Lies die bedienungsanleitung für Pentatech RA170Q (2 Seiten) kostenlos online; sie gehört zur Kategorie Rauchmelder. Dieses Handbuch wurde von 33 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 6 Bewertungen. Hast du eine Frage zu Pentatech RA170Q oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

Where to locate
Installation
Forminimum protection, smoke alarms should be installed in
every bedroom, children'sroom andhallway. Inhabitable
attics, a smokealarm should beinstalled abovethe stairs.
The alarmsound mustbeloud enough towakesleeping
residentsin the case of fire.
In the case of open connections between floors,one smoke
alarm should beinstalled on each level.
Smoke alarmsmust be installedontheceiling,asclose tothe
center ofthe ceilingaspossible. Theminimum distanceto
walls,lightfittings,electrical wiringsandapplilances,beams,
and furniture must be 50cm.
In rooms where the ceilinghas a slope of > 20°,"dead"airat
the peakof the ceilingmay prevent the smoke fromrising.
Therefore inthese rooms,the smokealarmsmustbeinstalled
min. 0.5 mandmax. 1 m fromthe peak of the ceiling. Ceilings
withan inclination of20°should be regardedas horizontal
ceilings.
In L-shaped rooms, thesmokealarm should beinstalled at the
mitreline(see diagram).Inlarge L-shapedrooms,eachside
of the room should be regarded as a separate room.
The maximuminstallationheight of asmoke alarm shouldnot
exceed 6m.
Rooms that are separated bypartition walls, beams, or
furniture,should be protected by a smoke alarm in each part of
theroom.
Ifthe roomislargerthan60m²,theinstallationofadditional
smokealarmsisnecessary.
Inhallwayswith amaximumbreadthof3m, thedistance
between twosmoke alarmsmust notexceed15m.The
distance ofasmoke alarm tothe end wallmustnot exceed
7.5m. Ineachintersection, junction,andcornerofahallway,
theremustbeonesmokealarm(mitreline).
The smokealarm shouldbe easilyaccessible to carryout
cleaning and testing.
Further information about thelocation of smokealarms can be found in theDIN 14676.
If a building is too complicated or too large,please contact a security expert or the firedepartment.
On thewallor near doors,windows, openings in theceiling,fansetc., where draftsmayblowaway smoke
or cause false alarms.
In areas where thetemperatures are regularly below 0°Cor above 55°C.
In high humidity areas (e.g.bathroom).
In small or poorly ventilated garagesor kitchens,whereexhaust fumesor steam may cause false alarms.
In insect-infected areas.
In placeswhere youcannot easily access the smoke alarm for testing and cleaning.
In areaswhere aircirculationmaycause false alarms, e.g.in staircases outside theapartments (in
apartmenthouses).
Near light fittings or electrical wiring and appliances.
Near extremely bright light sources or direct sunlight.
In areaswhere dustordirtmayimpairthe functionof thesmoke alarmorcause falsealarms (e.g.
workshops or barns).
In areas where heavy cigarettesmoke can be expected.
Near openfireplaces,ovens,stoves etc.(minimum distance 4m).
<
Locations toAvoid:
(minimumdistance50cm)
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Userand InstallationManual
Properuse
Technicaldata
Package contents
Safety instructions
Please readthis manual completely -it contains importantinformation on thefunction, installation,
placementand maintenanceofthis product.Pleasekeep thismanualand handitout tothirdpersons,if
necessary. Ifthis unitisinstalledby aninstaller, thismanual mustbe handedout tothe ownerofthe
apartment after installation.Owners or residents are responsiblefor maintaining thesmoke alarm.
Installation site:Date of initial operation:
This smoke alarm detects smokefrom smoldering fires at an early stage andwarns with a loud pulsating alarm
(85dBA/3m).Itisdesigned forthe usein privatehouseholdsandhabitable recreationalvehiclesandisnot
approved forpublic,industrial orcommercial buildings.Thefieldsofoperation ofsmokealarms are described
inDIN 14676.Inthecase offire, smoke alarmscan onlygive alarm,ifthesmoke reachesthem. Everything
that preventsthesmoke fromentering the smokealarm'shousing may delayor even preventthealarm.A fire
in another room,floor, or areaof the homewillonly be reportedwhenthesmoke reachesthesmoke alarm. For
this reason, youshould installa smokealarm in everyroom -at leastone oneach floor,observe theminimum
protection accordingtoyourlocallegislation.Smokealarmsarenosubstitute fora property orlife insurance.
Appropriate coverageis your responsibility. This smoke alarm is not suitable for deaf persons.
Contaminationof the smokealarm bydust ordirt may leadto falsealarms. Ifthedirtcannot beremovedfrom
outside as described inthe chapter "Maintenance/Cleaning", theunit has to be replacedby a newone. There is
no warrantyfor dirtyunits. Thissmoke alarmisequipped witha built-innon-exchangeablebatteryand hasto
bereplacedafter 10yearsof operationatthe latest.Areliableearlywarning offireand smokeisonly given,if
this smokealarm is used according to theseinstructions.
Unlessthere is a statutory obligation, the manufacturer is not responsiblefor further claims, includingpersonal
or material damages, arising from theuseof the product or from nonfunction or malfunction of the product.
Operating voltage:3 VDC
Power supply:1pc. 3 Vbuilt-in lithiumbattery
Battery lifetime:10 years*
Battery warning:up to 30 days, one beep approx. every 40 seconds
Smokesensor: photoelectric
Warning sound:piezo-electric, 85dB(A) at 3 m
Operation indication:status indicatorflashesweakly approx. every 40 seconds
Alarm silencing indication:status indicatorflashesweakly approx. every 5 seconds
Test button:to test electronics, battery and warning sound
Temperaturerange:0° to+55°C
Air humidity:20% to80 %
Tests:accordingto DIN EN14604and vfdb 14-01,produced in
certified production site according to ISO 9001
* calculated life expectancy in normal use, at 21° C,without alarm triggering
Smoke alarm with built-in battery and mounting plate
3M adhesive pad
Do notdamageany gas,electricity, wateror telecommunication linesduring drilling andfixing work.
Otherwise there aredangers of fire, personal and fatalinjury.
Ensure thatthe alarmsirenis not activated next to somebody'sear. Otherwise there isadangerofhearing
damage!
Do notpaint or pastethe smokealarm, and donot cover it, otherwiseitsfunction will be impaired.
Avoidtouching leaking ordamagedbatteries!Use suitable safetyglovesandclothing! Otherwise you may
riskinjurybycausticacid!
Do not short-out batteries, and do not rechargethem. Otherwiseyou may risk death by explosion!
Do not ty to openthem, and do not burn them!Otherwise there is danger of explosion!
"
!
!
!
!
!
!
!
!
RA170Q
SMOKE ALARM
WITH 10 YEARLONG LIFE BATTERY
Indexa GmbH
Paul-Böhringer-Str. 3
D-74229 Oedheim
Germany
Subject to change, 2024/03/18
Extended testaccording
to vfdb 14-01
24
1116
Declaration of Performance: RA170Q-DoP-001
1116-CPR-181-3
EN 14604:2005+AC:2008
Purpose: fire protection (smoke detector)
SMOKE ALARMRA170Q
Declaration ofPerformance according to CPR
available at www.indexa.de
1.
2.
Mounting plate
Holes for screws
3. Brackets
4. Openings
5. Button
6.Status indicator
123 324456
!
!
2 x screws and2 x plugs
User andinstallation manual
Example: large hallway
Example: L-shaped room
Example: apartment
Example: multi-storey home
smokealarm: minimum protection
smoke alarm: increased protection
bedroom bathroomkitchen
bedroom bedroom
living
room
attic
bedroom bedroom
living roomdining room
basement basement
1/2 1/2
1/21/2
max. 15 m
max. 7.5 m
Produktspezifikationen
| Marke: | Pentatech |
| Kategorie: | Rauchmelder |
| Modell: | RA170Q |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Pentatech RA170Q benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Rauchmelder Pentatech
25 November 2024
25 November 2024
25 November 2024
24 November 2024
24 November 2024
24 November 2024
19 August 2024
Bedienungsanleitung Rauchmelder
Neueste Bedienungsanleitung für -Kategorien-
12 Januar 2026
10 Januar 2026
6 Januar 2026
30 Dezember 2026
29 Dezember 2026
10 Dezember 2025
9 Dezember 2025
8 Dezember 2025
12 November 2025
5 November 2025