Extron DTP3 IN2004 Bedienungsanleitung


Lies die bedienungsanleitung für Extron DTP3 IN2004 (6 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 5 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 3 Bewertungen. Hast du eine Frage zu Extron DTP3 IN2004 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/6
1
IN2004 Series • Setup Guide
IMPORTANT NOTE:
Go to www.extron.com for the complete IN2004 Series user guide, installation instructions, and specications
before connecting the product to the power source.
The Extron IN2004 Series are compact, four-input scaling switchers that support video resolutions up to 4K @ 60 Hz at 4:4:4 color
sampling. Integrating HDMI and audio sources into presentation systems, they incorporate Extron-patented Vector™ 4K scaling
technology specically engineered for critical video processing applications. The IN2004 Series deliver automatic switching and
provide advanced features such as seamless transition e󰀨ects, logo keying, congurable input loop-through, audio embedding and
de-embedding, mixing, and ducking. With these capabilities and more, the IN2004 Series are ideal for board rooms, collaboration
spaces, and other professional AV venues. For lecture halls and larger installations spanning long distances, the DTP3 IN2004 DO
and DI/DO models with DTP3 extension of AV and control signals are also available.
The IN2004 Series scalers provide audio signal processing and control by allowing adjustment of the input audio format, audio gain
and attenuation, mixing, ducking, audio muting, analog output format, and output volume. The stereo and dual independent mono
balanced and unbalanced analog audio line input can be mixed with program audio or audio le playback. The IN2004 Series
scalers have two audio output paths: Digital Out 1A/1B and an analog 5-pole captive screw output on the rear panel. These two
output groups each have unique DSP functions for mixing, ltering, and dynamics. Each individual output connector supports
discrete audio mute control. Audio settings are made via Extron Simple Instruction Set™ (SIS) and Product Conguration Software
(PCS) (see the IN2004 Series User Guide and the IN2004 Series Help File for more information).
NOTE: For full installation, conguration, and operation details, see the IN2004 Series User Guide at www.extron.com. For
information on conguration using PCS, see the IN2004 Series Help File within the software.
Installation
Rear Panel Features
The IN2004 Series models have di󰀨erent rear panel inputs and outputs as described below. Figure 1 shows the
DTP3 IN2004 DI/DO model as an example, because it contains all connector types available on the IN2004 Series.
IN2004 standardInputs: Four HDMI. Outputs: Two HDMI.
DTP3 IN2004 DO Inputs: Four HDMI. Outputs: Two HDMI and one RJ-45
twisted pair for DTP, DTP3, XTP, and HDBT output (mirrors the output of the scaler).
DTP3 IN2004 DI/DO Inputs: Four HDMI and one RJ-45 twisted pair for DTP,
DTP3, or XTP input (congurable to use in place of HDMI input 4)
Outputs: Two HDMI and one RJ-45 twisted pair for DTP, DTP3, XTP, and HDBT
output (mirrors the output of the scaler).
100-240V
~
1.4A MAX
50-60Hz
INPUTS
CONTACT
AUDIO
REMOTE
OUTPUTS
1 2 3 4
4
1A 1B
CONFIGURABLE
1C
CT1 GV+CT2 CT3 CT5 CT6 CT7CT4
1IN2 1OUT 2
IN
SIGLINK
OUT
SIGLINK
RS-232
Tx Rx G
LAN
RESET
A
C
B
D
E
H
J
I
L
P
K
M
N
O
F
G
Figure 1. Rear Panel Connectors — DTP3 IN2004 DI/DO
Mounting and Cabling
Step 1 — Mount the device
a. Turn o󰀨 or disconnect all equipment power.
b. Place the scaler on top of a flat surface using the provided rubber feet, mount it under a table using an optional kit for under
desk mounting, or attach it to a rack shelf using an optional rack shelf-mounting kit (kits are available at www.extron.com).
A
AC power connector
B
HDMI INPUTS
C
HDMI input 4
D
TP RJ-45 input 4
E
TP RJ-45 output 1C
F
HDMI output 1A
G
CONFIGURABLE HDMI output 1B
H
LAN connector
I
RESET button
J
RESET LED
K
REMOTE RS-232 connector
L
Analog AUDIO output
M
Analog AUDIO input
