Lies die bedienungsanleitung für Sanwa CD800a3 (1 Seiten) kostenlos online; sie gehört zur Kategorie Multimeter. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 2 Bewertungen. Hast du eine Frage zu Sanwa CD800a3 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/1
1) Prior to requesting repair, please check the following:
Capacity of the built-in battery, polarity of installation and discontinuity
of the test leads.
2) Repair during the warranty period:
The failed meter will be repaired in accordance with the conditions
stipulated in 7-1 Warranty and Provision.
3) Repair after the warranty period has expired:
In some cases, repair and transportation cost may become higher than
provider in advance. The minimum retention period of service functional
parts
is 6 years after the discontinuation of manufacture. This retention period
is the repair warranty period. Please note, however, if such functional parts
become unavailable for reasons of discontinuation of manufacture, etc.,
the retention period may
become shorter accordingly.
4) Precautions when sending the product to be repaired
To ensure the safety of the product during transportation, place the product in a box
that is larger than the product 5 times or more in volume and ll cushion materials
fully and then clearly mark “Repair Product Enclosedon the box surface. The cost
of sending and returning the product shall be borne by the customer.
INSTRUCTION MANUAL
1 SAFETY PRECAUTIONS B
efo , r ee us r theead fo w llo ing safety precau iot ns.
1-1 Explanation of Warning Symbols
The meaning of the symbols used in this manual and attached to the
product is as follows.
Very important instruction for safe use.
The warning messages are intended to prevent accidents to
operating personnel such as burn and electrical shock.
The caution messages are intended to prevent damage to the instrument.
Ground Diode Fuse
Ω:Buzzer Capacitance Resistance
HzDirect current (DC) Frequency
〜:Duty cycle Alternating current (AC)
Backlight EF antenna
Double insulation (Protection Class)
−:Plus input (Red) Minus input (Black)
1-2 Warning Instruction for Safe Use
To prevent injuries such as burns or electric shocks, ensure strict compliance
with the following instructions when using this instrument:
1.
Do not input signals exceeding the maximum rated input value (see 1-3).
2 t . Do not use the instrument to measure lines connected to equipmen
(e.g., motors) that may generate induced or surge voltages, as these
may exceed the maximum allowable input.
3.
Do not use the instrument if the main unit or test leads are damaged or
broken.
4. Do not use the instrument with the case or battery cover removed.
5. Always use fuses of the specied rating and type. Never substitute
fuses or short-circuit the fuse terminals with wire.
6. When measuring, keep your ngers behind the nger guards on the
test probes.
7.
When connecting test leads, connect the ground lead (black) rst. When
disconnecting, remove the ground lead last.
8. Do not switch functions or ranges during measurement.
WARNING
2 APPLICATION AND FEATURES
2-1 Applications
This instrument is a true RMS digital multimeter designed for measurements
within the CAT. IV 600 V range.
9. Always conrm the correct function and range settings before
starting a measurement.
10. Do not use the instrument with wet hands or in damp conditions.
11. Use only the specied type of test lead.
12.
Do not perform repairs or modications, except for replacing the battery or fuse.
13.
Do not use the instrument near devices that emit strong electromagnetic
waves or are electrically charged.
14. Inspect the instrument at least once a year.
15. Use the instrument indoors only.
Function
V
DCAC 600.0 V
DC 600 V
AC 600 V or Peak
Max 840 V
Ω/ / /
Voltage and
Current input
prohibited
Hz / %
DCAC 600.0 V
mA
DCAC 600.0 mA
0.6 A / 600 V Fuse
Input
terminals
Maximum rating
input value
Maximum overload
protection input
1-3 Overload Protections
(Red)
(Black)
AC voltage is regulated by rms, value of sinusoidal wave.
1) Applications
The quality of diodes is tested.
2) How to use
ΩSet the FUNCTION switch to / / or .
Select by pressing the SELECT button.
Apply the red and black test pins to the object to be measured.
Conrm that a voltage drop is displayed in the forward direction test.
Conrm that ‘OL’ is displayed in the reverse direction test.
・ The input terminals open voltage is about 3.0 V
Note: If both and are conrmed, the diode is functioning normally.
1) Measurement procedure
Set the FUNCTION switch to Ω/ / or .
Apply the red and black test pins to the object to be measured.
Note :
If noise affects the measurement, shield the object being measured
with the COM potential. Additionally, if ngers come into contact
・
Resistance measurements cannot be performed on parts where
voltage is applied.
5-4 Testing Diode ( )
Never apply external voltage to the measurement terminals.
WARNING
1) Measurement procedure
Set the FUNCTION switch to “V” and use the SELECT button to choose
either DC or AC.
Apply the red and black test pins to the circuit to be measured.
The voltage reading will be displayed.
Fluctuations in the display when the test leads are disconnected are
normal and do not indicate a malfunction.
This device uses the True RMS method for AC wave detection, enabling it to
measure the root mean square values of both sine and non-sine waveforms.
(Accuracy is guaranteed for sine waves in the frequency range of 40 Hz to 400 Hz.)
In the 6.000 V AC range, a residual reading of approximately 3 to 9
counts may remain when the input is 0.
In the 600.0 V AC/DC range, whether set to auto or manual, an alarm
buzzer will sound if the measured value exceeds 600.0 V.
5-3 Resistance (Ω) Measurement
Never apply external voltage to the input terminals.
WARNING
5 MEASUREMENT PROCEDURE
1.
Never apply an input signal exceeding the maximum rating input value
of each function.
2. Do not turn the FUNCTION switch during measurement.
3.
Always keep your ngers behind the nger guards on the probe during
measurement.
4.
After measurement, release the test leads from the object measured
and set the FUNCTION switch to the OFF position.
WARNING
5-1 Start-up Inspection
1.
When the POWER switch is turned ON, conrm that the low battery warning
is not blinking or lit on the display. If it is, replace the battery with a new one.
2.
Do not use the device if the main body or test leads are damaged or broken.
3. Make sure that the test leads and fuse are not disconnected or blown.
WARNING
Note: If the display shows nothing, the battery may be completely drained.
START
Not damaged
Damaged
Main unit
and test leads
damaged?
The buzzer
sounds?
Yes
No
②Short the red and
black test pins.
Stop using it and have
it repaired.
Set the function at
" "
.
Check continuty of test
leads.
No problem.
Start measurement.
5-2 Voltage (V) Measurement
In the case of action or cancel that function as follows, do not turn the
FUNCTION switch in the condition applied input.
WARNING
4 DESCRIPTION OF FUNCTIONS
4-1 FUNCTION Switch
Turn this switch, to turn on and off the power and to select the functions of
Ω
/ / / ,  
Hz/%, mA
,EF
(EFisavailableonlywiththeCD800a3).
4-2 SELECT Button: Measurement Function Selection
When the SEL ECT but nto is pressed (), the n ofu cti ns change as f ws.ollo
In the case of V, mA, the modes change
In the case of
In the case of Hz %, the modes change Hz % Hz
Ω, , , e, the modes chang Ω→ →Ω
4-3 RANGE (Range Hold) Button
Press the RANGE button to switch to manual range mode, xing the range (‘AUTO’
will disappear, and ‘RANGE’ will light up on the display). In manual mode, each
press of the button changes the range. Select the appropriate range while checking
the unit and decimal point position on the display. To return to auto range mode,
press and hold the button for at least 1 second (‘AUTO’ will light up on the display).
Note: The RANGE button is disabled during , %, , , , and EF functions.Hz
4-4
REL (Relative) Button: Relative Value Display
When the REL button is pressed, ‘ ’ is displayed, and the value at that
point is set as Y. From then on, the value X-Y will be displayed based on
the actual input value X. To exit this mode, press the REL button again.
Note: The REL button is disabled during , %, , , , and MAX/MIN Hz EF
functions.
4-5 HOLD (Data Hold) Button
Pressing the HOLD button freezes the current displayed value (‘DH’ will
appear on the display). While active, the display remains unchanged even if
the input uctuates. Press the button again to deactivate the hold function
and return to measurement mode (‘DH’ will disappear from the display).
Note: The HOLD button is disabled during
EF
functions.
4-6 Backlight (CD800a3 only)
When the SELECT button is held pressed for 2 seconds or longer, the backlight will
be turned on. To turn it off, hold this button pressed for 2 seconds or longer again.
4-7 MAX/MIN Button
When the MAX/MIN button is pressed, 'MAX' appears on the display, and the
maximum measurement value recorded after pressing the button will be shown.
Note: The MAX/MIN button is enabled only during V and mA measurements.
Each time the button is pressed, the display will switch in the following order:
MAX (maximum measurement value)
→
MIN (minimum measurement value)
→
MAX-MIN. To cancel this function and reset the measurement value,
press and hold the MAX/MIN button or press the SELECT or RANGE button.
