Valcom V-2001A Bedienungsanleitung
Valcom
Türsprechanlage
V-2001A
Lies die bedienungsanleitung für Valcom V-2001A (5 Seiten) kostenlos online; sie gehört zur Kategorie Türsprechanlage. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Valcom V-2001A oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/5

VSP V E- - -2001A
Issue 4
1 947218
V E- -2001A
SINGLE ZONE (PLUS) PAGE CONTROL UNIT
INTRODUCTION
The V- -2001A E Page Control Unit is manufactured by
Valcom, Inc.
The V- -2001A E provides telephone system access to
a single zone of one-way paging.
"WARNING: To reduce the risk of fire or
electric shock, do not expose this equipment
to rain or moisture."
"WARNING: Shock Hazard - Do Not Open."
"AVIS: Risque de Choc Electrique ne pas
Ouvrir."
"PELIGRO: Corriente Electrica - No Abra."
“CAUTION: To reduce the risk of fire replace
only with same type 1A, 125V fuse. 1A, 125V
may be replaced by a 0.5A, 250V provided
voltage selector is set for 230V.”
“DANGER: Afin de réduire le risque de feu,
remplacez le fusible par le même type de
fusible à 1A, 125V. On peut utiliser un fusible
à 0.5A, 250V pourvu que le sélecteur
dalimentation soit fixé sur 230V. Ne pas
ouvrir.”
“VORSICHT: Zur verringerung von
feuergefahr die sicherung nur mit derselben
type 1A, 125V ersetzen. Statt 1A, 125V Kann
0.5A, 250V Benutzt werden, vorausgesetzt, die
spannung ist auf 230V eingestellt. Nicht
öffnen.”
“PELIGRO: Para reducir el peligro de
incendio remplazarlo unicamente con un
fusible del mismo tipo 1A, 125V. El fusible de
1A, 125V podra ser remplazado por uno de
0.5A, 250V si el selector de voltaje esta puesto
en 230V. No abres.”
SPECIFICATIONS
Access Methods
• Electronic Key System (C. O. Line Position)
• PABX (Loop or Earth Call Trunk Port)
1A2 Key Systems (400 type line card required)
• 600 Ohm Page Port
• Stand Alone Handset(s) (Used for access of the
V- -2001A E only)
Features
• Page override capability (Using C. O. line
position or loop start trunk port)
• Switchable battery feed for loop start operation
• RJ11 for "A" and "B" connections
• AGC on all voice outputs
• Provides audio for up to 150 Valcom one-way
amplified speaker assemblies
• Background music input
• Voice operated VOX to mute music during page
• Optional contact closure activation
• Easily accessible music and tone volume controls
• Removable screw terminal connectors provided
• Supplies 20 Valcom power units
(1 Amp -24VDC) for powering speaker amplifier
assemblies
• Page with music outputs (2 provided) music
mutes during page
• Page without music output
• Time clock/single tone (Contact closure
activated)

2
• Night ring/warble tone
(Closure or 90VAC activated)
Priority sequence of tones:
Page overrides music
Night ring mixes with music and page
Time clock mixes with music and page
• Individual switches for selection of night ring
and time clock tones per output
• May be used with 25 or 70 Volt amplifiers
• AC powered, 230 or 115VAC
• Internationally recognized power connector
• AC input fused at 0.5 Amp @ 230VAC, 50 Hz or 1
Amp @ 115VAC, 60 Hz
• 115/230 Volt selector switch for international use
• UL listed
Dimensions/Weight
• 7.10" H x 9.00" W x 2.40" D
(18.03cm H x 22.86cm W x 6.10cm D)
• 3.7 lbs. (1.68kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm nominal
Voice Switch Sensitivity: -21dBm
Music Source Input Impedance: 8 to 600 Ohms
Music Input Level: -10dBm nominal
Output Impedance: 8 Ohms
Output Level: -10dBm nominal
DC Output: 1 Amp at -24VDC
Nominal Power Requirements
Voltage: Current:
230VAC 0.5 Amp
115VAC 1 Amp
The V- - -2001A E is equipped with a standard 3 prong
polarized MOLEX connector to allow connection of a
battery backup supply in case of AC power failure.
• Use a cord set consis ting of a minimum 18 AWG
cord and grounding type attachment plug rated a
minimum of 15A, 250V. The cord set should have
the appropriate safety approvals for the country
in which the equipment will be installed and
should be marked HAR.
• The socket outlet shall be installed near the
equipment and shall be easily accessible.
Environment
Temperature: 0 to 40 Degrees C
Humidity: 0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in this
manual is the customer premise equipment such
as an electronic key system, a PABX or a
dedicated single line telephone set(s). The
V- -2001A E is not intended for direct or indirect
connection to the public telephone network or to
PABX analog station ports. When used with a
customer premise telephone system such as a
key system or PABX system, these units are
interfaced to the system via a fully protected page
port or system central office port, which is a fully
protected interface device. Also, the host system
must be configured to disallow central office
trunk conferencing in order to prevent indirect
connection to the public network.
Precautionary Designations
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Mounting
The V- -2001A E was designed for wall or table
mounting. Secure unit to wall studs or a suitable
brace away from heat sources or strong magnetic
fields (Motors, fans, power supplies, etc.) with the
control and terminal strip accessible. Four wood
screws are included for mounting.