N
+V port (for tally voltage output)
O
Ground pin (for contact ports)
P
Contact/tally connectors
1
2
Step 2 — Connect inputs
Connect one or more input sources as appropriate.
NOTE: Securing the HDMI cables with the provided LockIt Pro brackets is recommended (see the IN2004 Series User Guide
for instructions).
Connect HDMI or DVI (with an appropriate adapter) video sources to HDMI inputs 1, 2, and 3.
DTP3 IN2004 DI-DO only Connect an HDMI source to the input 4 HDMI connector (see gure1,
C
on the previous page),
or
Connect a DTP or DTP3 transmitter or XTP II matrix switcher to the twisted pair IN connector (
D
). For cable wiring, see
Twisted Pair Recommendations for the IN and OUT TP Connectors on page 3.
The DTP3 IN2004 models can remotely power DTP and DTP3 endpoints. To set the remote power level (12 V or 48 V),
use the DTP Remote Power Input SIS commands (see the IN2004 Series User Guide at www.extron.com to enter these
commands), or use PCS (see the IN2004 Series Help File). The IN2004 Series does not remotely power XTP II or HDBaseT
endpoints.
Connect a balanced or unbalanced audio source to the 5-pole captive screw AUDIO IN connector (
M
). See Audio Wiring on
page 4 for more information.
NOTE: Audio inputs 1 and 2 can act as two independent mono inputs or can be grouped to act as a stereo input.
Step 3 — Connect outputs
Connect one or two sink devices as appropriate:
Connect HDMI sink devices (or DVI, with an appropriate adapter) to the rear panel HDMI outputs 1A (
F
) and 1B (
G
). Secure
the HDMI cables with the provided LockIt Pro brackets (see the IN2004 Series User Guide for instructions).
NOTE: By default output 1B mirrors scaler output 1A, but using PCS or SIS commands, output 1B can be congured to
pass a non-scaled loop-out of any input.
DTP3 IN2004 DO and DTP3 IN2004 DI/DO only — Connect a DTP or DTP3 receiver, XTP II matrix, or HDBaseT-compatible
device to the twisted pair OUT connector (
E
). For cable wiring and recommendations, see Twisted Pair Recommendations
for the IN and OUT TP Connectors.
The DTP3 IN2004 models can remotely power DTP and DTP3 endpoints. To set the remote power level (12 V for DTP or
48 V for DTP3), use the DTP Remote Power Output SIS commands (see the IN2004 Series User Guide at www.extron.com
to enter these commands) or PCS (see the IN2004 Series Help File). The IN2004 Series does not remotely power XTP II or
HDBaseT endpoints.
Connect a balanced or unbalanced audio output device to the 5-pole captive screw AUDIO OUT connector (
L
). See Audio
Wiring on page 4 for more information.
NOTE: Audio outputs 1 and 2 can act as two independent mono outputs with unique mixing, levels, and mutes, or they
can be grouped as a stereo output pair.
Step 4 — Connect control devices
NOTE: The factory congured passwords for all accounts on this scaler have been set to the serial number. In the event of
a complete system reset, the password converts to the default, which is extron. New passwords must be congured to
secure the device.
a. To control the IN2004 Series through Ethernet, connect a LAN to the RJ-45 LAN connector (
H
). The default IP address of the
scaler is 192.168.254.254, the default subnet mask is 255.255.255.0, and the default gateway address is 0.0.0.0.
Connect using a web browser, PCS, or an SSH via SIS client (port 22023), or using Telnet (disabled by default, see the IN2004
Series User Guide to enable it).
b. For bidirectional RS-232 control, connect a host to the 3-pole captive screw connector (
K
). The baud rate is 9600.
c. For control through USB, connect a host device to the front panel USB-C port (see figure 2,
A
, on page 4). The IP address
for the CONFIG port is 203.0.113.22. This address cannot be changed. Connect using a web browser, PCS, or an SSH via
SIS client (port 22023).


Produktspezifikationen

Marke: Extron
Kategorie: Nicht kategorisiert
Modell: DTP3 IN2004

Brauchst du Hilfe?

Wenn Sie Hilfe mit Extron DTP3 IN2004 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten