Lies die bedienungsanleitung für Valcom V-9927A (4 Seiten) kostenlos online; sie gehört zur Kategorie Alarmton. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 3.8 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Valcom V-9927A oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

VSP-9927A
V-9927A
DIGITAL MULTI-TONE GENERATOR
SPECIFICATIONS
Power Requirements:
-24VDC “B” Battery at 100mA
Operating Environment:
Temperature: 0 to +50° C
Humidity: 0 to 85% (non-condensing)
Nominal Input/Output Specifications:
Input Impedance: 600 Ohms
Output Impedance: Less than 4 Ohms
Min. Output Load Impedance: 20 Ohms
Audio Input: 0dBm nominal
Maximum Tone Output: > 0dBm single tone
Physical Dimensions:
8.20”H X 4.55”W X 2.30”D
(20.83cm H x 11.56cm W x 5.84cm D)
Weight: 1.5 lbs (0.68 kg)
INTRODUCTION
The V-9927A was designed with ease of installation
and flexibility in mind. Connections are by screw
terminals located on the edge of the PCB. The
various options and tones are set using option blocks
located inside the enclosure on the PC Board.
The V-9927A is a microprocessor controlled multi-
tone generator capable of producing a variety of tone
signals for various applications. It is functional and
backward compatible with the previous V-9927.
Note: Double check all wiring as connections to
the unit are different.
This equipment has been tested and found to
comply with the limits for a Class A digital device
pursuant to Part 15 of FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference when this equipment is operated
in a commercial environment. This equipment
generates, uses and can radiate radio frequency
energy and if not installed and used in accordance
with the instruction manual, may cause harmful
interference to radio communications. Operation of
this equipment in a residential area is likely to cause
harmful interference in which case the user will be
required to correct the interference at his/her own
expense.
INSTALLATION
Product is intended for wall mounting only. When
mounting, open enclosure and remove circuit board.
Screw back of enclosure to backboard near the
telephone system common equipment. Snap circuit
board back in place. Both mounting holes must
be utilized to insure secure mounting of the unit.
Make connections and set tones, using option
blocks, as required for the specific application.
Refer to Tone Table on page 2 for tone descriptions.
Replace cover and plug in power supply.
OPERATION
All Tones (Except Code Call)
Operation of the V-9927A is accomplished by
applying a connection between the COM (Common)
terminal on the terminal block and the desired tone
number (1-8).
The Tone selected by terminal number 1 has priority
over others. If multiple tone inputs are being used, it
is possible to sequence tones by closing the appro-
priate contacts in the desired sequence. However,
Tone number 1 will always be placed first on the list
when it has been activated.
If multiple tones are selected at the same time, the
LOWEST tone number will have priority. If the
lowest contact is open, then the next lowest tone
number will be activated.
When a Tone is activated the INPUT source will be
faded out in 0.75 seconds if P5 is out or will be faded
out in 0.25 seconds if P5 is IN.
The V-9927A has a buffer for 32 tones. If more than
32 tones are entered within a short period, the
V-9927A will drop the last tone entered.
Figure 2 illustrates several of the ways the V-9927A
can be used with other Valcom equipment.
Issue 4
1 947926

