Lies die bedienungsanleitung für Sauermann Si-52 (2 Seiten) kostenlos online; sie gehört zur Kategorie Pumpe. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.6 Sterne aus 2 Bewertungen. Hast du eine Frage zu Sauermann Si-52 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/2

Si-52
Peristaltic pump
Sauermann
®
part #: SI52CE01UN23
This peristaltic pump is designed for all types of air conditioners up to 8 kW: wall
units, air conditioning cabinets, ceiling units and ducted units.
The Si-52 is controlled by its oat switch (3 levels: on, off, safety). The safety
contact automatically stops the air conditioner compressor or solenoid valve to
prevent condensate overow.
Not for continuous operation.
Kit content
• Peristaltic pump Si-52
• Cable: 1.7 m, including 2 wires for power
supply (P & N)
• 2 safety switch wires (1.7 m)
• Easy 2-screw sliding plastic bracket
• Detection unit (SI2958, 1.5 m cable)
• Detection unit installation kit:
- Vent tube int. Ø 4 x L 75 mm
- Mounting rail
- Adhesive
• 90° connector Ø 15 mm - 45 x 152 mm
DATA SHEET
Benets
High performance
• Condensate discharge up to 12 m high
• Quiet, vibration-free operation
Easy installation
• Compact size: L105 x W108 x H122 mm
• IP55 protection for installation in
unventilated areas
Extended reliability
• Thick, reinforced tube for longer service life
• Resistance to contaminated condensate
(particles and chemicals)
Quick maintenance
• Easy-to-open front panel without tools
for tube replacement
• Glass fuse replaceable in one easy step
(standard cartridge 5 x 20)

For use with any air-conditioning
units up to 8 kW
Technical specications
Applications
Actual ow rate (l/h)
sauermanngroup.com
SI52CE12UN23_EN - 12/06/2025 – Non-contractual document. We reserve the right to modify the characteristics on our products without prior notice.
Max. ow rate 6 l/h
Max suction head 2 m
Max discharge head 12 m
Sound level in application at 1m
(Measured in Sauermann acoustic lab,
pump operating with water)
≤ 30 dBA
Mains supply 230 V~ 50 Hz - 11 W
Insulation class
(double insulation)
Detection type Detection unit oat
Detection levels On: 16 mm; Off: 11 mm; Safety: 19 mm
Safety switch NF 8A resistive – 250 V
Protection IP55
Pump dimensions L 105 x W 108 x H 122 mm
Detection unit dimensions L 55 x W 38 x H 37.5 mm
Safety standards CE & UKCA
RoHS directive Compliant
WEEE directive Compliant
Packaging 1.04 kg
Masterpack 24 pieces
Total tube length (int. Ø 6 mm; 1/4’’)
Max suction
head
Max discharge
head
The discharge ow is constant whatever the discharge or the
suction head
2 m 12 m 6
Accessories
• Wall mounted
• Computer room air
conditioning
• Ceiling suspended
• Ducted
Name #Part
Clear PVC hose
int. Ø 6 mm (1/4’’)
ACC00909 (5 m)
ACC00910 (50 m)
Replacement head
for Si-50, Si-51, Si-52
ACC00954
Multi diameter
reducing adaptor
to connect tubes of
Ø 15 mm (3/5’’),
Ø 6 mm (1/4’’)
ACC00927
Replacement hose
for Si-50, Si-51, Si-52
ACC00953
6 self-sealing ttings
for hose int. Ø 6 mm
(1/4’’)
ACC00919
Detection unit 1.5 m
power cable
SI2958
Produktspezifikationen
Marke: | Sauermann |
Kategorie: | Pumpe |
Modell: | Si-52 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Sauermann Si-52 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Pumpe Sauermann
14 August 2025
14 August 2025
14 August 2025
14 August 2025
14 August 2025
13 August 2025
Bedienungsanleitung Pumpe
- Bartscher
- SHURflo
- Rule
- Gardenline
- Sthor
- Fluval
- Zodiac
- Powerplus
- Eheim
- Yamazen
- Velda
- Telestar
- Metabo
- Milwaukee
- Hozelock
Neueste Bedienungsanleitung für -Kategorien-
14 August 2025
14 August 2025
14 August 2025
13 August 2025
13 August 2025
8 August 2025
6 August 2025
5 August 2025
5 August 2025
5 August 2025