Earthquake Sound SUB-80X Bedienungsanleitung
Earthquake Sound
Subwoofer
SUB-80X
Lies die bedienungsanleitung für Earthquake Sound SUB-80X (4 Seiten) kostenlos online; sie gehört zur Kategorie Subwoofer. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Earthquake Sound SUB-80X oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

Sound That Will YouMove
Sound That Will YouMove
SUB-80X
150 Watt
Digital
Powered
Subwoofer
User's Manual
Earthquake Sound reserves the right to amend details of the specications without notice.
Copyright © Earthquake Sound Corporation
Earthquake Sound Corporation • 2727 McCone Avenue Hayward CA, 94545
Phone: 510-732-1000 Fax: 510-732-1095

Congratulation on your choice of the SUB-80X self powered subwoofer system,
one of Earthquake's newest designs in bass reproduction units.
With an integral high-power amplier - 150 Watts, the SUB-80X subwoofer
combines tight bass extension with high output levels. Acoustically, it is designed
to match typical satellite speaker systems to enhance the over all sound quality
and performance of your system.
Dear Valued Customer,
A) LINE IN RCA - Input jacks, accept up to 1.4 volts of audio input signal (mono
and stereo).
B) LIN OUT RCA - High pass ltered RCA output jacks with left and right line
output signals. The line out RCA's are not functional when the line in signal
(going into the subwoofer) is derived from a sub-ltered output of an external
processor.
C) XOVER FILTER - The 12dB/Octave variable crossover lter is designed to
control the subwoofer cut o frequency (range from: 40Hz to 130Hz).
D) VOLUME CONTROL - Manual adjustment of the sound level of the
subwoofer. Always start at MIN position and slowly increase the volume to reach
the desired subwoofer level.
E) PHASE SHIFT - 0 to 180 degrees subwoofer phase shift switch.
F) POWER SWITCH - For operating the amplier automatic or manual power on.
In automatic mode, the SUB-80X will turn OFF in 15 minutes if no audio signal is
detected.
G), H) POWER INPUT - The SUB-80X operates in 115V and 230V environments.
A sliding switch located near the power plug allows for both operations.
I) HIGH LEVEL OUTPUT - High pass ltered output terminals designed to power
up stereo satellite speakers.
J) HIGH LEVEL INPUT - Clamp style input terminal, accepts high level audio
input from the main or front system speakers (up to 10 volts).
Key Connection and Controls:
Key Connection and Controls:
I
PHASE
AUTO
POWER
HIGH LEVEL INPUT
VOLUME
CROSSOVER
OFF ON
0
O
180
O
120Hz
80Hz
LEFT
FUSE: 115V, T2A/250V
FUSE: 230V, T1A/250V
LEFT RIGHT
RIGHT
HIGH LEVEL OUTPUT
P O W E R E D S U B W O O F E R
DIGITAL
P O W E R
SUB-80X
1 5 0 W A T T S

Subwoofer positioning is integral to the successful application of any surround
sound system. It is very important to keep in mind that the proximity of the
subwoofer to a wall or a corner contributes to an increase in eciency (SPL)
because of the "mirror eect" also referred to as "corner loading".
It is therefore advisable that you place the SUB-80X near a wall, or preferable in
the corner of the room. That will increase the subwoofer effect by 2 to 3 decibels,
without raising the volume control of the SUB-80X.
The ne tuning process includes creating a smooth transition of music between
the subwoofer and the next speaker up: usually a woofer or a mid-range. As
shown in the graph below; a smooth transition between lower and upper bass is
directly relative to the crossover setting and the capability of the next woofer up
to reproduce lower frequencies. Keep in mind that vocals extend down to 70Hz,
adjust your SUB-80X accordingly.
Fine Tuning:
Original Input Signal
Smooth Transition Between
Lower and Upper Bass
IDEAL
CROSSOVER SETTING
LOWER
BASS
UPPER
BASS
Gapped Transition Between
Lower and Upper Bass
OVER GAPPED
CROSSOVER SETTING
LOWER
BASS
UPPER
BASS
Uneven & Gapped Transition
Between Lower and Upper Bass
OVER GAPPED
CROSSOVER SETTING
LOWER BASS ENCROACHING
ON UPPER BASS
LOWER
BASS
UPPER
BASS
CENTERED POSITION
(RECOMMENDED)
WIDE SCREEN /
FLAT PANEL
RIGHT
FRONT
RIGHT
REAR
LEFT
REAR
LEFT
FRONT
SUB-80X
VIEWING POSITION
CORNER LOADING
(HIGHLY RECOMMENDED)
WIDE SCREEN /
FLAT PANEL
RIGHT
FRONT
RIGHT
REAR
LEFT
REAR
LEFT
FRONT
SUB-80X
VIEWING POSITION
VENTILATION DUCT
SUB-80X
BASEMENT LOADING
(STEALTH APPLICATION)
Listening Room & Subwoofer Position: Positioning Examples
Produktspezifikationen
Marke: | Earthquake Sound |
Kategorie: | Subwoofer |
Modell: | SUB-80X |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Earthquake Sound SUB-80X benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Subwoofer Earthquake Sound
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
10 Juli 2025
10 Juli 2025
Bedienungsanleitung Subwoofer
- Phoenix Gold
- Quadral
- Monoprice
- Black Hydra
- Sonance
- Tangent
- Fluance
- Crunch
- Speed-Link
- Insignia
- Match
- KEF
- Soundstream
- Extron
- Rockville
Neueste Bedienungsanleitung für -Kategorien-
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025
11 Juli 2025