Vemer Athena.Temp Bedienungsanleitung
Vemer
Nicht kategorisiert
Athena.Temp
Lies die bedienungsanleitung für Vemer Athena.Temp (1 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 115 Personen als hilfreich bewertet und erhielt im Schnitt 3.8 Sterne aus 58 Bewertungen. Hast du eine Frage zu Vemer Athena.Temp oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/1

V3IS00371-011
Mod. Athena.temp
User Manual
ATHENA.TEMP remote probe
Read all instructions carefully
The Athena.temp device is a remote probe to measure room temperature and is designed to be
connected to the programmable thermostat.Athena
SAFETY INSTRUCTIONS
During product installation and operation, it is necessary to observe the following
instructions:
1) The device must be installed by a qualifi ed person
2) Disconnect power supply while installing the unit
3) Do not power or connect the product if any part of it is damaged
4) Connect the product considering the diagrams described in the following manual and on
the instrument
Code Model Description
VN942900 ATHENA.TEMP Remote probe
TECHNICAL SPECIFICATIONS
• Power supply: 2x1,5V (AAA) alkaline batteries
• Battery Autonomy: 12 months approx.
• Battery level control with “dead battery” sign
• Serial port for network connection (RS-485)Athena
• Measured temperature resolution: 0,1°C
• Accuracy: ±0,5°C
• Measured temperature range: 0°C ÷ 40°C
• Offset adjustment range: ±3°C
• Operating Temperature: 0°C ÷ 50°C
• Storage Temperature: -10°C ÷ 65°C
• Wall-mounting installation
• Protection degree: IP40
OPERATION
SWITCH-ON RESET AND BATTERY REPLACEMENT
• On placing the batteries (or after reset) the signalling LED will give out 2 half-second long
fl ashes (switch-on sequence).
• When the batteries on the remote probe are low, the signalling LED will give out 2 quick
fl ashes every 2 seconds. The “low battery” signal is also transmitted to the
Athena
device
(cfr.
Athena
instructions for further details on readings and signals). Low batteries must
absolutely be replaced, because communication is not reliable in this condition.
• As soon as new batteries are placed, the remote probe will resume operation by running
the switch-on sequence. If not, press the reset button.
Warning: incorrect battery positioning may damage the device and run down
the batteries.
CONFIGURATION
• Communication with the Athena programmable thermostat via bus (RS-485) can only
take place after probe confi guration.
Probe confi guration
- With the device ON (the switch-on sequence must have completed), hold down the
programming key for at least 3 seconds.
- The signalling LED will start to fl ash and will keep on fl ashing until the probe receives
a confi guration string (for string transmission method, cfr.
Athena
instructions).
- On receiving the string, the probe will be successfully confi gured: the signalling LED
will go off and the probe will resume normal operation.
- In case of various
Athena.temp
probes on the same network, repeat the confi guration
procedure for each individual probe.
OPERATION AND TEMPERATURE CONTROL
• During normal operation, the probe transmits the temperature value and the rotary
selector position whenever there is a data request from the device the probe was Athena
confi gured with. When data are transmitted the signalling LED fl ashes briefl y.
• Position the rotary selector as desired: to control the temperature according to the
setpoint selected on , rotate the selector until the reading 0 appears in the slot. In Athena
all other cases temperature control is determined by a setpoint modifi ed following a value
that matches the selected value. For instance: if the setpoint on is +20.0° C and Athena
Athena.temp's selector is in position +1.0 °C, the modifi ed setpoint value determining
temperature control will be +21.0 °C.
REFERENCE STANDARDS
Conformity to the EU directives is declared with reference to the following harmonised
standards:
Safety:
EN 60730-2-9
Electromagnetic compatibility:
EN 61000-6-1, EN 61000-6-3
Dimensions
Wiring diagram Installation
Description
Control of 4 zones by the programmable thermostatAthena
- Living Probe: built into programmable thermostatroom/kitchen Athena
- Probe: remote, connection to via bus 485 Bedroom Athena
- probe: remote, connection to via bus 485Bathroom Athena
- probe: remote, connection to via bus 485Entrance Athena
The air-conditioning equipment is controlled by programmable thermostat by Athena
means of a remote actuator via RF and/or 485 bus.(RX4-8A)
Network example
Athena.temp
Actuator
Boiler
ATHENA
+Tx.Athena
Bedroom
Bathroom
Living room
KitchenEntrance
Athena.temp
Athena.temp
RF
BUS
1 – Setpoint rotary
selector 2 – Setpoint scale
3 - Signalling led
4 – Reset button
5 – Programming button
6 – Battery
compartment
Press
Pull
Produktspezifikationen
Marke: | Vemer |
Kategorie: | Nicht kategorisiert |
Modell: | Athena.Temp |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Vemer Athena.Temp benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Vemer
2 Oktober 2024
22 September 2024
22 September 2024
18 September 2024
13 September 2024
4 September 2024
2 September 2024
26 August 2024
15 August 2024
14 August 2024
Bedienungsanleitung Nicht kategorisiert
- LawnMaster
- Peerless
- Busch-Jaeger
- Leaptel
- Geneva
- Kincrome
- Gamdias
- Matrox
- IFi Audio
- Avantone Pro
- Audio Pro
- Bxterra
- Bomann
- Hifonics
- Enovate
Neueste Bedienungsanleitung für -Kategorien-
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025