Lies die bedienungsanleitung für Klein Tools ET120 (13 Seiten) kostenlos online; sie gehört zur Kategorie Gasdetektor. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 5.0 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Klein Tools ET120 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/13
INSTRUCTION MANUAL
FRANÇAIS pg. 13
ESPAÑOL pg. 7
Combustible Gas
Leak Detector
DETECTS A RANGE
OF COMBUSTIBLE
GASSES
AUDIBLE AND
DATA HOLD
ENGLISH
2m
ET120
2
GENERAL SPECIFICATIONS
Klein Tools ET120 is an easy-to-use tester that provides audible and
visual alarms in the presence of methane, propane and butane at
concentrations as low as 50 ppm.
Audible Alert: 85 db ticking, modulation proportional to gas
concentration
Visual Alert: 5 x red LED,
illumination proportional to gas concentration
Range*: 50 to 10,000 ppm
LOW sensitivity* (white light): 1,000 to 10,000 ppm
HIGH sensitivity* (yellow light): 50 to 1,000 ppm
Initial calibration: 50 seconds to zero calibration
Response time (after calibration): 3 seconds
Sensor: Electrochemical
Sensor Life expectancy: 5 to 7 years
Probe: 18" (457 mm) gooseneck
Batteries: 4x AAA alkaline
Operating Altitude: 6562 ft. (2000 m)
Relative Humidity: <80% non-condensing
Operating Temp: ° ° ° °32 to 122 F (0 to 50 C)
Storage Temp: ° ° ° °-4 to 122 F (-20 to 50 C)
Dimensions: 8.11" x 2.72" x 1.75" (206 x 69 x 45 mm)
Weight: 15 oz. (425 g) including batteries
Tripod Mount: 1/4-20 UNC
Drop Protection: 6.6 ft. (2m)
*Based on Methane. Other gasses or mixtures will have different values.
Specifications subject to change.
WARNINGS
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe
injury or death. High concentrations of combustible gasses can
cause explosions,  res, asphyxia, and other hazards that could cause
serious personal injury or death. Know the characteristics of the gas
you are working with and use proper precautions to avoid hazardous
conditions.
Read, understand, and follow all instructions to ensure safe operation.
Always turn on the gas detector in an area known to be free of combustible
gasses.
Initial calibration should be performed in an area known to be free of
combustible gasses. Calibration in an area containing combustible gas will
result in incorrect calibration and lower than actual readings. This could
result in combustible gasses not being detected.
The combustion gas leak detector is NOT intended as a personal protection
device (PPE).
Do NOT replace batteries in an explosive atmosphere.
The combustion gas leak detector is NOT insulated. Avoid contact with
areas where energized conductive elements may be present. Shut off
power to the area before starting measurements.
Do NOT probe moving machinery that could catch any part of the meter
and cause harm to the operator and the meter.
Always wear approved eye protection.
ENGLISH
4
FUNCTION BUTTONS
AUTO-ZERO BUTTON
7
Press to set zero point calibration in a known clean environment.
MUTE BUTTON
8
Press to mute the audible alarm. Visual indicators will continue to
function as normal
.
AUTO POWER-OFF (APO) BUTTON
9
Press to enable or disable the Auto Power-Off feature. When enabled,
the button will illuminate blue, and the tester will automatically power
off after 10 minutes of inactivity.
LOW BUTTON
10
Press to enter Low Sensitivity mode (1,000 to 10,000 ppm). White light
will blink.
HIGH BUTTON
11
Press to enter High Sensitivity mode (50 to 1,000 ppm). Yellow light will
blink.
HOLD BUTTON
12
Press to lock the current measurement on the screen. Press again to
return to taking active measurements.
POWER BUTTON
13
Press and hold for 3 seconds to turn tester on or off.
ENGLISH
SYMBOLS ON METER
Warning
Risk of
Electric Shock
Wear approved eye protection
Explosive Materials
Read instructions
Not intended for use as Personal
Protective Equipment (PPE)
Do NOT probe
moving machinery