Lies die bedienungsanleitung für Janitza CT27 (2 Seiten) kostenlos online; sie gehört zur Kategorie Nicht kategorisiert. Dieses Handbuch wurde von 2 Personen als hilfreich bewertet und erhielt im Schnitt 4.2 Sterne aus 5 Bewertungen. Hast du eine Frage zu Janitza CT27 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

Technical Specifications
Safety and environmental conditions
CE markingLV directive 2014/35/EU
RoHS directive (EU) 2015/863
StandardEN-IEC 61010-1:2010
WEEE directive 2012/19/EU
This product is designed to be safe under the following conditions:
LocationIndoor use
AltitudeUp to 2000m (1.24mi)
Ambient temperature-10°C to +55°C (14°F to 131°F)
Storage temperature-20°C to +70°C (-4°F to 158°F)
Relative humidity5% to 85%, non condensing
Pollution degree2
Degree of protectionIP20
The CT27 is only suitable for insulated primary conductors.
Specifications
StandardIEC 61869-2:2012
Rated short-time thermal
current (Ith)
60 x Ipr / 1s
Rated dynamic current (Idyn)2,5 x Ith
Continuous thermal current
(Icth)
100%
Rated insulation level0,72/3/- kV
Rated frequency50/60Hz
Class of insulationA (105 °C / 221 °F)
Secondary terminalFemale clamping connector,
suitable for conductor size:
0,2 to 1,5mm² solid, stranded
or ferruled (Strip length 8 to
9mm) (0.315 to 0.354in)
Specifications per type
CT27
Secondary
leads format*
0,5mm
2
max. 1,4m
(55in)
0,75mm
2
max. 2,0m
(79in)
1,0mm
2
max. 2,8m
(110in)
1,5mm
2
max. 4,0m
(157in)
Suitable for
cable
ø 7,5mm (0.295in)
Approximate
weight
40g (0.088lb)
* Maximum length secondary leads for 0,1VA at the end of this leads.
Janitza electronics GmbH reserves the right to carry out modifications on
its products, in order to improve them, without prior notice.
CT27 Current Transformer
Installation Guide
Janitza electronics GmbH
Vor dem Polstück 6
35633 Lahnau | Germany
Support +49 6441 9642-22
[email protected] | www.janitza.com
Doc. No. 2.002.160.1.a | Issue date 06/2022
Subject to technical alterration
Explanation of symbols
This product is designed according to the EN-IEC
61010-1:2010 standards and therefore this product
meets the requirements of the Low Voltage Directi-
ve 2014/35/EU.
Read the installation guide before mounting the
product. Unprofessional work activities on electrical
installations may result in a threat of danger to the
life and health of human beings and livestock!
Under no circumstances the secondary circuit of
the CT may be opened when the CT is mounted
on a primary current and current is flowing in the
primary circuit. High voltages may appear on the
secondary leads when this circuit is left open.
RoHS Directive (EU) 2015/863
Janitza electronics GmbH states that they only uses
qualified component in their products from ma-
nufacturers, whose specifications meet or exceed
the requirements of the European Directive for the
Restriction of use of certain Hazardous Substances.
WEEE Directive 2012/19/EU
The ‚crossed out wheeled bin‘ symbol indicates
that the equipment should not be disposed as un-
sorted municipal waste. Contact a qualified recycler
for disposal.
CT27-35
CT27-64
General
The CT27 is a current transformer and can only be used measuring
electrical alternating currents. The CT27 is suitable only for moun-
ting on insulated primary conductors in a weather protected and
dry location.
Read this installation guide before installing the product.
Produktspezifikationen
| Marke: | Janitza |
| Kategorie: | Nicht kategorisiert |
| Modell: | CT27 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Janitza CT27 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Nicht kategorisiert Janitza
31 Januar 2026
29 Januar 2026
28 Januar 2026
25 Januar 2026
22 Januar 2026
22 Januar 2026
24 Juli 2025
23 Juli 2025
23 Juli 2025
23 Juli 2025
Bedienungsanleitung Nicht kategorisiert
Neueste Bedienungsanleitung für -Kategorien-
31 Januar 2026
31 Januar 2026
31 Januar 2026
31 Januar 2026
31 Januar 2026
31 Januar 2026
31 Januar 2026
31 Januar 2026
31 Januar 2026
31 Januar 2026