Lies die bedienungsanleitung für Panasonic EX-F1 (1 Seiten) kostenlos online; sie gehört zur Kategorie Messgeräte. Dieses Handbuch wurde von 42 Personen als hilfreich bewertet und erhielt im Schnitt 4.4 Sterne aus 21.5 Bewertungen. Hast du eine Frage zu Panasonic EX-F1 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/1
Thank you very much for purchasing Panasonic products.
Please read thisInstructionManualcarefullyand thoroughly
for the correct and optimum use ofthis product. Kindlykeep
this manualin a convenient place for quickreference.
SPECIFICATIONS1
0.1mm
2
3-core cabtyre cable, 1m long
Cable
Red LED (lights upwhen the output is ON)
Operation indicator
0.5mm or lessRepeatability
Enclosure: Polycarbonate
Tying band: Nylon
Anti-slip tube: Silicone
Material
15g approx.Weight
Tyingband:2pcs., Anti-sliptube:2 pcs.Accessories
Infrared LED (modulated)
2ms or lessResponsetime
-10 to +55(No dew condensation or
icing allowed), Storage: -20 to +70
Ambient temperature
(Note 3)
35 to 85% RH, Storage: 35 to 85% RHAmbient humidity
Emitting element
Incorporated
Output
Short-circuit protection
Switchableeither Light-ON or Dark-ONOutput operation
NPNopen-collector transistor
Maximum sink current: 100mA
Applied voltage:
30VDC or less
(betweenoutputand 0V)
Residual voltage:
1V or less (at 100mA sink current)
0.4Vorless(at16mA sinkcurrent)
Current consumption
12 to 24VDC±10% Ripple P-P 10% or less
30mA or less
Supply voltage
Liquid (Note 1)Sensing object
Outer diameter φ6 to φ13 mm transpar-
ent resin pipe [PFA(Fluorine resin) or
equivalent, having the same transparen-
cy, thickness 1mm] (Note 2)
Applicable pipediameter
EX-F1
Amplifier built-inpipe-mountable liquid
level sensor
Designation
Model No.Item
Notes: 1)
2)
3)
Unclearorhighlyviscousliquidmaynotbe detectedstably.
Donot use thesensor withpipes other thanthe above
specified. Furthermore, takecare that ifthe pipe ismade
fromglass,the detectionmaybe unstableduetorefraction.
Liquidbeingdetected should alsobe keptwithin therated
ambient temperature range.
MOUNTING ON A PIPE4
Mount the sensor on a pipe with the attached tying
bands andanti-sliptubes asshown inthefigure be-
low. Makesure therelease lever isretracted (position
asinthe figure)beforemounting.
Fasten two tying bands, as shown, and cut off the ex-
cess portions.
Upper hold
Lower hold
Anti-slip tube
Tying band
Release lever
Ifothertyingbandsare tobeused, thedimension
shown in the figure below should be 2.5mm or less.
A
DIMENSIONS(Unit: mm)7
Beam axis
13
8
15
4
Operation mode
switch
Beam axis
27
13
Operationindicator (Red)
φ2.5cable 1mlong
2923
Never use this productas a sensing de-
vice for personnel protection.
Incase ofusingsensingdevicesforpersonnelpro-
tection,use productswhichmeet laws and stand-
ards, such as OSHA, ANSI or IEC etc., for personnel
protectionapplicablein eachregionorcountry.
WARNING
I/O CIRCUIT DIAGRAM2
Symbols...D
Z
D
T
r
: Reverse supply polarity protection diode
: Surge absorption zener diode
:NPNoutput transistor
(Brown) +V
(Black) Output
(Blue) 0V
Color code
D
Z
D
T
r
Load 12 to 24V DC
±10%
+
-
100mA max.
Users' circuitInternal circuit
Sensor circuit
EX-F1 does notprovide water-tightness, oil-resistance
or chemical-resistance. Avoid installation at any place
that itcould be exposed towater, chemical or oil.
CAUTIONS3
This product has been developed/ producedfor industrial use only.
