Daytronic AA41-2F1 Bedienungsanleitung


Lies die bedienungsanleitung für Daytronic AA41-2F1 (12 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 19 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 10 Bewertungen. Hast du eine Frage zu Daytronic AA41-2F1 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/12
1 GENERAL DESCRIPTION AND SPECIFICATIONS
The Models AA41-2 and AA41-4 are two- and four-channel conditioners (respectively)
for measuring rpm, flow, and other phenomena that can be sensed by pulse trans-
former transducers with 2-wire isolated windings (tachometer pickups, turbine
flowmeters, etc.), transistor or logic-circuit drivers, “zero-velocity” (true digital output)
sensors, and similar
frequency- generating transducers.
The AA41 accepts a wide range of waveshapes and voltage levels. A “Smart Schmitt”
threshold level for each input channel may be individually selected via internal jumper
connections, depending on the expected peak voltage input: 0.1-2 V; 0.5-10 V; 2.5-50
V; or 10-200 V. This ensures reliable triggering when the input is at the low end of the
voltage range. All ranges are protected against an overload of up to 200 V. Nominal
±5 V-DC excitation is supplied for use with a “zero-velocity” sensor.
Standard AA-card “F1” programmable filter tiles let you tailor the dynamic frequency
range and signal response of each AA41 channel to your application’s requirements.*
Setting a frequency channel’s programmable filter to the 1.6-Hz cutoff provides the fol-
lowing input ranges:
10% to 100% of full scale for a range of 250 or 500 Hz
2% to 100% of full scale for a range of 1 or 2 kHz
1% to 100% of full scale for a range of 4, 8, 16, or 32 kHz
If a faster response is more important than dynamic range, you may select a higher
“F1” bandwidth value (see Table 2). However, programmable filter settings above 25
Hz are not recommended for use with the AA41, because of inadequate usable
dynamic frequency range. When the card is used in System 10, its filter cutoff values
are set by means of an on-board 16-position switch for each channel.
Capacitive coupling of 0.1 or 10 microfarads is provided for low-frequency inputs, to
eliminate false triggering by signal noise and/or any positive or negative DC offset that
exists for the frequency signal.** A special trigger-level control guarantees reliable
triggering when the input is at the low end of the frequency range, while a precise
MODEL AA41-2
MODEL AA41-4
FREQUENCY INPUT
CONDITIONER CARD
GENERAL DESCRIPTION AND SPECIFICATIONS AA41-2/4.1
PLEASE NOTE: In this manual, “AA41” will be used to refer to BOTH the two-channel
Model AA41-2 AND the four-channel Model AA41-4, in cases where it is not neces-
sary to distinguish them.
*Or, if desired, a fixed filter of either 10 or 50 Hz for all channels may be specified at the time of
order.
** Noise suppression is always recommended when using a magnetic pickup as the frequency
source.
1.E.2.AA41-2/4
SYSTEM 10
ANALOG INPUT CARDS


Produktspezifikationen

Marke: Daytronic
Kategorie: Nicht kategorisiert
Modell: AA41-2F1

Brauchst du Hilfe?

Wenn Sie Hilfe mit Daytronic AA41-2F1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten