Klein Tools MM200 Bedienungsanleitung


Lies die bedienungsanleitung für Klein Tools MM200 (6 Seiten) kostenlos online; sie gehört zur Kategorie Multimeter. Dieses Handbuch wurde von 36 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 8 Bewertungen. Hast du eine Frage zu Klein Tools MM200 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/6
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
139572TRev. 06/10
Instruction
Manual
ENGLISH
www.kleintools.com
Instruction
Manual
MM200
For Professionals...Since 1857
®
ENGLISH
•BACKLIGHT
•KICK STAND
•LEAD
HOLDER
•AUTO
RANGING
•DATA HOLD
•3-3/4 DIGIT
3999 COUNT
LCD
CATIII
COM
m
10A/500V
~
400mA/250V
~
600V MAX
Temp
FUNC.
HOLD
MM200
H
z%
mA
A
µA
Temp
H
z%
FIleName:MKT121707-MM200-Multimeters-139572TART
Product:MM200
PackagePart#:139572T
Date:4/06/10
Designer/Production:Sandraex15612
ClientContact:ChrisTrott,ex13267
ClientSignoff:
SYMBOLS USED ON LCD
~
AC MeasurementDC Measurement
-
Negative DC Value
OL
Overload: Range Exceeded
Low Battery
H
Hold Active
AUTO
Auto Range Active
V
Voltage Measurement
%
Duty Cycle ModeFrequency Mode
A
Current in Amps
Ω
Resistance in Ohms
Diode TestContinuity Test
n
Nano 10
-9
°
F
Temperature in Fahrenheit
m
Milli 10
-3
F
Capacitance in Farads
µ
Micro 10
-6
M
Mega 10
6
k
Kilo 10
3
H
z%
mA
A
µA
Temp
H
z%
mA
A
µA
Temp
• Safely discharge capacitor before measurement.
•Reading may take up to 60 seconds for large capacitors.
7. Frequency (Hz)/Duty Cycle < 1MHz
•Use included thermocouple and adapter.
•Do not apply voltage to thermocouple.
•Follow AC Voltage test setup.
8. Temperature: -
°F
1832°
WARRANTY
This product is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. During this warranty period,
Klein Tools has the option to repair or replace or refund the purchase price of
any unit which fails to conform to this warranty under normal use and service.
This warranty does not cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse, abuse, neglect, or improper
maintenance. Batteries and damage resulting from failed batteries are not
covered by warranty. A purchase receipt or other proof of original purchase date
will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. Klein Tools shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state. If your Klein product requires
repair or for information on how to exercise your rights under the terms of this
warranty, please contact Klein Tools at 1-877-775-5346.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
Max Input Current:
•mA Input: 400mA DC / AC RMS
•10A Input: 10A DC / AC RMS
AC/DC Current Measurement
RangeResolutionDC AccuracyAC Accuracy
400μA ~ 400mA0.1μA ~ 0.1mA± (1.0% + 3 d)± (1.2% + 3 d)
10A0.01A± (3.0% + 5 d)± (3.0% + 5 d)
Overload Protection:
•mA Input: F400mA / 250V fuse
•10A Input: F10A / 500V fuse
Diode Test
Overload ProtectionTest CurrentOpen Circuit Voltage
600V RMSAppx. 0.6mAAppx. < 1.5V DC
Continuity Test
Overload ProtectionOpen Circuit Voltage
600V RMSAppx. 0.44V
H
z%
Temp
6. Capacitance < 200µF
H
z%
Hz
PRESS
%
COM
m
10A/250V
~
400mA/250V
~
600V MAX
Temp
H
z%
mA
A
µA
Temp
COM
m
10A/250V
~
400mA/250V
~
600V MAX
Temp
H
z%
mA
A
µA
Temp
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
RangeResolutionAccuracy
400mV ~ 600V0.1mV ~ 1V± (0.5% + 3 digits)
Overload Protection: 600V RMS Input Impedance: > 10MΩ.
Capacitance Measurement
RangeResolutionAccuracy
4nF ~ 40μF0.001nF ~ 0.01μF± (3.0% + 6 digits)
200μF0.1μF± (4.0% + 6 digits)
Overload Protection: 600V RMS
4nF Range: Stated accuracy with film capacitor or better.
Frequency Measurement
RangeResolutionAccuracy
9.999Hz ~ 999.9kHz0.001Hz ~ 0.1kHz± (0.5% + 2 digits)
Overload Protection: 600V RMS
Sensitivity: 0.7V RMS at 1MHz
Temperature Measurement
RangeResolutionAccuracy
-4°F ~ 32°F1°F± (5.0% + 2 digits)
32°F ~ 1832°F1°F± (3.0% + 2 digits)
Overload Protection: 600V RMS
Sensor: K-type thermocouple, accuracy not listed
Duty Cycle Measurement
RangeResolutionAccuracy
0.1% ~ 99.9%0.1%± (2% + 5 digits)
Overload Protection: 600V RMS
Frequency: 0.5Hz ~ 100kHz (pulsewidth > 2μsec)
Resistance Measurement
RangeResolutionAccuracy
400Ω ~ 4MΩ0.1Ω ~ 0.001MΩ± (0.8% + 4 digits)
40MΩ0.01MΩ± (1.5% + 4 digits)
Overload Protection: 600V RMS
AC Voltage Measurement
RangeResolutionAccuracy
4V ~ 600V1mV ~ 1V± (1.2% + 5 digits)
Overload Protection: 600V RMS Frequency: 50 ~ 60Hz
Input Impedance: > 10MΩ Response: Averaging
MM200-Instructions-139572TART.indd 1-46/3/10 8:41 AM