The thin cable (0.1mm
2
) isused for this product.Thus,
take carethat ifthecable ispulled withexcessive
force, itmay cause cable break.
Make sure that the power supplyis off while wiring.
Takecare thatwrongwiringwilldamage thesensor.
Verify that the supply voltage variationis withintherating.
If power issupplied from a commercial switching regu-
lator,ensurethat theframe ground(F.G.)terminalof
the powersupply isconnected to an actual ground.
In case noise generating equipment (switching regula-
tor,invertermotor,etc.)isusedin thevicinityofthis
product,connect the frameground (F.G.) terminal of
the equipment to an actualground.
Do notrun thewires togetherwith high-voltagelines or
power lines orput themin thesame raceway. This can
cause malfunction due to induction.
Extension up tototal 50m, is possible with 0.3mm
2
, or
more, cable forboth, emitter and receiver.However, in or-
der to reduce noise, make the wiring as shortas possible.
Do not useduring the initial transient time (50ms)after
thepower supplyisswitchedon.
Take care that the sensor isnotdirectlyexposed to
fluorescentlamp from a rapid-starter lamp, a high fre-
quency lighting deviceor sunlight etc., asit may affect
the sensing performance.
Thissensor issuitableforindooruseonly.
Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
Since the cable end is not waterproof,do not use the sensor in
the application where water may seep in from the cable end.
This sensor cannot be used with a non-transparent pipe.
Fit thesensortoapipesecurely,otherwise theopera-
tion may be erroneous.
If a liquid drop flows down acrossthe sensing point oran
air bubble sticks on the wall at thesensing point, the opera-
tion may be aected. Make sure that no bubble formsin the
liquid,and nodeworliquiddropattaches oneithersurface.
Inner wall
Liquid dropsOuter wall
Air bubbles
POSITION ADJUSTMENT5
Afteritismountedon thepipewith tyingbands,the
sensor position can be easilyadjusted.
Unlockthe release lever
(in the directionof the
arrow).
Pressthemovable cen-
ter holdersforward to
loosen thetyingbands
and adjust the position.
Lockthe release leverto
its original place.
Adjustment
Note: Thelevermechanismmustbeusedonlytoadjusttheposition,
and notfor tightening thetying bands.If tyingbands are tightened
while the lever isopen, and then the lever is locked, the sensor
maybe damaged.
Press
Loose
Position
adjustable
Release lever
SELECTING OUTPUT OPERATION
6
EitherLight-ON (Liquid-absent-ON)or Dark-ON
(Liquid-present-ON) can be selected with theopera-
tion mode switch according to your application.
The indicator operation and the output operation
change with the setting ofthe operation mode
switchasgiveninthe tablebelow.
Liquid-absent Liquid-persent
Operation mode switch
L :Low-level-ON
D: High-level-ON
Operation indicator (Red)
Lightsup whenthe
output isON.
Output operation
Sensing condition
MODE
Operation indicator
OFFLiquid-present
Light-ON
(Liquid-absentl-ON)
ONLiquid-absent
ONLiquid-present
Dark-ON
(Liquid-persent-ON)
OFFLiquid-absent
: Lightsup,: Turns off
INTENDED PRODUCTSFOR
CE MARKING
8
The models listed under'SPECIFICATIONS'
come with CE Marking.
As for all other models, pleasecontact ouroffice.
1
Pipe-mountable Liquid Level Photoelectric Sensor
EX-F1
INSTRUCTION
MANUAL
© PanasonicElectricWorks SUNX Co., Ltd. 2011
PRINTED IN JAPAN
http://panasonic-electric-works.net/sunx
OverseasSalesDivision (HeadOffice)
2431-1Ushiyama-cho,Kasugai-shi, Aichi,486-0901,Japan
Phone: +81-568-33-7861FAX: +81-568-33-8591
Europe Headquarter:PanasonicElectricWorks Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
Phone: +49-8024-648-0
US Headquarter:PanasonicElectricWorksCorporationof America
629 CentralAvenue New Providence, New Jersey07974 USA
Phone: +1-908-464-3550