4-8 Auto Power Off
When no switch or button is operated for approximately 30 minutes after the power
is turned on, the power will automatically turn off, and all displays will disappear.
4-9 Buzzer Cancellation Function
To disable the buzzer, turn the FUNCTION switch to the ON position
while keeping the REL button depressed. The display will show ‘dbEP’
for 2 seconds, and the buzzer will be silenced (except for the alarm that
sounds when the V or mA measurement exceeds 600 V or 600 mA). To
restore this function, turn the FUNCTION switch to the OFF position to
power off the device, and then turn it back to the ON position.
5-5 Checking Continuity ( )
Never apply external voltage to the measurement terminals.
WARNING
1) Applications
Checking the continuity of wiring and selecting wires.
2) How to use
ΩSet the FUNCTION switch to / / or .
Select by pressing the SELECT button.
Apply the red and black test pins to a circuit or conductor to be measured.
The continuity can be judged by whether the buzzer sounds or not.
・ Threshold : 39 to 60 Ωorless
5-6 Capacitance ( ) Measurement
Never apply external voltage to the measurement terminals.
WARNING
1. Discharge the capacitor before measurement.
2. This device uses a method that applies current to the capacitor being
measured, making it unsuitable for measuring electrolytic capacitors
with high leakage current due to signicant errors.
3.
The measurement time increases for capacitors with larger capacitance.
CAUTION
1) Measurement procedure
ΩSet the FUNCTION switch to / / or .
Use the SELECT button to choose nF.
Press the REL button to zero the display to 0.000 nF.△
Apply the red and black test pins to the capacitor to be measured.
・ The display reading may uctuate due to ambient noise or the stray
capacitance of the test leads.
5-7 Frequency (Hz) and Duty Cycle (%) Measurement
5-8 Current Measurement (mA)
1. Never apply voltage to the input terminals.
2. Be sure to make a series connection via load.
3. eBefore starting measurement, turn OFF the power switch of th
circ it pa ate th meas ri art an en co ne tesu to se r e u ng p , d th n ct the t
leads rmly.
WARNING
5-9 EF: Electric Field Detection (CD800a3 only)
1.
Verify the functionality of this device using a known power source
before conducting electric eld detection.
2. Exercise caution, as the object may not be entirely voltage-free; for
example, voltages below the detectable threshold may still be present.
WARNING
1) Measurement procedure
①Set the FUNCTION switch to mA and use the SELECT button to
 choose either DC or AC.
Connect the red and black test pins in series with the load in the
 circuit to be measured.
For DC mA measurements: Connect the black test pin to the negative
potential side of the circuit and the red test pin to the positive potential
side, ensuring they are in series with the load.
 The alarm buzzer will sound if the measured value exceeds 600 mA
 in either the auto range or manual range 600.0 mA AC/DC settings.
6 MAINTENANCE
1. The section is very important for safety. Read and understand the
following instruction fully and maintain your instrument properly.
2.
The instrument must be calibrated and inspected at least once a year
to maintain the safety and accuracy.
WARNING
6-1 Maintenance and inspection
1) Appearance
・ Is the appearance not damaged by falling?
2) Test leads
・ Is the cord of the test leads not damaged?
・ Is the core wire not exposed at any place of the test leads?
NoteIf any of the above conditions apply, do not use the instrument.
Send it for repair or replace it with a new one. Also refer to section
5-1 to ensure that the test leads are intact and not damaged.
Note
6-2 Calibration
The manufacturer may conduct the calibration and inspection. Fo r
more information, please contact the dealers.
6-3 Battery and Fuse Replacement
1.
If the rear case or the battery lid is removed with input applied to the
input terminals, you may get electrical shock. Before starting the work,
always make sure that no input is applied.
2.
Be sure to use a fuse of the specied rating or type. Never use a
substitute of the fuse or never make a short circuit of the fuse.
WARNING
When inserting the batteries, make sure that their polarities are aligned correctly.
CAUTION
Rearcase
Batterylid
Batterylidscrew
R6(UM-3)
Remove the battery lid screw with a screwdriver.
Take out the battery or fuse and replace it with a new one.
Attach the battery lid and x with the screw.
Fuse
0.6 600A / V
F0325-1
Fast-blowtype
φ6.3×32mm
Blowoutcapacity:10kA
±(2.2 %rdg5dgt)
直流電流
DCmA
DC Current
±(2.8 %rdg5dgt)
※トランスや大電流路など強磁界の発生している近く、また無線機など強電界の
発生している近くでは正常な測定ができない場合があります。
確度計算方法 /Accuracycalculation
例)直流電圧測定(DCmV)/For example…Measurement 600 mVDC Range.
