Rane MA 6 Bedienungsanleitung

Rane Mischer MA 6

Lies die bedienungsanleitung für Rane MA 6 (10 Seiten) kostenlos online; sie gehört zur Kategorie Mischer. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.4 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Rane MA 6 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/10
MA 6
OPERATING
A N D
SERVICE
MANUAL
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
serviceable parts inside. Refer servicing to qualied service personnel.
e symbols shown below are internationally accepted symbols that warn
of potential hazards with electrical products.
is symbol indicates that a dangerous voltage
constituting a risk of electric shock is present within
this unit.
is symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
WARNING
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with manufacturers instructions.
8. Do not install near any heat sources such as radiators, registers, stoves, or other apparatus (including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A ground-
ing-type plug has two blades and a third grounding prong. e wide blade or third prong is provided for your safety. If the provided plug does not
t into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord and plug from being walked on or pinched particularly at plugs, convenience receptacles, and the point where it exits from
the apparatus.
11. Only use attachments and accessories specied by Rane.
12. Use only with the cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply
cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
15. e plug on the power cord is the AC mains disconnect device and must remain readily operable. To completely disconnect this apparatus from
the AC mains, disconnect the power supply cord plug from the AC receptacle.
16. is apparatus shall be connected to a mains socket outlet with a protective earthing connection.
17. When permanently connected, an all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electri-
cal installation of the building.
18. If rackmounting, provide adequate ventilation. Equipment may be located above or below this apparatus, but some equipment (like large power
ampliers) may cause an unacceptable amount of hum or may generate too much heat and degrade the performance of this apparatus.
19. is apparatus may be installed in an industry standard equipment rack. Use screws through all mounting holes to provide the best support.
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture. Apparatus shall not be exposed to dripping
or splashing and no objects lled with liquids, such as vases, shall be placed on the apparatus.
NOTE: is equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. ese
limits are designed to provide reasonable protection against harmful interference in a residential installation. is equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
CAUT ION: Changes or modications not expressly approved by Rane Corporation could void the user's authority to operate the equipment.
is Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
PANEL DESCRIPTIONS
Front Panel
1. POWER SWITCH: Obediently turns the MA 6 on and off every time you poke it with your
finger (or other suitable object). All six channels have delayed turn-on/ instant turn-off relays to
eliminate any switching transients.
2. THERMALOVERLOAD INDICATOR: This red LED will light up if the MA 6 becomes too
hot, indicatingthat power has been removed from all six channels, while the fan continues to
cool the heatsink assembly. Be sure to check the fan filter and actual speaker impedances if
this indicator lights up.
3. POWER INDICATOR: This yellow LED lights whenever the MA 6 power switch is turned
on.
4. SIGNAL PRESENT INDICATORS: Each of these green LEDs will light whenever the input
to the channel is -20 dBm or greater. These LEDs will assist you in identifying which channels
carry which-signal,. as well as being handy troubleshooting aids in the event of signal loss.
5. LIMIT INDICATORS: Each of these yellow LEDs will light whenever that particular
channel enters the limit mode. This means that the amplifier has turned down the input level
quickly and automaticallyto avoid clipping. See elsewhere for further explanation of the MA
6 limiters and how best to use them.
6. CLIP INDICATORS: Each of these red LEDs will light whenever that particular channel
reaches -3 dB before actual clipping.