Code Call Operation
When the V V-9927A is connected to the -9923A code
call unit, the V-9927A will respond to the contact
closure inputs and issue single chimes in response
(see Figure 2).
At the beginning of a Code Call sequence, the
INPUT source will be faded down about 6dB. It will
remain at this level until the CODE CALL sequence
has completed (including the interdigit time). At that
time, the INPUT source will be faded back up to
normal level.
When using the CODE CALL option with other tone
options, the CODE CALL may be interrupted to place
other tones in the sequence (including Tone number
1 with higher priority). However, the CODE CALL
may be out of sequence for the period that this
occurs.
TONE TABLE
CONNECTION
ON
OPTION
BLOCK DESCRIPTION
JP1 P3
COM - TONE 1
COM - TONE 2
COM - TONE 3
COM - TONE 4
COM - TONE 5
COM - TONE 6
COM - TONE 7
COM - TONE 8
IN
IN
IN
IN
IN
IN
IN
IN
* WHOOP, 698Hz, 3.9 seconds (approx.) 2 cycle minimum
* DUAL CHIME, 880Hz/698Hz
* BURST, 880Hz, 1/2 second on, 2 seconds minimum
* STEADY, 880Hz, 3 seconds minimum
TeleBell 986/784Hz, 11 per second, 10 minimum
Chimes, 986, 784, 659, 523Hz order
Chimes, 880, 698, 587, 494Hz order
CODE CALL CHIME, 784Hz (V-9923A standard)
COM - TONE 1
COM - TONE 2
COM - TONE 3
COM - TONE 4
COM - TONE 5
COM - TONE 6
COM - TONE 7
COM - TONE 8
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
> SIREN, 659Hz, center 1 cycle (approx.) 0.3Hz
> WHOOP (yelp) 659Hz, 2.5Hz, 4 minimum
> WARBLE, 494/986Hz, 6Hz rate
> STEADY 698Hz, 1 second minimum
> BURST (pulse), 494Hz, 4.5Hz rate
Chimes 659/784Hz
Chimes 986/784Hz
CODE CALL CHIME, 784Hz (V-9923A Standard)
NOTE: * denotes V-9927 compatible tones
> denotes “USA Standard Immediate Evacuation signal for industrial areas”
2

P2
P3
OUT
IN
BURST
CONT
P4
P1
UNMUTE
MUTE
P5
TONE
LVL
POWER
ON
JP1
1
2
3
4
5
6
7
8
COM
SIGNAL
IN
COM
SIGNAL
OUT
GND
-24V
TONES
Connect COM to
Desired Tone
Relay
Contact
Signal In
(Optional)
Power Supply
-24VDC
(-)
(+)
Signal
Out
Option Blocks (Jumpers shown in factory default setting))
T2
T1
Adjust for
Desired
Output Level
Green LED
on when power
is present
FIGURE 1
OUT
IN
TONE BANK
SELECT
P6
Description of Jumpers
P1 (BURST/CONT) - Sets the mode of the V-9927A. The BURST function allows one (1) tone (or sequence)
for each closure of the TONES input. The CONT function is continuous; the tone (or sequence) will
repeat while the closure on the TONES input (1-8) remains activated.
P2 & P6 - Not used on this version.
P3 (TONE BANK Select; OUT/IN) - Activates tones. Refer to the Tone Table (page 2) to determine jumper
placement for the desired tones.
P4 (UNMUTE/MUTE) - Determines if SIGNAL IN is muted or unmuted. With UNMUTE selected, the signal
returns after completion of a designated tone (or sequence) even if the relay on the TONES input (1-8)
remains connected. With MUTE selected, the signal remains off after completion of tones even if the relay
on the TONES input (1-8) is connected.
P5 (OUT/IN) -
Determines the fadeout duration of the Input Source. The INPUT source will be faded out in 0.7
seconds if P5 is OUT or will be faded out in 0.25 seconds if P5 is IN.
Compatibility with the V-9927
Set P3 to "IN" position
Set P1 for BURST or CONT as required
Set P4 to UNMUTE
Set P5 to "IN"
TONE inputs 1-4 correspond to WHOOP,
CHIME, BURST, and STEADY.
CODE CALL is available on TONE input 8.
3
Produktspezifikationen
Marke: | Valcom |
Kategorie: | Alarmton |
Modell: | V-9927A |
Produktfarbe: | Grau |
Zertifizierung: | FCC, CE |
Gehäusematerial: | Kunststoff |
Eingangsspannung: | 24 V |
Warnung Dezibel: | 0 dB |
Reihe von Modulen: | 1 |
Anzahl der Eingänge: | 1 Eingänge |
Stromverbrauch (max): | 2.4 VA |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Valcom V-9927A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Alarmton Valcom
30 Juni 2025
29 Juni 2025
Bedienungsanleitung Alarmton
- Techno Line
- Honeywell
- Homematic IP
- Geemarc
- Abus
- Oregon Scientific
- Sempre
- Irox
- Monacor
- König
- Pentatech
- Amplicomms
- La Crosse Technology
- Hama
- Cresta
Neueste Bedienungsanleitung für -Kategorien-
24 November 2024
11 Juni 2024
11 Juni 2024
27 Mai 2024
7 Mai 2024
5 Mai 2024
26 April 2024
15 April 2024
5 April 2024