Features:
• Supplied with two probes, main rotation probe for instant readings and an external probe for constant temperature monitoring.
• Large easy to read back-lit LCD display.
• Temperature alarm.
• IP65 waterproof rating (when charge input and external probe rubber cover is installed correctly)
• Fahrenheit or Celsius temperature measurement.
• Measurement accuracy: ±1°C (±2°F) at -20°C-150°C (-4°F-302°F)
• Internal magnet for easy mounting.
• Display temperature hold function.
• Internal rechargeable battery, USB-C cable supplied, to be used with Type A-USB output connection with a minimum of 5V 1.5A output.
• Auto Shut-off after 10 mins of inactivity if the measured temperature is below 50°C and the temperature change is within 3°C/6°F
Operation:
1. Before using the thermometer, please peel-off the protective lm from the front panel.
2. The unit comes with two probes, one is a built-in rotation probe, the other is an external wired probe.
1To use the built-in rotation probe, rotate the probe away from its body, the thermometer will automatically turn on. To turn off, rotate the probe
back in to its original position.
2To use the external probe, release the rubber cover and insert the probe into the round jack connection, the display will turn on and show “OUT”
below the battery indicator, to turn off remove the probe and reinstall the rubber cover. (Note: when the external probe is connected the thermometer
will only read the temperature from the external probe) NOTE: Thermometer is not waterproof when using external probe.
3. The default temperature measurement is in Celsius. To change to Fahrenheit, please hold down the
button for 2s
4. Data-hold: to hold a temp reading press the
RESET
button. This will hold the temperature reading, press again to remove the hold.
5. Long-press the
RESET
button for 3s to reset the device to factory default settings.
6. To turn on the backlight, press the
button once, press it again to turn off. The backlight will turn off automatically after 10s of inactivity.
7. To set the temperature alarm, press the
button once, the set temperature value will start to ash, press the button to increase the
number or press the
RESET
button to decrease the number.
To save the selected temperature, press the
button. If the temperature rises above the set temperature, the thermometer will beep and
ash “alarm set”. The alarm will turn off automatically after one minute, the “alarm set” will keep ashing until the temperature falls below the set
temperature or if the thermometer is turned off. You can also stop the alarm by pressing any button.
8. How To Recharge: When the power is low, the battery icon on the display will ash, plug in the supplied USB cable as per images below then plug
the cable into a power adaptor (5V 1.5A, not supplied) to charge.
Warnings and Product Safety
1. Always wear a heat resistant glove when touching the stainless steel probe sensor or wire during or just after cooking. Do not touch with bare hands.
2. Keep the stainless steel probe sensor and wire away from children.
3. Clean the stainless steel probes and dry thoroughly after each and every use. Wash the metal probe tips with hot soapy water and dry thoroughly.
Wipe the unit with a damp cloth. Do not immerse unit in water while cleaning.
4. Do not use the unit in the rain.
5. Do not expose the plugs of the stainless steel probes or the jack holes of the unit to water or any liquid. This will result in a bad connection and/
or faulty readings.
6. Do not expose the unit to direct heat or hot surfaces. Do not use stainless steel probes in microwave ovens.
7. Do not use the stainless probe sensor above 300°C (572°F). Doing so may damage the probe.
8. Do not expose the external probe wire to temperatures above 380°C (716°F). This will damage the wire.
9. Do not drop the unit or subject it to sudden shock or impact. Do not disassemble the unit.