Elation DMX Branch 419 Bedienungsanleitung
Elation
Beleuchtung
DMX Branch 419
Lies die bedienungsanleitung für Elation DMX Branch 419 (4 Seiten) kostenlos online; sie gehört zur Kategorie Beleuchtung. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.5 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Elation DMX Branch 419 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

Elation Professional
®
4295 Charter Street
Los Angeles Ca. 90058
www.elationlighting.com
Revised 5/02
©
Elation Professional
® -
www.elationlighting.com - DMX Branch 419™ User Manual Page 2
Introduction:
To optimize the performance of this product, please
read these operating instructions carefully to familiarize yourself with
the basic operations of this unit. The DMX Branch 419™ is a 4-way
DMX signal distributor by Elation Professional
®
. This unit allows the
user to split and boost a DMX signal anywhere in a DMX signal path,
a function that is typically not recommended without the use of device
similar to this one. The unit has been durably constructed in a rack
mount chassis for convenient rackmount storage.
Unpacking:
Thank you for purchasing the DMX Branch 419™
by
Elation Professional
®
.
Every DMX Branch 419™ has been thoroughly
tested and has been shipped in perfect operating condition. Carefully
check the shipping carton for damage that may have occurred during
shipping. If the carton appears to be damaged, carefully inspect your
unit for damage and be sure all accessories necessary to operate the
unit have arrived intact. In the event damage has been found or parts
are missing, please contact our toll free customer support number for
further instructions. Please do not return this unit to your dealer with-
out first contacting customer support at the number listed below.
Customer Support:
Elation Professional
®
provides a customer sup-
port line, to provide set up help and to answer any question should
you encounter problems during your set up or initial operation. You
may also visit us on the web at www.elationlighting.com for any com-
ments or suggestions.
For service related issue please contact Elation
Professional
®
Service Hours are Monday through Friday 9:00 a.m. to
5:00 p.m. Pacific Standard Time.
Voice:
(323) 582-3322
Fax:
(323) 582-3108
E-mail:
support@elationlighting.com
Warning!
To prevent or reduce the risk of electrical shock or fire, do
not expose this unit to rain or moisture.
Caution!
There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures
warranty.
Please do not discard the shipping carton in the trash. Please recycle
when ever possible.
DMX Branch 419™ Introduction

DMX Branch 419™ Introduction DMX Branch 419™ Safety Precautions
Safety Issues:
This unit may blow a fuse if the maximum allotted load
of 0.5 amps is reached. If the fuse needs replacement, always replace
the fuse with same exact type that was removed, unless otherwise
instructed by an authorized Elation
®
service technician. Use of a dif-
ferent type fuse from that which is recommended may cause fire or
electric shock and will void the manufactures warranty.
To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
Do not spill water or other liquids into or on to your unit
Do not attempt to operate this unit if the power cord has been
frayed or broken
Do not attempt to remove or break off the ground prong from the
electrical cord. This prong is used to reduce the risk of electrical
shock and re in case of an internal short
Disconnect from main power before making any type of connection
•
Do not remove the cover under any conditions. There are no user
serviceable parts inside
Never plug this unit in to a dimmer pack
Always be sure to mount this unit in an area that will allow proper
ventilation.
Do not attempt to operate this unit, if it becomes damaged
This unit is intended for indoor use only, use of this product out-
doors voids all warranties
During long periods of non-use, disconnect the unit’s main power
Always mount this unit in safe and stable matter
Power cords should be routed so they are not likely to be walked
on, pinched by items placed upon or against them.
• Cleaning -The fixture should be cleaned only as recommended by
the manufacturer. See page 7 for cleaning details
Heat -The appliance should be situated away from heat sources
such as radiators, heat registers, stoves, or other appliances (in-
cluding amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
C. The appliance has been exposed to rain or water.
D. The fixture does not appear to operate normally or exhibits a
marked change in performance.
•
Quality Neutrik Connections
•
Easy Fuse Replacement
Light Weight, Rackmount Case Design
Built-In LED Indicators
Terminate/Link Function Switch
•
3-pin and 5-pin XLR Connectors for Universal Connectivity
4 Channel Output
Parallel Link Out Connectors
DMX Branch 419™ Warranty Registration
The DMX Branch 419™ carries a two year (730 days) limited war-
ranty. Please fill out the enclosed warranty card to validate your pur-
chase. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) num-
ber. The R.A. number must be clearly written on the outside of the
return package. A brief description of the problem as well as the R.A.
number must also be written down on a piece of paper and included
in the shipping container. If the unit is under warranty, you must pro-
vide a copy of your proof of purchase invoice. You may obtain a R.A.
number by contacting customer support at (323)
582-3322, extension
170.
DMX Branch 419™ Fuse Replacement
Caution:
Always replace with the exact same type fuse, unless oth-
erwise specified by an authorized Elation
®
technician. Replacing with
anything other than the specified part can damage your unit and will
void your manufactures warranty.
Warning:
If you continue to blow fuses, STOP using the unit.
Contact customer support for further instructions, you may have to
return the unit for servicing. Continuing to use the unit may cause
serious damage.
Fuse Replacement:
Disconnect the unit’s main power. Insert a standard flat head screw
driver in to the fuse holder housing. Turn the screwdriver in counter-
clockwise direction to remove the fuse holder. Remove the old fuse
and discard it, replace the fuse with the same type. Insert the fuse
holder back into it’s housing and turn in clockwise direction to lock
the holder in place.
©
Elation Professiona
® -
www.elationlighting.com - DMX Branch 419™ User Manual Page 4
©
Elation Professional
® -
www.elationlighting.com - DMX Branch 419™ User Manual Page 3

DMX Branch 419™ Cleaning
Unit Cleaning:
Due to fog residue, smoke, and dust cleaning the exterior of the case
may become necessary. Please follow the guidelines printed below
for proper cleaning.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Always be sure to dry all parts completely before plugging
the unit back in.
DMX Branch 419™ Operation
DMX Branch 419™ Controls and Functions
6
7
5
4
3
9
8
2
1. Link Out / Terminate Selector -
This switch is primarily meant for
troubleshooting. When the switch is in the “Terminate” (left) position,
The Parallel Link Output is turned off. You cannot link any more units.
When the switch is in the “Link Out” position, it allows for signal of the
parallel DMX output for linking more DMX Branch-419 units.
2. Parallel DMX Output -
These Outputs are used to link out to a sec-
ond DMX Branch-419. To be used for linking only.
3. Boosted DMX Output Section -
The four DMX output channels are
completely Optically and Electronically Isolated and feature an inde-
pendent driver that boosts the DMX signal.
4. Power Switch -
This is the main power switch and turns power on
and off. When power is off the Parallel DMX Output Jacks (2) may be
used but the
Boosted DMX Output Section (3)
will not function.
5. DMX Input -
These jacks are used to capture an incoming DMX
signal from either a DMX controller or any other DMX device sending
a DMX output signal.
6. Green DATA (-) LED -
Indicates that pin 2(-) polar negative, is mak-
ing proper connection through out the data stream of the given out-
put.
The DMX Branch 419 is a 4-way DMX distributor with a 3-pin and 5-pin
XLR input jack. Be sure to never connect more than one input source
to this unit at a time. Two input jacks have been provided for universal
connectivity only. This unit takes the incoming DMX signal and safely
boost and splits the signal into four separate output channels. Each
output channel and the input channel are completely electronically
isolated from each other to avoid unwanted signal crosstalk that can
cause erratic behavior.
All four output channels have independent output drivers. A 3-pin and
5-pin output connector is provided per a channel allowing the output of
each channel to double when using both connectors at once.
7. Red DATA (+) LED -
Indicates that pin 3(+) polar positive, is making
proper connection through out the data stream of the given output.
8. Fuse Holder -
This unit is used to house the protective overload
fuse. The fuse type is a GMA 0.5A 250V 5x20mm always replace with
the same type fuse. To replace the fuse, please see the fuse replace-
ment section on page 4.
9. Power Input:
This device is designed to accept an AC signal of ei-
ther 120v~50/60Hz or 220v~50Hz, be sure the power supply for your
unit matches that of printed label on the unit.
DMX Branch 419™ Controls and Functions
©
Elation Professional
® -
www.elationlighting.com - DMX Branch 419™ User Manual Page 6
©
Elation Professional
® -
www.elationlighting.com - DMX Branch 419™ User Manual Page 5
Produktspezifikationen
Marke: | Elation |
Kategorie: | Beleuchtung |
Modell: | DMX Branch 419 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Elation DMX Branch 419 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Beleuchtung Elation
4 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
Bedienungsanleitung Beleuchtung
- Hella
- Luxli
- Lucide
- Prixton
- Globaltronics
- Frandsen
- Enttec
- Laserworld
- JBL
- Viessmann
- Ibiza Light
- Ikan
- Fun Generation
- Sengled
- Auer Signal
Neueste Bedienungsanleitung für -Kategorien-
4 September 2025
4 September 2025
4 September 2025
4 September 2025
4 September 2025
4 September 2025
4 September 2025
4 September 2025
3 September 2025
3 September 2025