Daytronic 10A11 Bedienungsanleitung
Lies die bedienungsanleitung für Daytronic 10A11 (6 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 6 Personen als hilfreich bewertet und erhielt im Schnitt 3.5 Sterne aus 3.5 Bewertungen. Hast du eine Frage zu Daytronic 10A11 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/6

1 GENERAL DESCRIPTION AND SPECIFICATIONS
The Model 10A10-4 is a precision conditioner designed for TC-based temperature
measurements requiring
high input isolation. With built-in reference-junction compen-
sation, it accepts up to four independent temperature signals from
Types B, E, J, K, R,
S, and T Thermocouples
. Any desired mixture of these thermocouple types is per-
mitted. Sensors may be grounded or ungrounded, in any desired mix. An amplifier-
per-channel design with chopper stabilization and active low-pass filtering allows
high-speed scan switching of high-level, stabilized signals, at exceptionally low cost
per channel.
All four 10A10-4 inputs are transformer-isolated, so that sensor-to-chassis and/or sen-
sor-to-sensor common-mode voltages as high as 1500 V-DC can be accommodated
at DC or low frequencies without damaging the instrument or perceptibly affecting
measurement accuracy (at 60 Hz, the common-mode voltage can be as high as 1000
V-AC (rms)).
During operation, appropriate reference-junction compensation, real-time digital lin-
earization, and engineering-unit scaling are automatically applied by the System 10
Central Processor for each type of thermocouple used. Detection of “open” thermo-
couples is also provided, as explained in Section 3.a.
The Model 10A10-4 includes a rear-panel connector block with screw terminals for
direct attachment of TC leads (which cannot be soldered). The same connector
accommodates all TC types. Since the connector assembly also contains a dual-
bead
precision thermistor for measurement of the reference-junction temperature,
no external cold junction is required—although the user may supply his own Con-
trolled Ambient Temperature Zone for reference-junction compensation, if desired.
The reference-junction-corrected temperature is made available to the Central
Processor through the
Model 10A11 Thermocouple Output Processor Card. The
purpose of the 10A11 is to proportion and sum the cold-junction reference signal and
the amplified TC signal of each channel for presentation to the system's Analog Signal
Bus.
One 10A11 must therefore be installed in every System 10 A-card rack contain-
ing one or more Model 10A10-4's.
You can use an optional Model 10CTJB-8 Thermocouple Junction Box with a
Model 10A10-4 to move the temperature-compensated reference junction to the actu-
al site of up to eight
remote thermocouple sensors. As explained in Section 4, below,
TC leads connect directly to the 10CTJB-8's internal screw terminals, in any desired
type mixture. The Junction Box then sends their signals to the 10A10-4 Conditioner
via copper conductors (only).*
SYSTEM 10
ANALOG INPUT CARDS
MODEL 10A10-4
QUAD ISOLATED THERMOCOUPLE
CONDITIONER CARD
1.E.2.10A10-4
GENERAL DESCRIPTION AND SPECIFICATIONS 10A10-4.1
* The 10CTJB-8 can only be used in environments with an ambient temperature between 0° F
and +140° F.
Produktspezifikationen
| Marke: | Daytronic |
| Kategorie: | Messung |
| Modell: | 10A11 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Daytronic 10A11 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Daytronic
8 September 2025
8 September 2025
8 September 2025
8 September 2025
7 September 2025
7 September 2025
7 September 2025
7 September 2025
7 September 2025
7 September 2025
Bedienungsanleitung Messung
- Beckmann & Egle
- Axing
- Brandson
- Ermenrich
- Danfoss
- Seek Thermal
- Yato
- Carrier
- Gima
- EAL
- AkYtec
- Bauser
- Megasat
- Westfalia
- Peak
Neueste Bedienungsanleitung für -Kategorien-
20 Januar 2026
20 Januar 2026
20 Januar 2026
20 Januar 2026
20 Januar 2026
19 Januar 2026
19 Januar 2026
19 Januar 2026
19 Januar 2026
18 Januar 2026