Extech 445703 Bedienungsanleitung
Lies die bedienungsanleitung für Extech 445703 (1 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 33 Personen als hilfreich bewertet und erhielt im Schnitt 5.0 Sterne aus 7 Bewertungen. Hast du eine Frage zu Extech 445703 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/1

445703en--US_V2.653 /2
Big Digit Hygro-Thermometer
Model 445703 - User Manual
INTRODUCTION
Congratulations on your purchase of Extech’s Big Digit Hygro-Thermometer. This professional meter, with proper care, will provide years of safe
reliable service.
OPERATION
1.Open the battery compartment by pushing the cover on the rear of the instrument downward as indicated by the arrow. Remove the battery
safety strip and the protective cover on the LCD display. The instrument is now ready for use.
2.The temperature units can be selected via the switch located on the rear of the instrument.
3.The upper display indicates the temperature in degrees C or F. The lower display indicates relative humidity in %.
4.Displaying the minimum and maximum values.
a. Press the MAX/MIN button. The highest value measured since the Reset button was last pressed appears on the display.
b. Press the MAX/MIN button again to display the lowest value measured since the Reset button was last pressed.
c. Press the MAX/MIN button again to return to normal display operation.
5.Resetting (clearing) the MAX/MIN memory.
6.Press and hold the RESET button for 1 second while in the MAX/MIN display mode to clear the memory and start recording new max/min
values.
7.The unit can be wall-mounted or placed on a flat surface using the foldout footing.
8.The low battery flag will appear on the display when the battery voltage is low. Replace the battery when this occurs.
SPECIFICATIONS
Temperature -10 to 60°C ±1.0°C within -10°C to 50°C
14 to 140°F ±1.8°F within 14°F to 122°F
Humidity 10% to 99% ±5% RH within 25% to 85% RH and 0 to 50°C or 32 to 122°F
Battery One (1) 1.5V 'AAA' cell
Size / Weight 109 x 99 x 20mm (4.3 x 3.9 x 0.78”) /169g (6 oz.)
BATTERY REPLACEMENT
Open the battery compartment by sliding the battery cover on the rear of the instrument downward as indicated by the arrow. Replace the
1.5V ‘AAA’ battery and replace the cover.
You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the household
garbage is prohibited!
You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold!
Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle
Two-year Warranty
Teledyne FLIR warrants this Extech brandinstrument to be free of defects in parts and workmanship for from date of shipment (a two years
six-month limited warranty applies to sensors and cables). To view the full warranty text please visit:
http://www.extech.com/support/warranties.
Contact Customer Support
Customer Support Telephone List: https://support.flir.com/contact
Calibration, Repair, and Returns: [email protected]
Technical Support: https://support.flir.com
Copyright 2023 Teledyne FLIR Commercial Systems, Inc. ©
All rights reserved including the right of reproduction in whole or in part in any form
www.extech.com
This document does not contain any export-controlled information
Produktspezifikationen
| Marke: | Extech |
| Kategorie: | Messung |
| Modell: | 445703 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Extech 445703 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Extech
5 Januar 2026
5 Januar 2026
4 Januar 2026
4 Januar 2026
4 Januar 2026
8 Dezember 2025
8 Dezember 2025
8 Dezember 2025
8 Dezember 2025
7 Dezember 2025
Bedienungsanleitung Messung
Neueste Bedienungsanleitung für -Kategorien-
1 April 2026
31 März 2026
31 März 2026
31 März 2026
30 März 2026
30 März 2026
30 März 2026
30 März 2026
29 März 2026
29 März 2026