3
Power Connections
NOTE: This equipment must be installed near an
AC power outlet due to the power cord being used
as a disconnect device.
The V- -2001A E may be used with one of the
following:
- - NEMA 5 15 cordset for North American use;
- CEE/7 cordset for Continental European use;
- BS1363 cordset for United Kingdom use.
- Connect cordset to unit via IEC 320 female connector
located on one end of the cordset to IEC 320 male
appliance coupler located on the V- -2001A E.
- For 115VAC use, verify fuse rating of 1 Amp and
voltage selector switch displays 115V.
- For 230VAC use, verify fuse rating of 0.5 Amp and
voltage selector switch displays 230V.
- After all required connections have been made, plug
the cordset into appropriate AC wall outlet.
J3
J2
SW4 SW2 SW1
R2
R40
ON
OFF
MUSIC
VOL.
TONES
VOL.
J1
J8
BATT.
FEED
A/TIP AND
B/RING PAGE
A/TIP
AND
B/RING
OVR
PAGE B/RING
PAGE A/TIP
MUSIC
CLOCK/STEADY TONE
UNA/WARBLE TONE
PC
-24V
GND
-24V
GND
PAGE W/
MUSIC
PAGE W/
MUSIC
INPUTS
OUTPUTS
A/TIP
B/RING
OR
Optional Background
Music Source
NOTE: Battery Feed Switch
ON - E-Key or PABX Loop
Start Trunk Port Access
OFF - Page Port Access
V-2001A-E
CAUTION: VORSICHT:
DANGER:
PELIGRO:
FIGURE 1: V-2001A-E CONNECTORS, CONTROLS, MOUNTING ORIENTATION AND ACCESS CONNECTIONS
UNA RINGING
PAGE w/o
MUSIC
GND
-24V
PPCC
Optional contact
operation when VOX
operation is not desired
CONTACT
CLOSURE
ACTIVATION
VACANT
C.O.PORT
OR
PAGE
PORT
TONES
ON
OFF
ON
OFF
SW2, SW4
ON = ENABLE
OFF = DISABLE
CONNECTIONS
Refer to Figure 1.
Electronic Key or PABX Access
When using the V- -2001A E with an electronic key
system C. O. line position or PABX trunk port, the
battery feed switch (SW1) must be ON.
Operation: Press line key (Electronic key system)
or dial trunk access code (PABX) to connect to the
paging speakers. Make announcement. The
V- -2001A E automatically disconnects from page.
Page Port Access
When accessing the V- -2001A E from a telephone
system page port, the battery feed switch (SW1) must
be OFF.
Operation: Follow the telephone system
manufacturer's instructions for access to external
paging. Make announcement. The V- -2001A E
automatically disconnects from page.
The V- -2001A E voice switching circuit is activated
when the person making the page begins to speak.
When the page is completed or the person stops
Produktspezifikationen
Marke: | Valcom |
Kategorie: | Türsprechanlage |
Modell: | V-2001A |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Valcom V-2001A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Türsprechanlage Valcom
29 Juni 2025
29 Juni 2025
28 Juni 2025
Bedienungsanleitung Türsprechanlage
- ZKTeco
- Caliber
- Hikvision
- Gewiss
- Leviton
- Philips
- Somfy
- BTicino
- Fanvil
- Chacon
- Mobotix
- EMOS
- Extel
- Tador