 Juli 2025
11 Juli 2025
Bedienungsanleitung Pumpe
- Ultimate Speed
- Telestar
- Gardena
- Rule
- Superior Pump
- Pontec
- Osram
- Hyundai
- Germania
- Danfoss
- Lavorwash
- Hayward
- Zipper
- Fluke
- Outwell
Neueste Bedienungsanleitung für -Kategorien-
11 Juli 2025
11 Juli 2025
11 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025