表示値 /Display value : 100.0[mV]
レンジ確度 / レンジ /Accuracy : 600.0[mV] Range…±(0.7 %rdg+3dgt)
誤差 /Error : ±(100.0[mV]×0.7 %rdg+3dgt)=±1.0[mV]
計算式 /Calculation : 100.0[mV]±(100.0[mV]×0.7 %rdg+3dgt)
真値 / の範囲内。True value : ln a range of 099.0[mV] 101.0[mV]
※600.0[mV]レンジにおける3[dgt]とは、0.3[mV]に相当します。
*3[dgt] in the 600.0[mV]range correspond to 0.3[mV]
ここに掲載した製品の仕様や外観は改良等の理由により、予告なしに変更
ることが有りますのでご承知ください。
Specications and external appearance of the product described above may
be revised for modication without prior notice.
20 80 %
±(0.5 %rdg5dgt)
オートレンジのみ
Auto range only
※矩形波信号における確度
Accuracy in the case of rectangular Wave
5 Hz 1 kHz 3 Vp-p 60 Vp-p
60.00 mA
600.0 mA
60.00 mA
600.0 mA
0.01 mA
0.1 mA
0.01 mA
0.1 mA
0.1 Ω
0.001 V
入力抵抗:約2.8Ω
Input Impedance: Approx. 2.8 Ω
ヒューズ耐圧600V
Fuse voltage
resistance 600 V
入力抵抗:約2.8Ω
Input Impedance: Approx. 2.8 Ω
ヒューズ耐圧600V
Fuse voltage resistance 600 V
※正弦波交流おける確度確度保証周波数範囲40〜400Hz
※Accuracyinthecaceofsinewave40〜400Hz
Checking Continuity
発音39〜60Ω以下・開放電圧:DC約0.4V
Buzzer sounds at less than 39 60 Ωto
Open voltage:Approx.DC 0.4 V
開放電圧:約3V
Open voltage: Approx. DC 3 V
Testing Diode
交流電流
ACmA
AC Current
8-2 / Measurement Range and Accuracy測定範囲及び確度
確度保証範囲:温度23±5℃ 湿度:80%R.H.以下 結露のないこと
Accuracy assurance range : 23±5 &less than 80 % R.H. No Condensation
rdg(reading):読取値、dgt(digit):最終桁のカウント数
7-3SANWA Website
https://www.sanwa-meter.co.jp
E-mail: exp_sales@sanwa-meter.co.jp
8 SPECIFICATIONS
8-1 General Specification
Measuring method Σ
Display
Sampling rate
Over ranging indication
“OL” mark indication
Low battery indication
Environmental condition
Power supply
Auto power off
Dimension
48 mm
L
176 mm×
W
104 mm×
H
Storage temperature /
humidity range
-10 50 ℃〜 70 %R.H. max. No condensation.
(Excluding batteries)
Automatic selection( ” is indicated when negative
voltage is applied.)
Range selection
Polarity indication
Operating temperature
5 40 ℃〜 humidity range: Maximum 80 % RH for temperatures
up to 31 decreasing linearly to 50 % RH at 40
Auto and Manual ranges
(Manual range or Auto range only)
Below approx. 2.4 V mark indication
6-4 Storage
1.
The panel and the case are not resistant to volatile solvent and must not be
cleaned with thinner or alcohol. For cleaning, use dry, soft cloth and wipe it lightly.
2. The panel and the case are not resistant to heat. Do not place the
instrument near heat-generating devices (such as a soldering iron).
3. Do not store the instrument, in a place where it may be subjected
to vibration or from where it may fall.
4. For storing the instrument, avoid hot, cold or humid places or places
5.
When the instrument will not be used for an extended period, be sure to remove the batteries.
under direct sunlight or where condensation is anticipated.
CAUTION
7 AFTER-SALE SERVICE
7-1 Warranty and Provision
Sanwa offers comprehensive warranty services to its end-users and to its
product resellers. Under Sanwa's general warranty policy, each instrumen t
is warranted to be free from defects in workmanship or material under
normal use for the period of one (1) year from the date of purchase.
This warranty policy is valid within the country of purchase only, and applied
only to the product purchased from Sanwa authorized agent or distributor.
Sanwa reserves the right to inspect all warranty claims to determine the
extent to which the warranty policy shall apply. This warranty shall not appl y
to fuses, s batt or a pr udi po blessa eries, ny od ct or part s, which h bave een
subject to one of the following causes:
1.
A failure due to improper handling or use that deviates from the instruction manual.
2.
A failure due to inadequate repair or modication by people other than Sanwa
service personnel.
3. A failure due to causes not attributable to this product such as re,
ood and
other natural disaster.
4. Non-operation due to a discharged battery.
5. A failure or damage due to transportation, relocation or dropping after the purchase.
7-2 Repair
Customers are asked to provide the following information when requesting services:
1. Customer name, address, and contact information
2. Description of problem
3. Description of product conguration
4. Model Number
5. Product Serial Number
6. Proof of Date-of-Purchase
7. Where you purchased the product
Please contact Sanwa authorized agent / distributor / service provider, listed in
our website, in your country with above information. An instrument sent to Sanwa /
agent / distributor without those information will be returned to the customer.
Note:
3 NAMES OF COMPONENT UNITS
Main Unit
CAUTION
1.
Correct measurement may not be performed when using the instrument in
the ferromagnetic / intense electric eld such as places near a transformer,
a high-current circuit, and a radio.
2.
The instrument may malfunction or correct measurement may not be performed
when measuring special waveform such as that of the inverter circuit.
DIGITAL MULTIMETER
CD800a2
CD800a3
Dempa Bldg
.
, 4-4 Sotokanda 2-Chome
Chiyoda-ku, Tokyo, Japan
SELECT/
Backlight
button
MAX/MIN
button
Test probe(Red)
Test probe(Black)
Test pins
Finger guards
Body Cover
Display
SELECT
button
Range Hold
button
Relative
button
Data Hold
button
Range Hold
button
Relative
button
Data Hold
button
MAX/MIN
button
Display
POWER/FUNCTION switch
Removable test pin
covers
When not covered:
CAT. 600 V
When covered:
CAT. 600 V
Stopper
Test Leads
Hand strap Hand strap
Measurement Category (Overvoltage Category)
Overvoltage measurement classication (CAT. II):
Line on the primary side of equipment with power cord to be connected to
the receptacle.
Overvoltage measurement classication (CAT. IV):
Line from the service conductor to the distribution board.
When not covered
This instruction manual explains how to use your new digital multimeter
CD800a2/CD800a3 safely. Before use, please read this manual thoroughly. After
reading it, keep it together with the product for reference to it when necessary.
Using this product in ways not specied in this manual may damage its
protection function.
The instruction given under the heading of must be followed WARNING
to prevent accidental burn or electrical shock.
2-2 Features
・Complies with IEC61010-1 CAT. IV 600 V.
・Includes a durable body cover that protects the main unit and doubles as
a stand.
・Features a MAX/MIN measurement function.
・Display with backlight (CD800a3 only).
EF Electric Field検知機能CD800a3 のみ)
EF (Electric Field) detection function (CD800a3 only) :
約90V以の交流電や電界を
Detects AC voltages or electric elds of approx. 90 V or higher.
  /備考
Note:
・検周波数:50Hz/60Hz
Detection frequency: 50 Hz / 60 Hz
・検出アンテナ:本体左上  マーク部EF
Detection antenna: Top left of the main unit, EF mark
AC detection method TrueRMS
Approx.3 times/sec
6000 counts (Hz: 9999 counts)
Operating altitude <2000 m / Pollution degree
30 min. (Approx. 10 µA)
R06 2×
Mass gApprox. 360
Accessories
Instruction manual, strap
Test lead
Fuse
ATL501, CAT. 600 V
0.6 A / 600 V, fast-acting fuse, parts number: F0325-1
Power consumption
LVD
3.9 mW TYP (DCV measurement, approx. 1.3 mA
with backlight off)
IEC61010-1, IEC61010-2-030,
IEC61010-2-033 IEC61010-031, CAT. 600 V
EMC IEC61326
600.0 mV
6.000 V
60.00 V
600.0 V
6.000 V
60.00 V
600.0 V
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
60.00 nF
600.0 nF
6.000 μF
60.00 μF
600.0 μF
6.000 mF
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
±(0.7 %rdg 3dgt)
±(1.1 %rdg 3dgt)
直流電圧
DCV
DC Voltage
±(1.6 %rdg 9dgt)
±(1.6 %rdg 5dgt)
±(1.5 %rdg 5dgt)
±(1.2 %rdg 5dgt)
Ω
Resistance
±(2.0 %rdg 3dgt)
±(5.0 %rdg 10dgt)
±(0.5 %rdg 3dgt)
.
