Klein Tools CL810 Bedienungsanleitung
Klein Tools
Messung
CL810
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Klein Tools CL810 (27 Seiten) in der Kategorie Messung. Dieser Bedienungsanleitung war für 6 Personen hilfreich und wurde von 3.5 Benutzern mit durchschnittlich 3.9 Sternen bewertet
Seite 1/27

INSTRUCTION MANUAL
ENGLISH
FRANÇAIS p. 33
ESPAÑOL pg. 17
600A AC/DC Auto-Ranging
Digital Clamp Meter
True RMS
Measurement
Technology
• NON-CONTACT
VOLTAGE TESTER
• LOW IMPEDANCE
• DATA & RANGE HOLD
• AUDIBLE CONTINUITY
• DIODE TEST
• CAPACITANCE & FREQUENCY
• TRANSFLECTIVE
REVERSE-CONTRAST DISPLAY
• LIGHTED DIAL
1000V
60M
Ω
600A
CL810
2
m
IP40
-40° – 1832°F
(-40° – 1000°C)
5000573
CAT IV
600V
CAT III
1000V

2 3
GENERAL SPECIFICATIONS
Klein Tools CL810 is an automatically ranging true root mean square
(TRMS) digital clamp-meter that measures AC/DC current via the clamp,
measures AC/DC voltage, resistance, continuity, frequency, inrush,
capacitance, and tests diodes via test-leads, and temperature via a
thermocouple probe. It also features a Low Impedance (LoZ) mode for
identifying and eliminating ghost or stray voltages, transflective reverse-
contrast display, and lighted dial.
• Environment: Indoor: Do not expose to moisture, rain or snow.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: 14° to 140°F (-10° to 60°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefcient: 0.1 × (Quoted Accuracy) per °C above 28°C
or below 18°C, corrections are required when ambient working
temp is outside of Accuracy Temp range
• Auto Power-Off (APO): After 5 minutes of inactivity (unless
disabled)
• Dimensions: 9.06" × 3.47" × 1.65" (230 × 88 × 42 mm)
• Weight: 13 oz. (369 g) including batteries
• Calibration: Accurate for one year
• Standards:
IEC EN 61010-1, 61010-2-032.
Conforms to: UL STD 61010-1, 61010-2-032.
Certied to: CSA STD C22.2 #61010-1, 61010-2-032.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CAT IV 600V, CAT III 1000V, Class 2,
Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy LoZ Accuracy
AC
Voltage
(V AC)
600mV 0.1mV ±(1.8% + 8 digits)
±(2.5% + 8
digits)
6.000V 1mV
±(1.0% + 3 digits)60.00V 10mV
600.0V 100mV
1000V 1V ±(1.2% + 5 digits)
DC
Voltage
(V DC)
600mV 0.1mV
±(0.5% + 5 digits)
±(2.0% + 5
digits)
6.000V 1mV
60.00V 10mV
600.0V 100mV ±(0.8% + 3 digits)
1000V 1V ±(1.0% + 3 digits)
Input Impedance: 10MΩ Frequency Range: 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
NOTE: All AC voltage ranges are specified from 5% to 100% of range.
AC Current
(A AC)
60.00A 10mA ±(2.0% + 8 digits)
600.0A 100mA ±(2.0% + 5 digits)
DC Current
(A DC)
60.00A 10mA ±(2.0% + 8 digits)
600.0A 100mA ±(2.0% + 5 digits)
Frequency Range: 50 to 60Hz
DC
Microamps
(DC µ)
200.0µA 0.1µA ±(1.0% + 5 digits)
Maximum Input: 1000V AC RMS or 1000V DC
Function Range Resolution Accuracy
Resistance
600.0Ω 0.1Ω
±(1.2% + 5 digits)
6.000kΩ 1Ω
60.00kΩ 0.01kΩ
600.0kΩ 0.1kΩ
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 10 digits)
Maximum Input: 1000V AC RMS or 1000V DC
Capacitance
60.00nF 0.01nF ±(3.5% + 10 digits)
600.0nF 0.1nF
±(3.0% + 5 digits)
6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF
6000µF 1µF ±(3.5% + 5 digits)
Maximum Input: 1000V AC RMS or 1000V DC
Temperature
(Fahrenheit)
-40° to 10°F
1
°F
±(1.2% + 7
°F
)
11° to 1832°F
±(1.2% + 6
°F
)
Temperature
(Celsius)
-40° to -12°C
1
°C
±(1.2% + 4
°C
)
-11° to 1000°C
±(1.3% + 3
°C
)
ENGLISH
5000573
Produktspezifikationen
Marke: | Klein Tools |
Kategorie: | Messung |
Modell: | CL810 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Klein Tools CL810 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Klein Tools

30 Mai 2025

6 Juni 2024

6 Juni 2024

6 Juni 2024

29 Mai 2024

27 April 2024

25 April 2024

7 April 2024

10 März 2024
Bedienungsanleitung Messung
- Messung PeakTech
- Messung TFA Dostmann
- Messung Eurolite
- Messung Camille Bauer
- Messung Beha-Amprobe
- Messung Eltako
- Messung Carrier
- Messung AstroAI
- Messung PCE Instruments
- Messung Cliff
- Messung Danfoss
- Messung Victron Energy
- Messung VirtuFit
- Messung Meec Tools
- Messung Beckmann & Egle
Neueste Bedienungsanleitung für -Kategorien-

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025

4 Juni 2025