Lies die bedienungsanleitung für Hager CDF640T (2 Seiten) kostenlos online; sie gehört zur Kategorie Stromkreisunterbrecher. Dieses Handbuch wurde von 7 Personen als hilfreich bewertet und erhielt im Schnitt 4.8 Sterne aus 4 Bewertungen. Hast du eine Frage zu Hager CDF640T oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/2
Safety switch (RCCB's) 25 - 100 A
|
6LE003036Ad - 145822
OFF
green
z
For the tripping times verication tests, in an
electrical installation, Hager certies that the RCDs, of
the Hager brand, conforming to standards EN 61008-
2-1, EN 61009-2-1, trip under a current of 5*IΔn in
accordance with the times imposed in table 41.1 of
standard DIN VDE 0100-410 (VDE 0100-410) 2018-10.
Position contact indication.
Test
1, 3, 5...12
Fev.
Fev.
Jan.
Jan.
Test
OFF
yellow
or
Earth leakage fault indication.
Please note the following
1 - The current rating per pole of the RCCB must not be
exceeded by the maximum demand of the protected
circuits.
2 - If RCCB trips OFF after installation, locate and repair
faulty appliances (cumulative leakage from a number
of appliances may exceed the RCCB tripping
current, causing RCCB to trip OFF).
3 - The “main neutral” and “main earth” should be
checked to ensure good connection.
4 - If RCCB trips intermittently will not reset, or test
button will not work, check for low insulation
resistance between neutral & earth wiring.
5 - RCCB may be fed in any position:
LOAD and LINE circuits may be connected top or
bottom.
Electrical connection for P+N or for three phase only.
Three phase & neutral use
or Three phase use
Single phase use
Two circuits
L1
L1
T
2468
1357
N
N
N
N
7
/
1
 1
/
/
/
/
/ 1
1
1
 1
/1 1/
/1
1/
7
7
/
1
 1
/
/
/
/
/ 1
1
1
 1
/1 1/
/1
1/
7
One circuit
Electrical connection 2 pole.
For an RCD where two or three circuits are to be protected, the Hager neutral link KM03A
may be connected to the outgoing N terminal for the convenient splitting of the neutrals.
N1 N2 L2L1
2
13N
L
KM03A
RCD
Neutral
Link
Main
Neutral Link
4N
T
L1 - circuit
1
L2 - circuit
2
Safety instructions
The installation and mounting of electrical
appliances must only be performed by qualied
electricians, in compliance with installation
standards and in accordance with the guidelines,
provisions and safety and accident prevention
regulations in force in the country concerned.
14 mm max. 16 - 63 A 80 - 100
A
16
mm
2
35
mm
2
25
mm
2
50
mm
2
1 Hager Electro S.A.S., Boulevard d'Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com


Produktspezifikationen

Marke: Hager
Kategorie: Stromkreisunterbrecher
Modell: CDF640T

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager CDF640T benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Stromkreisunterbrecher Hager

Bedienungsanleitung Stromkreisunterbrecher

Neueste Bedienungsanleitung für -Kategorien-