ファンクション&レンジ
Function&Range
確 分解能
AccuracyResolution
備
Remarks
±(4.0 %rdg 3dgt)
入力抵抗:約10 MΩ
Input Impedance: Approx. 10 MΩ
入力抵抗:約10MΩ
Input Impedance: Approx. 10 MΩ
※正弦波交流における確度確度保証周波数範囲
 40〜400Hz
※Accuracyinthecaceofsinewave40〜400Hz
交流電圧
ACV
AC Voltage
静電容量
Capacitance
開放電圧:DC約 0.5V
Open voltage : Approx.DC 0.5 V
※オートレンジのみ
Auto range only
REL機能後の確度 
・6.000nFレンジは測定値を表示しますが、
 確度保証はしておりません
AccuracyafterRELfunction:
・Measurementvaluedisplayedin6.000nF
 range,butaccuracynotguaranteed.
※オートレンジのみ
Auto range only
※正弦波交流における確度
Accuracy in the case of sine wave
1 Hz 1 kHz, 3 Vrms 250 Vrms
1 kHz 99.99 kHz, 3 Vrms 20 Vrms
0.10 %
0.1 mV
0.001 V
0.01 V
0.1 V
0.001 V
0.01 V
0.1 V
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
0.001 mF
0.001 Hz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
デューティー比
%
Duty Cycle
周波数
Hz
Frequency
mA
mA mA
(×)
(○)
Measurement
function
Measurement
function
Measurement
function
Max. rated input
Max. rated input
600.0 mA DC
600.0 mA AC
Two ranges: 60.00 mA and
600.0 mA AC/DC
Measurement range
Measurement range
Hz
Frequency: 1 Hz to 99.99 kHz (auto range)
Duty cycle: 20 % to 80 %
1) Measurement procedure
Set the FUNCTION switch to Hz/%.
Press the SELECT button to switch to either frequency measurement mode
or duty cycle measurement mode.
Apply the red and black test pins to the object to be measured.
Signals with only positive or negative potential, such as logic pulses, cannot
be measured in duty cycle (%) mode.
Power source
Load
Power source
Load
Power
source
Load
Hz
%
Sine wave signals (for frequency
measurement) or pulse signals
(for duty cycle measurement)
Capacitor
6 ranges: 60.00 nF to 6.000 mF
6.000 mF
Measurement range
Diode
Anode
Cathode
Forward
direction test
Reverse
direction test
Extension cord
Ω
Ω
6 ranges: 600.0 Ω to 60.00 MΩ60.00 MΩ
Measurement
function
Max. rated input Measurement range
V
4 ranges: 600.0 mV to 600.0 V
3 ranges: 6.000 V to 600.0 V
600.0 V DC
600.0 V AC
Measurement
function
Max. rated input Measurement range
Even after the power is automatically turned off, a small amount of
power will still be consumed. Therefore, if the device will not be used for
an extended period, set the FUNCTION switch back to the OFF position.
To disable this function, press and hold the SELECT button while turning
the FUNCTION switch to the ON position. The display will show ‘dAPo’
for 2 seconds, and the clock icon will turn off.
with the test pins during measurement, errors may occur due to
the inuence of body resistance. The open voltage between the
input terminals is approximately 0.5 V.
1) Detection objective
To determine the presence or absence of voltage in AC voltage wiring.
2) Detection range
Sine wave AC voltage of 90 V or higher, at 50/60 Hz.
3) How to use this function
Bring the mark located at the upper-left corner of the device EF
close to or in contact with the target object for detection.
When voltage is detected, a “-” symbol will be displayed, and the buzzer will
sound on the ungrounded (hot) side.
The higher the detected voltage, the more ” symbols appear on the display
(up to 4), and the buzzer’s intermittent beeping will increase.
Notes:
In cases where the wiring is long, detection may also occur on the grounded side.
Depending on ambient conditions, the device may activate even when the
EF mark is not brought close to the target object.
Check
Battery
Outlet
DCV measurement
ACV measurement
Switched with
SELECT button
,
V
Resistor
Battery life
Approx. 650 hours at DCV
EF antenna
CD800a2 CD800a3
mA
mA
9 8 10 11
15 14 13 12
7
6 5 4
1 2 3


Produktspezifikationen

Marke: Sanwa
Kategorie: Multimeter
Modell: CD800a3

Brauchst du Hilfe?

Wenn Sie Hilfe mit Sanwa CD800a3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten