Lies die bedienungsanleitung für Elektrobock PT14 (4 Seiten) kostenlos online; sie gehört zur Kategorie Thermostat. Dieses Handbuch wurde von 11 Personen als hilfreich bewertet und erhielt im Schnitt 3.8 Sterne aus 6 Bewertungen. Hast du eine Frage zu Elektrobock PT14 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/4

• direct heaters
• rediant panels
• electric fl oor heating
Intended for:

INSTALLATION AND LOCATION
Install the thermostat at a suitable place where its operation cannot be affected by direct fl ow
of hot air from the heater, sunshine or other disturbing effects. Neither install it on an external
wall. The installation height should be approx. 1.5 m above the fl oor. Place the thermostat in
the “reference room”, such as the living room (the heating source will switch according to the
temperature in this room).
The installation must only be done by a properly qualifi ed person!
Before installation, disconnect the power supply!
1) Switch off the main circuit breaker.
2) Loosen the locking screw and remove the front part of the thermostat with the
electronics (Fig. 1).
3) Fix the back part of the thermostat to the wall (Fig. 2).
4) Connect conductors to the terminals acc. to the wiring diagram below, see Fig. 3.
5) Put on the front part of the thermostat with LCD and ensure the thermostat with the
locking screw against splitting.
6) Switch on the main circuit breaker. If everything is OK, the LCD shows the current
temperature.
INSTALLATION PROCEDURE
DESCRIPTION OF THE FUNCTION
The LCD backlight is activated by the fi rst pressing of
or button! Next pressing of this buttons change
the required temperature. Thermostat allows to set-up
temperature in range 3 °C to 39°C.
This temperature can be change by pressing of
and buttons or you can switch between two
temperature levels by pressing / buttons.
For you can set up e.g. 19°C, for e.g. 23°C.
Then you can only in the morning set and in the
evening .
If power failure occurs, then after its restoration is ther-
mostat set on mode on 18°C.
The factory-set is:
18°C
21°C
Theese values are always set up after power failure.
indication of heating
switched ON
Push-button for
temperature
damp
Temperature
mode switch
/
Push-button for
temperature
increase

Fig.1 Loosen the locking screw and remove
the thermostat electronics.
Fig.2 Fix the back part of the thermostat
to the wall.
Fig.3 Connect the inlet wires according
to the diagram.
Fig.4 Put the electronics part onto the bottom
part and ensure it with the locking screw.
L
N
HEATING
max. 16 A
UNUSED
holes for installation screws
Produktspezifikationen
Marke: | Elektrobock |
Kategorie: | Thermostat |
Modell: | PT14 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Elektrobock PT14 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostat Elektrobock
1 September 2024
26 August 2024
26 August 2024
20 August 2024
17 August 2024
12 August 2024
6 August 2024
5 August 2024
4 August 2024
1 August 2024
Bedienungsanleitung Thermostat
- Danfoss
- Amfra
- Sinustec
- Eberle
- HomeMatic
- Schneider
- Arnold Rak
- PECO
- SPC
- Technoline
- Xavax
- Orbis
- AWB
- Jumo
- Hive
Neueste Bedienungsanleitung für -Kategorien-
17 Juni 2025
16 Juni 2025
16 Juni 2025
15 Juni 2025
14 Juni 2025
14 Juni 2025
12 Juni 2025
12 Juni 2025
12 Juni 2025
8 Juni 2025