Lies die bedienungsanleitung für CyberPower UT1500E (2 Seiten) kostenlos online; sie gehört zur Kategorie UPS. Dieses Handbuch wurde von 37 Personen als hilfreich bewertet und erhielt im Schnitt 3.7 Sterne aus 19 Bewertungen. Hast du eine Frage zu CyberPower UT1500E oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/2
Copyright © 2023 CyperPower Systems, Inc. All rights reserved. 11F., No.26, Jinzhuang Rd., Neihu Dist., Taipei City 114, Taiwan K01-C000808-00
UT1500E / UT2200E
Users Manual
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual
thoroughly before attempting to unpack, install, or operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the
specifications for the acceptable temperature and humidity range.)
heat emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized
personnel away from batteries.
work inside the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the
skin and eye.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following:
(1) UPS Unit x 1; (2) User Manual x 1; (3) USB Cable x 1
PowerPanel® Personal software is available on our website. Please visit www.cyberpower.com and go to the Software Section for free download.
OVERVIEW
UT1500/2200E series ensure consistent power to your computer system.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery's
maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an
AC outlet. The unit will charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device into the battery power supplied outlets.
DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets.
The power demands of these devices will overload and possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not
service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords.
4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of
equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker / fuse is normal and then turns the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery life.
BASIC OPERATION
1. Power Switch
Press the switch for 2 seconds to turn the UPS ON or OFF.
Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice. The default setting is for the Alarm On. To turn the
Alarm Off, quickly press the power button twice. You will hear two short beeps when the Alarm is turned off. To turn the Alarm back on, quickly press the power
button twice. You will hear a single short beep when the Alarm is turned on.
2. Led Indicators
The LED indicates the status of UPS. Refer to Definitions for Illuminated LED Indicators
section for details.
3. Battery Backup & Surge Protected Outlets
Provide battery backup and surge protection. They ensure power is provided to connected
equipment over a period of time during a power failure.
4. Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, or
network cable.
5. Input Circuit Breaker
The circuit breaker provides optimal overload protection.
6. Input power cord
Connect to utility power.
7. USB Port to PC
This port allows connection and communication from the USB port on the computer to the UPS unit. The UPS communicates its status to the PowerPanel
®
Personal software.


Produktspezifikationen

Marke: CyberPower
Kategorie: UPS
Modell: UT1500E
Breite: 148 mm
Tiefe: 298 mm
Gewicht: 9100 g
Produktfarbe: Schwarz
Höhe: 178 mm
Eingebautes Display: Nein
Betriebstemperatur: 0 - 40 °C
Relative Luftfeuchtigkeit in Betrieb: 0 - 90 %
Zertifizierung: CE
Reaktionszeit: 4 ms
LED-Anzeigen: Leistung
Temperaturbereich bei Lagerung: -20 - 50 °C
Luftfeuchtigkeit bei Lagerung: 0 - 90 %
Geräuschpegel: 45 dB
Ausgangsleistung: 900 W
Nachhaltigkeitszertifikate: RoHS
Eingangsfrequenz: 50/60 Hz
Höhe bei Betrieb: 0 - 3000 m
Anzahl der AC-Ausgänge: 4 AC-Ausgänge
Ausgangskapazität: 1.5 kVA
AC-Steckertypen: Typ F
Output Frequenz: 50/60 Hz
EMI/RFI Lautstärkefilter: Ja
Druckanstiegsschutz: Ja
Nominale Eingang Spannung: 230 V
Höhe bei Lagerung: 0 - 3000 m
Maximaler Eingang Strom pro Phase: 6.82 A
Überspannungsschutz-Funktionen: A/V
Spannunskorrektur Range: -10 - 10 V

Brauchst du Hilfe?

Wenn Sie Hilfe mit CyberPower UT1500E benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten