Lies die bedienungsanleitung für Cres Cor KCUA11 (9 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 2 Bewertungen. Hast du eine Frage zu Cres Cor KCUA11 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/9

5925 Heisley Road • Mentor, OH 44060-1833
KoldCube
3
Refrigerated Cabinet
FL-2379
Rev. 1 (7/19)
Page 1 of 9
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Cabinet model number:
Cabinet serial number:
Authorized Service Agency:
Ph: Fax:
Keep this manual for future reference.
KC-UA-11
KC-UA-11H
OPERATING and MAINTENANCE INSTRUCTIONS
for Cres Cor Refrigerated Cabinet, Models KCUA11 & KCUA11H

5925 Heisley Road • Mentor, OH 44060-1833
KoldCube
3
Refrigerated Cabinet
FL-2379
Rev. 1 (7/19)
Page 2 of 9
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
INITIAL SETUP:
1. Remove all packing material from inside the
cabinet
2. Clean and sanitize the interior of the cabinet. See
Cleaning Instructions on page 4.
3. Install all shelf angles on posts
4. Ensure condensate pan is secured in the back
pocket of the unit with supplied screw, and make
sure drain tube is situated so it will drain into it.
5. Plug “power supply battery charger” into wall
receptacle.
6. Plug in 12V connector into back of KoldCube,
making sure red connects to red and black
connects to black. Either inlet connector can be
used.
7. Move the switch on the power supply battery
charger to ON (I). The light on the charger will
eventually turn red, signifying the battery is
charging.
WARNING: USE ONLY SUPPLIED
BATTERY CHARGER OR CONNECT TO
12VDC SYSTEM NOT EXCEEDING 14.4VDC.
REPLACE CHARGER WITH ONLY GENUINE
CRES COR PART. USING A DIFFERENT
BATTERY CHARGER VOIDS WARRANTY
AND COULD DAMAGE EQUIPMENT OR
CREATE A POTENTIALLY HAZARDOUS
SITUATION.
FIRST TIME OPERATION:
1. Keep unit plugged into wall receptacle, charging.
2. If charger has been plugged in for over 4 hours
(with unit powered OFF) and battery monitor does
not read 100%, it has become un-sync’d. Hold the
+ and – buttons together for 3 seconds to re-sync
to 100%.
3. Press power switch ON. Switch will illuminate and
thermometer will turn on.
4. Thermometer displays internal cabinet
temperature.
5. Pre-cool the cabinet for at least 1 hour before
loading food.
NOTE: DO NOT PUT HOT FOOD INTO
COLD CABINET. UNIT IS INTENDED FOR
COLD FOOD ONLY TO BE PLACED INTO
REFRIGERATED ZONE.
NORMAL OPERATION:
1. Thermometer will always display the temperature
representing the warmest zone of the cabinet.
2. Temperature setpoint has been pre-set at the
factory for optimal operation of the cabinet.
Internal controls will self-regulate the temperature
– no adjustment is necessary.
Model Volts Amps Battery
Type
Battery
Capacity
KCUA11 12VDC 10.5 LiFeP04 38 AH
KCUA11H 12VDC 10.5 LiFeP04 76 AH
Battery Charger 120VAC 3.0 - -
INSTALLATION & OPERATING INSTRUCTIONS
(Continued on Page 3)
Produktspezifikationen
Marke: | Cres Cor |
Kategorie: | Nicht kategorisiert |
Modell: | KCUA11 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Cres Cor KCUA11 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Cres Cor
26 Juni 2025
11 Juni 2025
Bedienungsanleitung Nicht kategorisiert
- M-Audio
- EAS Electric
- Noveen
- TCW Technologies
- Simplicity
- TC Electronic
- Procare
- Festool
- West Elm
- ILive
- Arista
- Saki
- Cinderella
- OWC
- Purell
Neueste Bedienungsanleitung für -Kategorien-
26 Juni 2025
26 Juni 2025
26 Juni 2025
26 Juni 2025
26 Juni 2025
26 Juni 2025
26 Juni 2025
26 Juni 2025
26 Juni 2025
26 Juni 2025