Lies die bedienungsanleitung für NuTone 665RP (12 Seiten) kostenlos online; sie gehört zur Kategorie Ventilator. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu NuTone 665RP oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/12
MODEL 665RP
Page 1
HEATER / FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
To register this product, visit:
www.nutone.com
IMPORTANT INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLING
OR USING THIS HEATER.
the following:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or tele-
phone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning de-
vice, such as a tag, to the service panel.
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
5. This heater is hot when in use. To avoid burns, do not let bare skin
touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, etc. and curtains at least 3 feet
(0.9 m) from the front of the heater.
6. Extreme caution is necessary when any heater is used by or near
children or invalids and whenever the heater is left operating and
unattended.
7. Do not operate any heater after it malfunctions. Disconnect power at
service panel and have heater inspected by a reputable electrician
before reusing.
8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off power to heat-
er circuit at main disconnect panel (or operate internal disconnect
switch, if provided).
10. Do not insert or allow foreign objects to enter any ventilation or ex-
haust opening, as this may cause an electric shock or fire, or dam-
age the heater.
11. To prevent a possible fire, do not block air intakes or exhaust in any
manner.
12. A heater has hot and arcing or sparking parts inside. Do not use it
in areas where gasoline, paint, or flammable vapors or liquids are
used or stored.
13. Use this heater only as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electric shock,
or injury to persons.
14. This product must be grounded.
15. Do not install heater in a tub or shower enclosure.
16. This product is designed for ceiling installation only. This product
is designed for installation in ceilings up to a12/12 pitch. Ductwork
must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
17. Install heater at least 12 inches from floor or any adjacent wall.
18. Do not connect heater to dimmer switch or speed control.
19. Provide a separate 20 AMP circuit. Use 12 GA. power cable of type
which meets code. Use supply wiring rated for at least 90
O
C.
20. For greatest efficiency, install heater so heat is directed toward tub
or shower area. Avoid directing toward walls or windows.
SAVE THESE INSTRUCTIONS
PREPARATION
1. Remove the lamp
holder assembly.
2. Remove the heater
assembly retaining
screw.
3. Rotate heater assembly
and lift it up and out of the
housing.
4. Remove fan assembly
retaining screws. Lift
fan assembly out of the
housing.
5. Slide the 4 hanger
bars into the slots
on each end of the
housing - 2 hanger
bars per side.
MODEL 665RP
Page 2
For best results, choose a
location which allows fan to
be vented outside with the
shortest possible duct run
and the fewest number of
elbows.
1. Position unit between
joists and extend mount-
ing brackets. Position
brackets such that the
bottom edge of housing will be flush with finished ceiling.
Mark the top of keyhole slot on all four mounting brackets.
INSTALLATION
2. Remove unit tem-
porarily, and pound
nails partially into
joists at all four
marked locations.
3. Hang unit from nails and
check if unit will be flush with
finished ceiling. Pound nails
tight. For wide joist centers:
A #8 x 3/8 self-tapping screw
can be used to join extended
brackets together and cre-
ate a rigid mount. To ensure
a noise-free mount, crimp
the bracket channels tightly
around mounting brackets.
WARNING: To reduce the risk of fire, do not store or use
gasoline or other flammable vapors and liquids in the vicin-
ity of the heater.
CAUTION: High temperature, risk of fire, keep electrical cords,
drapery, furnishings, and other combustibles at least 3 feet
(0.9 m) from the front of the heater and away from the side
and rear.
MODEL 665RP
Page 3
RED
BLACK
120 VAC LINE IN
HEAT
VENT
LIGHT
3 GROUND
WIRES
3 GROUND WIRES
A
B
C
LIGHT
VENT
HEAT
BLUE
3 WHITE WIRES
BLACK
RED
2 WHITE
WIRES
BLACK
3 WHITE WIRES
B
C
A
4. Use a flat-bladed
screwdriver
to remove the
proper electrical
knockouts.
5. Connect
electrical
wiring as
shown.
6. Replace the fan assembly removed in Step 4, under “PRE-
PARE THE UNIT” on Page 2. Plug fan assembly into recep-
tacle (C) on the the side of the wiring cover. Direct wires away
from blower inlets.
7. Replace the heater assembly removed in Steps 2, 3, under
“PREPARE THE UNIT” on Page 2. Plug heater assembly into
receptacle (A). Direct wires away from blower inlets.
If the switch has not been wired properly and wires need to
be moved:
1. Each wire opening has a release slot.
2. Push a small nail or screwdriver into release slot while
gently removing wire.
3. DO NOT pull any wire out of the switch without using
the release slot. The switch may be damaged.
WIRE OPENING
RELEASE SLOT
8. Install grille and
light reflector.
Plug light into
receptacle (B).
Tighten acorn
nut securely.
Be careful not
to overtighten
nut and deform
reflector.
Install a 100 Watt
(maximum) light
bulb.
9. Install light
lens. Gently
squeeze tabs
on lens and
insert them
into the slots
in the grille.
Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.