Valcom V-9936A Bedienungsanleitung

Valcom Alarmton V-9936A

Lies die bedienungsanleitung für Valcom V-9936A (9 Seiten) kostenlos online; sie gehört zur Kategorie Alarmton. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.4 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Valcom V-9936A oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/9
VSP V- -9936A
Issue 5
1 947961
V-9936A
SIX LINE C. O. AUDIBLE RING UNIT
INTRODUCTION
The V-9936A is a Six Line C. O. Audible Ring Unit to
be used with Electronic key and PABX telephone
These instructions contain the specifications and
information necessary to install, operate and maintain
the Six Line C. O. Audible Ring Unit.
When installing the V-9936A, notify the local
telephone company with the following information:
The telephone number of the lines to which the
V-9936A will be connected
The FCC Registration number of the V-9936A,
which is BAF9I7- -12995 RG-N
The ringer equivalence number (REN): 0.7B
SPECIFICATIONS
Purpose
Monitors up to six C. O. Lines or PABX station
numbers and gives a common audible tone signal
and a dry relay contact closure to indicate
incoming ring on any of the lines.
V-9936A units may be multiplied to supervise
additional lines.
Applications
Central office lines
PABX station numbers
Phone system night ring relay
Features
Monitors six lines
Units may be multiplied for additional lines
Provides interrupted electronic warble tone
output for tone signaling
Provides interrupted dry contact closure output
to activate loud bells
Input for a night switch (On/Off switch)
Built-in 66 type connection block
May be connected to an existing paging system
Drives up to 150 Valcom One-way Amplified
Speaker Assemblies
Drives up to two 45 Ohm Talkback Speakers
May be used with One-way or Talkback Paging
Systems
May be used with 70 Volt Paging Systems
Ring tone will override any page in progress
Volume control
Power reversal indicator
Powered by -24VDC "B" battery
Capacity
Each V-9936A will provide signaling for six C.O.
lines or extension numbers
Up to four units may be multiplied for monitoring
of 24 lines
May be connected to one zone of a paging
system
The V-9936A will drive two 45 Ohm talkback
speakers or 150 one-way amplified speaker
assemblies
The dry contact closure is rated at 1.0 Amp @
105VAC, or 2.0 Amps @ 24VDC.
2
Dimensions/Weight
8.20" H x 4.55" W x 2.30" D
(20.83cm H x 11.56cm W x 5.84cm D)
1.5 lbs. (.68 kg)
Power Requirements
-21.5 to -26VDC "B" Battery, 200mA maximum
Environment
Temperature: 0 to +50 Degrees C
Humidity: 0 to 85% non-precipitating
DESIGN
General
The Valcom V-9936A is designed to monitor up to six
C. O. lines or PABX station numbers and will provide
a common tone signal and contact closure whenever
any of the lines are ringing. The V-9936A may be
used with most telephone systems because it
connects directly to the lines and not to the phones.
The tone output may be connected to speakers used
only for ringing or to one zone of a paging system.
The dry contact closure may be used to activate loud
ringing bells, strobes or other external equipment.
Both outputs will provide interrupted signals
whenever any line is ringing.
A disable input is provided for connection of a night
switch. With no switch connected, the V-9936A will
signal any time a line rings in. With a switch
connected and providing a short across the disable
input, the unit will be inactive.
Stand-Alone Ringing
The following components are required to provide
common audible ringing over dedicated bells or
speakers.
V-9936A C. O. Ring Units, 1 per 6 lines
Signaling Devices consisting of:
a. Two 45 Ohm talkback speakers or
b. Up to 150 one-way amplified speakers or
c. Loud bells, buzzers, strobes etc. as required
Power Supply: The VP-624B will power a V-9936A
using talkback speakers for signaling. If one-way
speaker assemblies or other signaling devices are
used, additional power may be required.
Ringing Over Paging
Ringing may be connected to one zone of a Valcom
One-way or Talkback Paging System or to the INPUT
of a high powered amplifier. The following
components are required:
V-9936A C. O. Ring Units, 1 per 6 lines
VP- - -624B 24VDC Power Supply (VP 4024C if
using more than (3) V-9936A's).
If a page is in progress when an incoming call is
detected, the ring signal from the V-9936A will
momentarily override the page.
FIGURE 1 - TYPICAL INSTALLATION
INSTALLATION
The following sections contain step- -by step
instructions for wiring the V-9936A and associated
Valcom equipment. Each instruction is preceded by a
line; place a check on the appropriate line as the
instruction is completed. The instructions also
include tests along the way to verify connections
have been made correctly. If these steps are followed
exactly, installation should go smoothly and quickly.
If the results of a test do not correspond with what is
shown, DO NOT PROCEED UNTIL THE PROBLEM
HAS BEEN CORRECTED.
Set individual volume controls at approximately 1/2
volume for testing when installing the control unit
and any one-way amplified speaker assemblies.
Mounting
Remove the metal mounting plate from the rear of the
V-9936A enclosure. Using two #6 x 3/4" wood
screws, mount the plate in a vacant space on the
backboard with the telephone system common
equipment. Both mounting holes must be utilized to
insure secure mounting of the unit. See Figure A.
Open the V-9936A enclosure to access connections
and option switches. Slide the rear of the unit
(Contains the board) onto the mounting plate and
lock in place with screw provided. Make connections
and replace cover after all connections are
accomplished. Lock cover in place using the #6 x 1/2"
screw provided.
C.O.1
C.O.2
C.O.6
TELEPHONE
SYSTEM
PA GE
OUT
V-9936A
WARBLE
TONE
GENERATOR
(Page Control Unit
may not be required)
3
TO REMOVE COVER
LOOSEN SCREW,
THEN ACTIVATE LATCH
PLASTIC
COVER
CIRCUIT BOARD
HOUSING ASSEMBLY
METAL WALL
MOUNTING
PLATE
WIREWAY OPENING
TO WALL PLATE AND
JUNCTION BOX
WIRE TIE LOOP
WIRE TIE USED TO BUNDLE WIRES
ENTERING AND LEAVING TERMINAL AREA
SNAP LATCH
FOR COVER
.155 DIA. HOLES FOR MOUNTING TO
SINGLE OR DOUBLE GANG JUNCTION BOX
HOLE PATTERN MATCHES BOTH EURO
AND US JUNCTION BOXES
1.5 x 2 WIRE ACCESS OPENING
TO JUNCTION BOX
BRACKET
LOCKING
SCREW
FIGURE A


Produktspezifikationen

Marke: Valcom
Kategorie: Alarmton
Modell: V-9936A
Produktfarbe: Grau
Zertifizierung: FCC, CE
Gehäusematerial: Kunststoff
Eingangsspannung: 24 V
Reihe von Modulen: 1
Anzahl der Eingänge: 6 Eingänge

Brauchst du Hilfe?

Wenn Sie Hilfe mit Valcom V-9936A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten