Lies die bedienungsanleitung für Festo CRDSNU-16 (2 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 14 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 7.5 Bewertungen. Hast du eine Frage zu Festo CRDSNU-16 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/2
Translation of the original instructions
© 2021 all rights reserved to Festo SE & Co. KG
1Applicable documents
All available documents for the product www.festo.com/sp.è
2Safety
2.1Safety Instructions
Take into consideration the ambient conditions at the location of use.
Only use the product in original status without unauthorised modifications.
Store the product in a cool, dry, UV-protected and corrosion-protected envir-
onment. Ensure that storage times are kept to a minimum.
Prior to mounting, installation and maintenance work: Switch off compressed
air supply and secure it from being switched back on.
Observe tightening torques. Unless otherwise specified, the tolerance is
±20%.
2.2Intended use
The product is intended for the transport of loads.
2.3Training of skilled personnel
Installation, commissioning, maintenance and disassembly should only be con-
ducted by qualified personnel.
3Further information
Accessories www.festo.com/catalogue.è
Spare parts www.festo.com/spareparts.è
4Service
Contact your regional Festo contact person if you have technical questions
èwww.festo.com.
5Product overview
5.1Function
The piston rod moves outwards when the cylinder chamber is pressurised. The
advanced piston rod is retracted as follows:
For double-acting cylinders, by pressurising the other cylinder chamber.
The cylinder force during advance and return is:
different with piston rod at one end.
The position of the piston can be detected by proximity switches.
5.2Design
1
Male thread on the piston rod for
mounting the payload
2
Male thread on the bearing cap for
mounting
3
Supply ports in the bearing/end
cap
4
Cross hole for mounting
Fig. 1 Sample illustration CRDSNU
5.3Mounting
Handle the cylinder so as to avoid any damage to the cylinder barrel and pis-
ton rod.
Observe the following points:
parallel mounting when using external guides
installation without distortion
Compliance with the permissible loads www.festo.com/catalogueè
Observe tightening torque of lock nuts on the male thread.2
Size121620253240506380100
Tightening torque
on the bearing cap
[Nm]151540406080100100550550
Tab. 1 Tightening torques on the bearing cap
Avoid mechanical alignment inaccuracies between the piston rod and an
external guide using one of the following measures:
absolutely precise alignment (general)
use of a self-aligning rod coupler FK
use of a guide unit FEN with compensating coupling
A rigid coupling impairs the service life and function of the cylinder.
5.4Mounting Accessories
In the case of a large payload, high piston speed or when using quick exhaust
valves:
Use suitable shock absorbers or external stops.
To prevent the payload from sliding down suddenly in the event of an air supply
failure in a horizontal or sloping mounting position:
Use piloted check valves.
To set the speed:
Use one-way flow control valves in the following supply ports:
For single-acting cylinders: GRLZ (supply air)
For double-acting cylinders: GRLA (exhaust air)
The one-way flow control valves are screwed directly into the supply ports. Use of
other accessories with a screw-in depth that is too long will damage the cushion-
ing piston.
For position sensing with proximity sensors:
Use proximity sensors with mounting kit.
Avoid external influence caused by magnetic or ferritic parts in the vicinity of
the proximity sensors (spacing10mm).³
6Installation
6.1Pneumatic Installation
Connect tubing to supply ports.
7Commissioning
7.1Preparation
Pressurise the system slowly. A soft start valve is used for gradual start-up
pressurisationwww.festo.com/catalogue. è
With medium or large payloads or at high speeds:
Use sufficiently large arrester fixtures. The product will tolerate the maximum
velocities and payloads without external arrester fixtures
èwww.festo.com/catalogue
8143197
CRDSNU
Round cylinder
8143197
2021-01c
[8143199]
Operating instructions
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com


Produktspezifikationen

Marke: Festo
Kategorie: Nicht kategorisiert
Modell: CRDSNU-16

Brauchst du Hilfe?

Wenn Sie Hilfe mit Festo CRDSNU-16 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten