Lies die bedienungsanleitung für Solight DAC-9000 (11 Seiten) kostenlos online; sie gehört zur Kategorie Klimaanlage. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 2 Bewertungen. Hast du eine Frage zu Solight DAC-9000 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/11

Dear customer, thank you for purchasing our product. Please read the following instructions carefully and follow them to serve you safely
and to your full satisfaction. This will prevent misuse or damage. Avoid unprofessional handling of this appliance and always observe the
electrical appliance usage guidelines. Keep the instruction manual carefully. For use in the home or indoors .
DESCRIPTION OF EQUIPMENT
1. Control panel
2. Air outlet
3. Wheels
4. Air inlet
5. Filter
6. Connecting material
7. Air inlet
8. Handle
9. Storage space for plug
10. Power cord cover
11. Drain hole
12. Power cable
13. Drain cover and plug
14. Remote control
15. Connector
16. Exhaust hose
17. Adapter
EN DAC- 0900
Portable air conditioning
Flammable material!
This appliance contains flammable
R290/Propane refrigerant.

SAFETY NOTICE
• Do not use maintenance products other than those recommended by the manufacturer.
• The equipment must be stored in a room with no permanent sources of ignition (for example: an open flame, a working gas
appliance or a working electric heater).
• The equipment must be installed, operated and stored in a room with a floor area greater than 7 m2.
• Keep all necessary ventilation openings unobstructed.
• Do not modify, repair or disassemble the equipment. Service may only be performed by the manufacturer's service department.
• The equipment must be stored in a well-ventilated area the size of which corresponds to the area of the room to be used.
• The device is intended for indoor use only.
• When installing the air conditioner, follow the local rules for connecting it to the mains and ensure that it is properly earthed.
• Place the device in a flat and dry place and keep a distance of over 50 cm between the device and surrounding objects or walls.
• After installing the air conditioner, make sure the plug is intact and firmly inserted into the socket. Place the power cord neatly to
prevent someone from tripping or pulling the plug.
• Do not insert any objects into the air inlet and outlet of the air conditioner. Keep the air inlet and outlet free of obstructions.
• When installing the drainage pipes, make sure they are connected correctly and are not warped or bent.
• Equipment should be located away from gasoline, flammable gas, stoves and other heat sources.
• Do not install or use the device in a bathroom or other damp environment.
• Do not switch off the device by pulling the plug out of the socket.
• Do not place containers of liquids on the body of the unit to prevent water or other liquids from spilling into the air conditioner.
• Do not use insecticidal sprays or other flammable substances near the equipment.
• Do not wipe or wash the device with chemical solvents such as gasoline and alcohol. If you need to clean the air conditioner, you
must disconnect the power and clean it with a half-moistened soft cloth .
• Do not use the device if the power cord is damaged.
• The appliance must be installed in accordance with the regulations for the installation of electrical equipment .
PARAMETERS
Parameters
Model
DAC- 9000
Functions
Cooling, dehumidification, fan
Cooling power
9000 BTU/h
Cooling power
2,5 kW
Temperature setting range
17 30- ℃
Power supply
220-240V/50Hz
Rated power input - cooling
960 W
Rated current - cooling
4,3 A
EER for cooling
2,61
Refrigerant
R290/ 140 g
Number of fan speeds
2
Air circulation (high/low level)
300/220 m³
Dehumidification
28l/den
Water tank capacity
0,7l
Equipment dimensions
340*694*300 mm
Packaging dimensions
403*861*335 mm
Suitable for premises
25m2 (60m3)
Noise
51/53 dB
Weight
19,5 kg
Weight with packaging
22,5 kg
Controls
Smart Life/Tuya app + remote control
Window mounting kit
Universal

CONTROL PANEL
CONTROL DESCRIPTION
A. ON/OFF. POWER BUTTON
Switching the device ON and OFF
NOTE: Switch off the appliance by pressing the power button. Do not turn off the appliance by disconnecting the appliance from the
mains while it is running.
B. MODE BUTTON
Press the MODE button to toggle between operating options. The corresponding indicator will light up:
- - Cools the room to the set temperature Cool
- - Reduces the humidity in the room Dry
- - Circulates air in the room without coolingFan
C. SELECTION BUTTONS
⋀
⋀
⋀
⋀⋀ / ⋁
⋁
⋁
⋁⋁
Adjusts the values in the temperature or clock settings.
Temperature setting:
The temperature can be set between 17°C and 30°C when the air conditioner is in Cool mode.
1. Press the Mode button until the Cool mode light comes on
2. Press the Up or Down arrow button to select the mode.
Temperature:
The temperature cannot be set when the air conditioner is in Fan or Dehumidify mode.
Simultaneously pressing the Up Arrow and Down Arrow buttons allows you to choose between displaying th . e temperature in °C or °F
ICON
FUNCTION
ICON
FUNCTION
ICON
FUNCTION
ON/OFF.
BUTTON
(A)
MODE BUTTON
(B)
SELECTION BUTTON UP
(C)
TIMER
BUTTON
(D)
SPEED BUTTON
(E)
SELECTION BUTTON
DOWN (C)
TIMER INDICATOR
FAN INDICATOR
(HIGH)
WIFI INDICATOR
WATER INDICATOR
FAN INDICATOR
(LOW)
SLEEP MODE
INDICATOR
SLEEP MODE
INDICATOR
FAN INDICATOR
CONTROL PANEL
DISPLAY (D)
FAN INDICATOR
(COOLING)
D
C
C
E
B
A
Sleep
Produktspezifikationen
Marke: | Solight |
Kategorie: | Klimaanlage |
Modell: | DAC-9000 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Solight DAC-9000 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Klimaanlage Solight
9 Juli 2025
9 Juli 2025
Bedienungsanleitung Klimaanlage
- Carrier
- Kunft
- MundoClima
- Riffel
- Becken
- Airview
- Simplicity
- Bomann
- Braemar
- Fral
- Mesko
- Emmeti
- Ariston
- Xiaomi
- Argoclima
Neueste Bedienungsanleitung für -Kategorien-
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
10 Juli 2025
9 Juli 2025
9 Juli 2025