Lies die bedienungsanleitung für Extech DV23 (1 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 18 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 9.5 Bewertungen. Hast du eine Frage zu Extech DV23 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/1
DV23enUS_V1.02/15
1
2
3
4
USERGUIDE
DV23 Non Contact VoltageDetector
Safety
Detectoron operation a known livecircuittoverifyproper
WARNING:RiskofElectrocution.Keephandsandfingersonthe
bodyoftheprobeandawayfromtheprobetipandtestedinductor
CAUTION:Read,understandandfollowSafety
RulesandOperating
Instructionsinthismanualbeforeusingthisproduct.
Do not attempt repairs. There are no user serviceable parts.
Do not expose unit to extreme temperatures or high humidity
Do not use the unit if it is wet or damaged
Do not apply more than
the rated voltage between the probe tip
andground.
Do not operatewiththecaseopen.
Thissymbol,adjacent symboltoanother orterminal,
indicatesthe the theuser usermustreferto manualfor
furtherinformation.
Thissymbol,adjacentto a terminal,indicatesthat,under
normaluse,hazardousvoltagesmaybe present.
Doubleinsulationsymbol
Specifications
VoltageSensitivity50V to 600V AC
Bandwidth 50/60Hz
Detectiondistance<0.2”
OperatingTemperature32 to 104
o
F(0to40
o
C)
StorageTemperature 14 to 122
o
F ( 10to50
o
C)
Altitude <7000’ (2000m)
RelativeHumidity < 95% RH
Batteries 2 x 1.5 ‘AAA’ type
Dimensions/Weight 6.25x1” (159x25mm) / 1.5oz (42g)
SafetyThis unit complies with:
EMC:EN613261:2006
LVD:EN61010 1:2010, EN61010 031:2002+1:2008
UL:UL610101,2
nd
Edition, 2005 07 22
CAN/CSAC22.2No.61010 1, 2
nd
edition, 2004 07
Forindooruseandinaccordancewith Overvoltage CategoryIV
600V,PollutionDegree2;conformstoCEstandards
ULListedThe UL mark does not indicatethatthisproducthas
beenevaluatedfortheaccuracyofitsreadings.
1. Pocketclip
2. Batterycompartment
3. Probetip
4. Detectorconelamp
OperatingInstructions
Note:Fornewmeters, andremovethebatteryendcap thenremove
thebattery insulating strip(ifnecessary).
ACVOLTAGEDETECTION
1. the Touch probe conductortip(3)tothehot orinsertintothe
hotsideoftheelectricaloutlet.
2. the IfACvoltage is present, detector cone will
illuminate(4)and
themeterwillbeep.
NOTE:Theconductorsinelectricalcordsetsareoftentwisted.For
bestresults,rubtheprobetipalong a lengthofthecordtoassure
gettingthe thetipincloseproximityto liveconductor.
NOTE:Thedetectorisdesignedwithhigh
sensitivity.Staticelectricity
orothersourcesofenergymay randomly trip the sensor.Thisis
normaloperation.
BATTERYINSTALLATION
1. the Remove endcap(2)bygentlytwisting.
2. InserttwoAAAbatteries(observepolarity).
3. the Replace endcap.
NOTE:Ifthemeterdoesnotworkproperly,check
the thatbatteriestoensure they’refreshand
properlyinserted.
CLEANING
Pleasewipethemeterwith cloth Do a damp asneeded. notuse
solventsorabrasiveswhen cleaning.
Warranty
FLIRSystems,Inc.warrantsthisExtechInstrumentsbranddevice to be free of defects in parts and workmanship
for oneyear fromdate andof appliesshipment(asixmonthlimitedwarranty tosensors cables).Ifitshould
becomenecessary to return the instrument for service during or beyond the warranty
period, contact the
CustomerServiceDepartmentforauthorization.Visit the website www.extech.com for contact information. A
ReturnAuthorization(RA)numbermustbe before anyissued productis isreturned.Thesender responsiblefor
shippingcharges, insurance and damage doesfreight, properpackagingtoprevent intransit.Thiswarranty not
apply
todefectsresultingfromactionof ofthe misuse,user assuch improperwiring,operationoutside
specification,impropermaintenanceorrepair,orunauthorizedmodification.FLIRSystems,Inc.specifically
disclaims specificanyimpliedwarrantiesor ormerchantability fitnessfor apurpose and be any willnot liablefor
direct,indirect,incidentalor
consequential damages. FLIR’s total liability is limited to repair or replacement of the
product.Thewarrantysetforthaboveisinclusiveand no otherwarranty,whetherwrittenororal, orisexpressed
implied.
Calibration,Repair,andCustomerCareServices
FLIRSystems,Inc.offersrepairandcalibrationservicesfortheExtech
Instrumentsproductswesell.NISTcertificationformostproductsisalso
provided.CalltheCustomerServiceDepartmentforinformationon
calibrationservices available for this product. Annual calibrationsshouldbe
performedtoverifymeterperformanceandaccuracy.Technicalsupportand
generalcustomerserviceisalsoprovided,refertothecontactinformation
providedbelow.
Copyright ©2015FLIRSystems,Inc.
Allrights rightreservedincludingthe ofreproductionin inwholeorinpart anyform
www.extech.com
Support Lines: U.S.(877)439 8324; International:+1 (603) 324 7800
TechnicalSupport: mail: [email protected]Option3;E
Repair Returns: &Option4;Email:re[email protected]om
Productspecificationsare subject tochangewithoutnotice
Pleasevisitourwebsiteforthemostuptodateinformation
www.extech.com
FLIRCommercialSystems,Inc., 9
TownsendWest,Nashua,NH03063
ISO9001Certified


Produktspezifikationen

Marke: Extech
Kategorie: Messung
Modell: DV23

Brauchst du Hilfe?

Wenn Sie Hilfe mit Extech DV23 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten