Lies die bedienungsanleitung für Extech PD20 (1 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 18 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 9.5 Bewertungen. Hast du eine Frage zu Extech PD20 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/1

PD20‐en‐US_V1.09/14
1
2
5
6
3
4
ModelPD20‐Thermo‐Pedometer
Safety
Keep the PD20 and the battery out of reach of children
Don’t expose PD20 to liquid, fire, shock or vibration
Please replace the battery as soon as it loses power
Wearprotectivegearwhenhandling leaking batteries
Description
1. Display
2. RECbutton
3. ON‐OFFbutton
4. Eyeletforlanyard
5. MODE
button
6. Set°C/°Fbutton
BatterydoorandResetButton
Locatedon ofback PD20
BasicOperation
Peel the protective foil off of the display.
Open the battery compartment (using a coin), remove the
insulationstrip,andclosethebatterydoor.ThePD20will
powerON. replaceIfnot, the battery.
‘0 STEP’ will show at the top of the display and the time
will
show at the bottom when the unit is ON.
Press ‐ and hold the ON OFF button to switch OFF. Press and
holdtheON ON‐OFFbuttontoswitch again.
The ‐ PD20 enters power saver mode after 10 minutes of
inactivity(onlythetimeappearsonthedisplay).
To
deactivatepower‐savermode:movetheinstrument
slightly;theSTEP display willappear.
SettingsMode
1. PressandholdtheSET°C/°Fbuttonfor 3 seconds.
2. °C °For with MODEAM/PMwillflash.Press
tochange
units.PressSET°C/°Fagaintoconfirm.
3. the Thetimewillappearwith hourdigitflashing.PressREC
orMODE
toincrease/decreasethe the hour. Press SET
°C/°Fbuttontoconfirm.
4. Minuteswillbeginflashing.PressREC
orMODE
to
increase/decreasetheminutesthenpressSET°C/°F.
5. LCD Thesteplengthwillappearonthe (default60cm /
23.5in).PressREC
orMODE
toincrease/decreasethe
steplength(1cm).PressSET°C/°Ftoconfirm.
6. the Theweight(default 110lbs. / 50kg)willappearon LCD.
PressREC
orMODE
toincrease/decreasetheweight
(1lb.).PresstheSET°C/°Fbuttontoconfirm.
STANDARDStepCounting
PressandholdMODE for 3 secondsto toresetthe display ‘0
STEP’.Note: nonThePD20ignores ‐walkingmotion.Stepswill
be severalregisteredonthe after display regularstepsare
detected.
TemperatureIndication
Pressandrelease SETthe °C/°Fbuttonto display the actual
temperatureforfiveseconds.
DisplayModes
Use mode:the theMODE buttontoselect display
Calorie consumption/fat burn: KCAL and BGM or OZ
Distance covered in kilometers (KM) or miles (M) and the
timetaken(inhours/minutesatbottom of display)
Averagespeedkilometersormilesperhour
PressMODEto toreturn normalmode(STEP
andtime).
STANDARD 7 ‐DayStorage
PressRECand‘DAYSAGO:1’ thewillappearon display.Use
RECtoselectthe thedesiredday(DAYSAGO ‐1 7).Once
desireddayisreached,pressMODE toselect:
Calorie consumption/fat burn: KCAL and BGM or OZ
Distance covered in KM or miles (M) and the time taken (in
hoursandminutesshownatbottomofdisplay)
AveragespeedinKM/HorM/H
Note: memoryTheday’sdataisstoredin aftermidnight.The
currenttimeand‘0STEP’appearonthe thedisplay; selected
settingsare retained (seeSettings Mode).
CONTINUOUSStepCounting
ThePD20recordstheno.ofsteps walked continuously
withoutrestinglongerthan 5 minutes.Stopping > 5 minutes
starts a newsession(countingfromzero again). Onlythe
largeststepsessionoftheday andwillbeshown stored.See
instructionsbelow:
1. Hold REC
for displays) 3 seconds(‘CONTSTEP’
2. 7) PressREC▲toshow ‐7 day‐CS‐storage(DAYSAGO ‐1
3. the the Whenon appropriatedaypressMODE▼tocycle
following displays:
Calorie consumption and fat burned (KCAL and GM or
OZ).
Distance and time (KM or M and the time in hours and
minutes).
Average speed (KM/H or M/H)
4. the data Aftermidnight, current willbestored
TOTAL ‐7 DayStepStorage
TheTotalStepStoragerecords total of no. stepswalked.This
feature regularcomesafterthe ‐7 day when‐storage feature
steppingthroughthefeatures.
‘A’ appears on right side of the display in this mode.
When the total accumulated steps exceeds 5 digits
(>99999steps),theleastsignificant
digit displays on the
secondline.
The ‐ ‐basic operation is the same as the standard 7 day
storage previousfeature explained inthe section.
Press and hold MODE ▼to clear the storage and restart
countingfrom zero.
Note:ContinuousStepisanimportantindicator showing the
intensity of
a walking exercise. Doctors prefer this number
overthetotalsteps walked perday.
RESETButton(rear)
Toreturntheunittoitsfactorydefault state, use a paperclip
orpintopresstherearRESETbutton.
AttachingthePD20
Belt: Attach the PD20 with the pouch clip on a waistband or belt.
Around the neck: Thread a lanyard throughthe PD20 eyelet and
make a secureknot.
Maintenance
Clean soft DothePD20with adampcloth. notusesolventsor
abrasives.Ifthe theunitdoesnotwork properly, pleasereset
instrumentorreplacetheCR2032battery(rear).
Specifications
Max.Numberofsteps ‐0 99,999
Max.Distance 0‐624.99mi(0‐999.99km)
Max.Speed 0‐6.25mi/h(0‐10km/h)
Max.Calorieconsumption 0‐99,999kcal
Max.Fatburned 0‐35.9oz.(0‐999.9g)
OperatingTemperature14°F 122°F‐ ‐( 10°C 50°C)‐
Step count accuracy ±50per1000steps
Batterypower
1 x CR2032buttoncell
Dimensions2.20 0.63 3.15 80 x xin(56 x 16 xmm)
Weight 1.20oz.(34g)[instrumentonly]
Copyright ©2014FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorin inpart anyform
www.extech.com
Produktspezifikationen
| Marke: | Extech |
| Kategorie: | Messung |
| Modell: | PD20 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Extech PD20 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Extech
5 Januar 2026
5 Januar 2026
4 Januar 2026
4 Januar 2026
4 Januar 2026
8 Dezember 2025
8 Dezember 2025
8 Dezember 2025
8 Dezember 2025
7 Dezember 2025
Bedienungsanleitung Messung
- INFICON
- Camille Bauer
- Eltako
- VirtuFit
- Daytronic
- Ermenrich
- Wiha
- Techno Line
- CIRCUTOR
- Stelzner
- Einhell
- Sanwa
- SKS
- Schneider
- Meec Tools
Neueste Bedienungsanleitung für -Kategorien-
20 Januar 2026
20 Januar 2026
20 Januar 2026
20 Januar 2026
20 Januar 2026
19 Januar 2026
19 Januar 2026
19 Januar 2026
19 Januar 2026
18 Januar 2026