Lies die bedienungsanleitung für Intermatic ET2125C (8 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 1.5 Bewertungen. Hast du eine Frage zu Intermatic ET2125C oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/8

Electronic 2-Circuit
24-Hour Time Switch
Installation and Setup Instructions
With 100-Hour Backup
Federal Communications Commission (FCC) Notice for ET2000 Series Time Switches
Description
This document explains the setup and conguration of the Intermatic ET2125 2-Circuit
Electronic 24-Hour Time Switch. The ET2125 time switch automatically switches loads
according to the entered schedule. The time switch can support up to 48 xed ON daily
and 48 xed OFF events (96 total).
The time switch features an LCD and panel-mounted control buttons to set, review, and
monitor the time switch functions, including setting date and time, schedule creation,
enabling or disabling Daylight Saving Time (DST) and conguring DST switchover dates.
Follow these instructions to complete the installation and programming of the ET2125 time
switch.
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference, including interference that may cause
undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and radiates radio frequency energy and, if
not installed and used in accordance with instructions, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference that requires the user to correct at his or her own expense.
MODELS ET2125C, ET2125CR, ET2125CP
Shown in indoor/outdoor
lockable metal enclosure
NOTICE
• Do NOT touch circuit board components, contact can create a static discharge, which can damage these electronic components.
• Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
• More than one circuit breaker or disconnect switch may be required to de-energize the equipment before servicing.
• For plastic enclosures, bonding between conduit connections is not automatic and must be provided as part of the installation.
• Installation and/or wiring must be in accordance with National and Local Electrical Code requirements.
• Use #14-#8 AWG wires, rated at least 105°C - COPPER conductors ONLY.
• If the power disconnect point is out of sight, lock it in the OFF position and tag it to prevent unexpected application power.
• Make sure there is no wire insulation under the terminal plate on the time switch connector. Firmly tighten terminal screws.
• For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for fitting conduit and
outlet boxes) are to be used.
• Do not remove insulator that is covering terminals.
• Do NOT exceed maximum current carrying capacity.
• KEEP DOOR CLOSED AT ALL TIMES when not servicing.
Risk of Fire or Electric Shock
WARNING

Snap out catch
Tilt top forward
Installation
Follow these instructions to install the time switch.
1. Open the time switch enclosure door.
2. Remove and retain the screw that secures the plastic insulator.
3. Lift the left side of the plastic insulator and pivot away to expose the terminal strip.
4. Press the latch at the top of the enclosure and pull out the mechanism from the
enclosure.
5. Choose and remove the selected knockout(s) from the enclosure.
NOTE: There are ve 1/2 inch to 3/4 inch combination knockouts available. There are
two on the bottom of the enclosure, one on each side, and one on the rear. If a 3/4
inch knockout is needed, remove the 1/2 inch knockout rst, then the 3/4 knockout.
6. Place the enclosure in the desired location providing space for the enclosure door to
swing open fully.
7. Securely mount enclosure using provided mounting holes.
8. Use appropriately rated ttings for the installation.
9. Snap the mechanism back into the enclosure.
10. Strip 1/2 inch off the supply and load wires. Use AWG #14-#8 copper conductors
rated at least 105ºC.
11. Connect the wires to the proper terminals on the time switch and tighten the screws
rmly (See wiring diagrams).
12. Connect ground wire to grounding terminal at the bottom of metal enclosures.
13. Return the insulator to its original position and replace the screw.
14. Close enclosure door.
15. Apply power to the time switch.
Wiring Diagrams
1/2 inch
OUTPUT 1
OUTPUT 2
OUTPUT
1 & 2
OUTPUT
1 & 2
AC IN
NO-1 NO-2COM1 COM2
CIRCUIT 1 CIRCUIT 2TIMER
POWER
L1
L2/N
TIMER CONFIGURATION FOR LATCHING MECHANICALLY
HELD CONTACTOR CONTROL
COM
CLOSE
OPEN

Initial Setup
The following sections provide instructions for the initial setup of the time switch.
Setting The Output Configuration
The time switch output conguration enables users to control multiple loads simultaneously (SIM), independently (IND), or with a
2-second pulse (PUL). Output circuits are congured in pairs.
In PUL mode, an ON event or manual override, causes circuit #1 to turn ON for two seconds, then OFF. An OFF event, or manual
override, causes circuit #2 to turn ON for two seconds, then OFF.
NOTE: The output conguration setup can only be accessed at initial startup of the unit or after a “Clearing Time Switch Memory”
operation. Follow this procedure to set the output conguration.
1. Activate power to the time switch. The display shows IND, the icon above the ENTER/NEXT button and the LOAD ARROW
icons for circuit #1 and circuit #2 turn on.
NOTE: If the display does not show the output conguration is already set and a “Clearing Time Switch Memory” operation IND
must be performed.
2. Press + or - to scroll to the desired output conguration.
3. Press ENTER/NEXT to save the setting.
4. The output conguration is now completed.
Programming Overview
The steps to program the time switch include setting the current date, time, xed events, DST, and holiday events, setting the time
switch’s operation to AUTO mode, ENERGY SAVER mode or MANUAL mode (only MANUAL mode will appear if there are no
scheduled events) and read or write an event schedule from a USB memory stick.
NOTE: If the time switch is left inactive for ve minutes in a programming mode, it will return to the AUTO mode screen ( icon AUTO
turned on). If no scheduled events are programmed, the time switch will return to MANUAL mode. If the date has not yet been
entered, the time switch will go to the Enter Date Mode.
Setting Date
Follow this procedure below to set the date and time in the time switch.
NOTE: If necessary, hold + or - to scroll through the digits rapidly.
1. Press MODE to scroll through the mode selections until and icons appear at the top of the display. The month SET DATE
ashes.
2. Press + or - to select the current month and then press ENTER/NEXT. The day of the month ashes.
3. Press + or - to select the current day of the month, and then press ENTER/NEXT. The year ashes.
4. Press + or - to enter the current year, and press ENTER/NEXT. The month will ash again.
5. Press MODE to move to the next mode selection.
Setting Time
Follow the procedure below to set the time in the time switch.
NOTE: If necessary, hold + or - to scroll through the digits rapidly.
1. Press MODE to advance to the Set Clock mode selection if this selection is not already active. The and SET TIME icons appear
on the display and a ashing 12:00 AM appears (if clock has not been set).
2. Press + or - to select the current time. Seconds can be set to 00 by pressing ENTER/NEXT.NOTE:
3. Press MODE to save the time and move to the Enable Daylight Saving Time mode selection.
NOTE: If the time switch programming data is to be read from a USB memory stick, refer to the “Read Time Switch Program
Data…” section in these instructions.
Produktspezifikationen
Marke: | Intermatic |
Kategorie: | Nicht kategorisiert |
Modell: | ET2125C |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Intermatic ET2125C benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Intermatic
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
Bedienungsanleitung Nicht kategorisiert
- Bicker Elektronik
- Radial Engineering
- G3
- VMV
- ESYLUX
- Atlona
- Banana Pi
- UNYKAch
- Furman
- Axagon
- Wiltec
- Gram
- Hisense
- Waterdrop
- Nexera
Neueste Bedienungsanleitung für -Kategorien-
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025