ProductDescription
TheP6316digitalprobeconnectstheTektronixMSO2000
Seriesofmixed-signaloscilloscopestodigitalbusesandsignals
onyourtargetsystem.Theprobebreaksout16datachannels
overtwo2x8-pinheaders(GROUP1andGROUP2).Each
headerincludeseightsignalsononerowandeightgrounds
alongtheoppositerow.
Apairofinterchangableflyingleadsetsareincludedwiththe
noneach
endandeightsignalleadsforconnectingtoindividualtest
points.
ConnectingtheProbetotheOscilloscope
Connecttheprobeasshownintheillustrationbelow.
1.Inserttheprobelabel-sideupintothereceptacle.
2.Toremovetheprobe,squeezethebuttonsonthesideand
pullouttheprobe.
ConnectingtheProbetoYourCircuit
Attachtheprobetothecircuitusingtheconnectorsandadapters
shownonthebackoftheseinstructions.Selectthebestmethod
foryourneeds,andthenproceedtoSettinguptheProbe.
SettinguptheProbe
PresstheD15-D0buttontosetandviewthefollowing
parametersofeachdigitalchannel:
Thresholdvoltageandverticalposition
Signalheight(setonceforall16channels)
Channellabel
Thedefaultsettingsare1.4Vthresholdswithnochannellabels.
UsetheB1andB2buttonstosetandviewbuscharacteristics
suchas:
Clocktype
Bustype(SerialorParallel)
Buswidth
Displayformat(Hex,Binary,ASCII)
ParallelbussetupinformationisresidentontheMSOFamily
ofoscilloscopes.However,forotherbusessuchasCANand
I2C,youmusthavetheappropriateapplicationkey.Seeyour
oscilloscopemanualorproductdatasheetfornomenclature
andorderingdetails.
FunctionalCheck
Logicactivityimmediatelydisplaysonallconnected,active
channels.Ifyoudonotseeanactivesignal:
1.PressTrigger.
2.SelectEdgefortriggertype.
3.Selectthechannelthatyouaresettingupasthesource.
4.PressAut
oset.
Ifyoudonotseeanactivesignal,tryanotherprobechannel(or
analogprobe)toverifycircuitactivityatthetestpoint.
Specifications
Table1:Electricalandmechanicalspecifications
CharacteristicDescription
Inputchannels16
Thresholdvoltagerange±20V
Thresholdaccuracy
±100mV+3%ofthresholdsetting
Minimu
msignalswing
500mVp
-p
Maximumsignalswing±20Vcenteredaroundthe
thresholdvoltage
Maximumnondestructive
inputsignaltoprobe
±40Vp-p
Inputresistance
101kΩ
Inputcapacitance8.0pF
Minimumdetectableinput
pulse
5ns
Probelength
0.9m(3ft)
Table2:Environmentalspecifications
CharacteristicsDescription
Temperature
Maximumoperating
Minimumoperating
Nonoperating
+50°C(+122°F)
0°C(+32°F)
–40°Cto+71°C
(–40°Fto+160°F)
Humidity
5%to95%relativehumidityatup
to+30°C(+86°F)
5%to60%RHabove+30°C
(+86
°F)upto+50°C(+122°F),
non-condensing
Altitude
Oper
ating
Nonoperating
3km(9,843ft)maximum
12km
(39,370ft)maximum
ElectrostaticImmunityTheprobeisnotstaticsensitive
EquipmentRecycling.Thisproductcomplies
withtheEuropeanUnion’srequirementsaccording
toDirective2002/96/EConwasteelectrical
and
electronicequipment(WEEE).Formore
informationaboutrecyclingoptions,checkthe
Support/ServicesectionoftheTektronixWebsite
(www.tektronix.com).
SafetySummary
ConnectandDisconnectProperly.Connecttheprobeoutput
tothemeasurementinstrumentbeforeconnectingtheprobe
tothecircuitundertest.Disconnecttheprobeinputandthe
probegroundfromthecircuitundertestbeforedisconnecting
theprobefromthemeasurementinstrument.
ObserveAllTerminalRatings.Toavoidfireorshockhazard,
observeallratingsandmarkingsontheproduct.Consultthe
productmanualforfurtherratingsinformationbeforemaking
connectionstotheproduct.
DonotOperateWithoutCovers.Donottouchexposed
connectionsandcomponentswhenpowerispresent.
AvoidExposedCircuitry.Donottouchexposedconnections
andcomponentswhenpowerispresent.
DoNotOperateWithSuspectedFailures.Ifyoususpectthereis
damagetothisproduct,haveitinspectedbyqualifiedservice
personnel.
DoNotOperateinWet/DampConditions.DoNotOperateinan
ExplosiveAtmosphere.
KeepProductSurfacesCleanandDry.
SafetyTermsandSymbolsTermsinThisManual.
Thesetermsmayappearinthismanual:
WARNING.Warningstatementsidentifyconditionsor
practicesthatcouldresultininjuryorlossoflife.
CAUTION.Cautionstatementsidentifyconditionsor
practicesthatcouldresultindamagetothisproductor
otherproperty.
SymbolsontheProduct.Thesesymbolsmayappearonthe
product:
TypicalApplication
1.UsetheP6316probetoviewdigitalsignalsonasystem
bus.
2.Useanalogprobes,suchastheP6139AorP2221probes
toviewanalogwaveforminformation.
P6316
DigitalProbe
Instruct
ions
x
1
*P0712
34500*
071-2345-00

Bewerten Sie dieses Handbuch


Produktspezifikationen

Marke: Tektronix
Kategorie: Nicht kategorisiert
Modell: P6316

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tektronix P6316 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten