Gossen Metrawatt KE7200 Bedienungsanleitung
Gossen Metrawatt
Messgeräte
KE7200
Lies die bedienungsanleitung für Gossen Metrawatt KE7200 (28 Seiten) kostenlos online; sie gehört zur Kategorie Messgeräte. Dieses Handbuch wurde von 34 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 17.5 Bewertungen. Hast du eine Frage zu Gossen Metrawatt KE7200 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/28

Network and Cable Tester LAN
KE7200
KE7200 PRO Kit
R Uemote Nit
KE7010
KE7010 Kit
KE7010 PRO Kit
Operating Instructions
POWERED BY GOSSEN METRAWATT
3-447-204-03
1/8.23
Gossen Metrawatt GmbH | Südwestpark 15 | 90449 Nürnberg Germany
Phone +49 911 8602-0 | Telefax +49 911 8602-669
info@gossenmetrawatt.com | www.gossenmetrawatt.com

2
Safety Precautions
For proper and safe use, please read and follow these instructions carefully and
completely.
The instructions must be provided to every user of the instrument.
Keep for future reference.
General
• The instrument may only be used by adequately trained specialists.
• Observe and comply with all safety regulations applicable for your work environment.
• Wear suitable and appropriate personal protective equipment (PPE) during all work.
• In particular, the relevant safety regulations in VDE 0100, 0800, and 0805 must be
adhered to.
Accessories
• Use only the specied accessories (included in delivery or listed as optional) with the instru-
ment.
• -Carefully and completely read and adhere to the product documentation for optional acces
sories. Retain these documents for future reference.
Handling
• The instrument may only be used in data and telecommunications networks that are free of
external voltages.
External voltages greater than 60 V DC can destroy the instrument and also represent a
potential health hazard to the user!
• Never pull unnecessarily on the cables connected to the instrument.
• Use the instrument in undamaged condition only.
Inspect the instrument before use. Pay particular attention to damage, broken insulation, or
kinked cables.
• Use the accessories and all cables in undamaged condition only.
Inspect all cables and accessories before use. Pay particular attention to damage, broken
insulation, or kinked cables.
• If the instrument or its accessories do not function awlessly, permanently remove the instru-
ment/accessories from operation and secure them against inadvertent use.
• If the instrument or accessories are damaged during use, such as if they are dropped,
permanently remove the instrument/accessories from operation and secure them against
inadvertent use.
• If there are any signs of interior damage to the instrument or accessories (e.g., loose parts
in the housing), permanently remove the instrument/accessories from operation and secure
them against inadvertent use.
• The instrument and accessories may only be used for the tests/measurements described in
the documentation for the instrument.
Operating Conditions
• -Do not use the instrument and its accessories after long periods of storage under unfavor
able conditions (e.g., humidity, dust, or extreme temperatures).
• Do not use the instrument and the accessories after extraordinary stressing due to transport.
• Do not expose the instrument to direct sunlight.

3
• Only use the instrument and the accessories in compliance with the specied technical data
and under the specied conditions.
• Do not use the product in potentially explosive atmospheres. Danger of explosion!
Batteries
• Use batteries in undamaged condition only. There is a risk of explosion and re if the batter-
ies are damaged!
• Inspect the batteries before use. Pay particular attention to leaky and damaged batteries.
• Only use the instrument with the battery compartment lid inserted and closed.
Measurement Cables and Establishing Contact
• Never touch conductive ends or wires.
• Make sure that good contact has been made.
Data Security
• Always create a backup copy of your measurement data.
• The instrument is equipped with a data memory to which personal and/or sensitive data
can be stored. Observe and comply with the applicable national data protection regulations.
Take appropriate measures to prevent unauthorized access to the data.
Produktspezifikationen
Marke: | Gossen Metrawatt |
Kategorie: | Messgeräte |
Modell: | KE7200 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Gossen Metrawatt KE7200 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messgeräte Gossen Metrawatt
6 September 2024
Gossen Metrawatt METRALINE VT SENSE M611K Bedienungsanleitung
6 September 2024
4 September 2024
4 September 2024
2 September 2024
1 September 2024
1 September 2024
1 September 2024
1 September 2024
1 September 2024
Bedienungsanleitung Messgeräte
- Powerfix
- Perel
- Owon
- Cablexpert
- Reely
- Oscium
- Kopp
- Vimar
- TFA
- Bresser
- X-Rite
- Camille Bauer
- SecuTech
- TDE Instruments
- Wachendorff
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024