Lies die bedienungsanleitung für Klein Tools CL445 (56 Seiten) kostenlos online; sie gehört zur Kategorie Messung. Dieses Handbuch wurde von 4 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 2.5 Bewertungen. Hast du eine Frage zu Klein Tools CL445 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage

Seite 1/56
INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 37
ESPAÑOL pg. 19
HVAC Clamp Meter
True RMS
Measurement
Technology
DC MICROAMPS
INRUSH CURRENT
NON-CONTACT
VOLTAGE TESTING
AUTO-RANGING
TEMPERATURE
AUDIBLE CONTINUITY
5001748
750V
600V
600A
60M
Ω
2m
-148° –
1832°F
-100° –
1000°C
CL445
CAT IV
600V
HVAC Clamp Meter
True RMS
Measurement
INRUSH CURRENT
VOLTAGE TESTING
AUDIBLE CONTINUITY
HVAC Clamp Meter
AUDIBLE CONTINUITY
2
GENERAL SPECIFICATIONS
Klein Tools CL445 is an automatically ranging true root mean
square (TRMS) digital clamp meter that measures AC current and
inrush via the clamp, AC/DC voltage, DC microamps, resistance,
continuity, frequency, capacitance, and tests diodes via test leads, and
temperature via a thermocouple probe.
Environment: Indoor. DO NOT expose to moisture, rain, or snow.
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: <95% non-condensing
Operating Temp: 32° to 122°F (0° to 50°C)
Storage Temp: 14° to 122°F (-10° to 50°C)
Accuracy: Values stated at 65° to 83°F (18° to 28°C)
Temp Coef cient: 0.1 × (Quoted Accuracy) per °C above 28°C
or below 18°C, corrections are required when ambient working
temp is outside of Accuracy Temp range
Dimensions: 9.24" × 3.77" × 1.59" (235 × 96 × 40 mm)
Weight: 12.58 oz (356.5 g) including batteries
Calibration: Accurate for one year
Auto Power-Off (APO): After approx. 10 minutes of inactivity
Standards: IEC/BS/EN 61010-1, 61010-2-032,
IEC/BS/EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1, 61010-2-032;
Certified to CSA STD.C22.2 NO. 61010-1,
61010-2-032.
Pollution degree: 2
Accuracy: ± (% of reading + # of least significant digits)
Safety Rating: CAT IV 600V
Class 2, Double insulation
Drop Protection: 6.6 ft. (2 m)
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s low-
voltage MAINS installation.
Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.