Festo MS9-SV Bedienungsanleitung
Festo Nicht kategorisiert MS9-SV
Lies die bedienungsanleitung für Festo MS9-SV (4 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 15 Personen als hilfreich bewertet und erhielt im Schnitt 3.9 Sterne aus 8 Bewertungen. Hast du eine Frage zu Festo MS9-SV oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

MS9-SV-...-C
Soft start/quick exhaust valve
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Operating instructions
8164018
2022-06a
[8164020]
Translation of the original instructions
© 2022 all rights reserved to Festo SE & Co. KG
1About this document
This document describes the use of the soft start/quick exhaust valve.
The document contains additional information for use of the product in safety-
related systems (safety handbook in accordance with IEC 61508).
1.1Target group
The document is targeted towards individuals who mount and operate the
product. It is additionally targeted towards individuals who are entrusted with
the planning and application of the product in a safety-oriented system.
1.2Applicable documents
–Assembly instructions for cover MS6/9-SV-C-MK/MH as tamper protection
All available documents for the product
è www.festo.com/sp.
1.3Specified standards
Version
EN 60204-1:2016-10EN ISO 13849-2:2012-10
EN ISO 4414:2010-11EN ISO 14118:2018-02
EN ISO 13849-1:2015-12
Tab. 1:Standards specified in the document
2 Safety
2.1Safety instructions
–Only use the product in its original condition without unauthorised modifica-
tions.
–Only use the product if it is in perfect technical condition.
–Observe the identifications on the product.
–Take into account the ambient conditions at the location of use.
–Before working on the product, switch off the power supply and secure it
against being switched on again.
–Observe the tightening torques. Unless otherwise specified, the tolerance is
± 20%.
–Only use compressed air as an operating medium in accordance with the speci-
fication è 12 Technical data.
2.2Intended use
The product is intended for mounting in machines or automation systems and is
only to be used as follows:
–in an industrial environment
–in its original condition, without unauthorised modifications
–in safety-related systems only with cover MS9-SV-MK as tamper protection
–in perfect technical condition
2.3Foreseeable misuse
Foreseeable misuse includes:
–outdoor operation
–Bypassing of safety functions
–use in reversible operation with reversal of supply air and exhaust air
–use in "Low Demand Mode" according to EN 61511
–vacuum operation
2.4Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with electropneumatic (open-loop) control technology.
3Additional information
–Contact the regional Festo contact if you have technical problems
è www.festo.com.
–Accessories è www.festo.com/catalogue.
Designation Type
Silencer U-1-B
Cover, covers the manual overrideMS9-SV-MH
Cover, covers the adjustment elements for the pressure switching point, the
main flow control and the manual override
MS9-SV-MK
Tab. 2:Accessories
4Product overview
4.1 Structure
4.1.1Product design
1
2
3
4
5
6
7
8
9
Fig. 1:Operating elements and
connections
1
Pilot solenoid valve
2
Manual override at the soft-start/quick
exhaust valve
3
Pneumatic port 1 (compressed air
inlet)
4
Pneumatic port 3 (exhaust)
5
Silencer
6
Manual override at the pilot solenoid
valve
7
Flow control screw for setting the
filling time
8
Adjusting screw for setting the pres-
sure switch point
9
Pneumatic port 2 (compressed air
outlet port)
4.1.2Product variants
The following table lists selected product characteristics and codes that are
necessary for understanding the instruction manual. Complete type code
è www.festo.com/catalogue.
Key featuresCodeDescription
SeriesMSStandard service unit
Size9Grid dimension 90 mm
Function-SVSoft-start/quick exhaust valve
Port size-3/4Thread G 3/4
-1Thread G 1
-AGDSub-base G 1/2
-AGESub-base G 3/4
-AGFSub-base G 1
-AGGSub-base G 1 1/4
-AGHSub-base G 1 1/2
-N3/4Thread N 3/4
-N1Thread N 1
-AQRSub-base NPT 1/2
-AQSSub-base NPT 3/4
-AQTSub-base NPT 1
-AQUSub-base NPT 1 1/4
-AQVSub-base NPT 1 1/2
-GModule without connection thread, without sub-base
-NGModule without connection thread, without sub-base (port 3 in
NPT)
Performance Level-Cin accordance with EN ISO 13849-1
Supply voltage-V2424 V DC (plug pattern in accordance with EN 175301-803, type C)
-10V24P24 V DC (M12 in accordance with IEC 61076-2-101)
-V110110 V AC (plug pattern in accordance with EN 175301-803,
type C)
-V230230 V AC (plug pattern in accordance with EN 175301-803,
type C)
Options-S Silencer
Tamper protection-MHCover - manual override (HHB) only
-MKCover – pressure switching point (DUP) and main flow control
valve (HD) adjusting screws, manual override (HHB)
Tab. 3:Product variants (selection)
4.2 Function
The MS9-SV-...-C electro-pneumatic pressure soft-start/quick exhaust valve is
intended for rapid pressure reduction and pressurisation in pneumatic line sys-
tems and terminal equipment in industry.
Produktspezifikationen
| Marke: | Festo |
| Kategorie: | Nicht kategorisiert |
| Modell: | MS9-SV |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Festo MS9-SV benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Festo
1 August 2025
1 August 2025
1 August 2025
1 August 2025
1 August 2025
1 August 2025
1 August 2025
1 August 2025
1 August 2025
1 August 2025
Bedienungsanleitung Nicht kategorisiert
Neueste Bedienungsanleitung für -Kategorien-
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026
21 Januar 2026