Klein Tools IR1 Bedienungsanleitung
Lies die bedienungsanleitung für Klein Tools IR1 (11 Seiten) kostenlos online; sie gehört zur Kategorie Thermometer. Dieses Handbuch wurde von 5 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 3 Bewertungen. Hast du eine Frage zu Klein Tools IR1 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/11

INSTRUCTION MANUAL
FRANÇAIS pg. 13
ESPAÑOL pg. 7
Infrared Thermometer
• TARGETING LASER
• 10:1 DISTANCE-
TO-SPOT RATIO
• BACKLIT DISPLAY
• AUTO POWER-OFF
ENGLISH
2m
IR1
-4° –
752°F
-20° –
400°C

2
GENERAL SPECIFICATIONS - IR1
Klein Tools IR1 is an entry-level infrared thermometer with targeting
laser. It offers a wide measurement range, a 10:1 distance–to-spot
ratio, a targeting laser, and user-selectable from Fahrenheit to Celsius
temperature scales.
• Environment: Indoor or outdoor
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <85% non-condensing
• Operating Temp: ° ° ° °32 to 122 F (0 to 50 C)
• Storage Temp: ° ° ° °-4 to 140 F (-20 to 60 C)
• Measurement Range: ° ° ° °-4 to 752 F (-20 to 400 C)
• Units: Settable to °F or °C
• Emissivity: 0.95 fixed
• Optical Resolution (Distance-to-spot): 10:1
• Dimensions: 6" x 4.1" x 1.7" (152 x 104 x 43 mm)
• Weight: 7.4 oz. (210 g) including battery
• Battery Type: 1 x 9V battery
• Battery Life: (Estimates assume 9V Zinc-Carbon Battery)
5 hours continuous use w/laser and backlight on.
• Display: Backlit LCD with white backlight
• Display Resolution: 0.1°F (0.1° C)
• Laser: FDA and IEC Class 2
• Wavelength: 630 – 670 nm
• Max Power: 1mW
• Beam Divergence: 1.5mrad
• Standards: Certified to IEC EN 61326-1:2013, EN 61326-2-3:2013,
IEC EN 60825-1:2014
Complies with 21 CFR 1040.10 and 1040.11 except for
conformance with IEC 60825-1 ED. 3, as described in
Laser Notice No. 56 dated May 8, 2019
• Pollution degree: 2
• Drop Protection: 6.6 ft. (2m)
Specifications subject to change.
ENGLISH
MEASUREMENT SPECIFICATIONS
• Response Time: <500ms
• Data hold: Yes
• Spectral Response: 8000-14000nm
≥32
°F
(≥0
°C
) ±4
°F
(±2
°C
) or ±2%, whichever is greater
<32
°F
(<0
°C
)
±(4
°F
+ 0.1
°F
per degree below 32
°F
)
±(2.0
°C
+ 0.1
°C
per degree below 0
°C
)
• Repeatability: ±1.0% of reading or ±2°F(±1°C)
(whichever is greater).
• Temperature Correction Coefcient:
±0.1°F per °F (±0.1°C per °C), or ±0.2%
of reading (whichever is greater) when ambient temperature is above or
below 70 – 77°F (21 – 25°C).
Specifications subject to change.

4
3
1
2
6
1.
LCD Display
2.
Trigger
3.
Battery Compartment Door
4.
IR Temperature Sensor
5.
Targeting Laser
6.
° °F/ C Switch (Behind
Battery Compartment Door)
NOTE: There are no
user-serviceable parts
inside meter.
FEATURE DETAILS
ENGLISH
A.
Temperature Reading
B.
Targeting laser active
C.
Data Hold
D.
Battery level indicator
E.
Active temperature scale
SYMBOLS ON LCD
4
5
Front
B DC
E
A
Produktspezifikationen
Marke: | Klein Tools |
Kategorie: | Thermometer |
Modell: | IR1 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Klein Tools IR1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermometer Klein Tools
2 September 2025
1 September 2025
1 September 2025
31 August 2025
30 August 2025
30 August 2025
29 August 2024
27 August 2024
28 Januar 2024
Bedienungsanleitung Thermometer
- AvaTemp
- Orbegozo
- Vicks
- Esperanza
- Laica
- Stanley
- Bioland
- General
- Citizen
- Comark
- IHealth
- Reer
- Clas Ohlson
- Clatronic
- Steinberg
Neueste Bedienungsanleitung für -Kategorien-
5 September 2025
2 September 2025
1 September 2025
31 August 2025
30 August 2025
29 August 2025
28 August 2025
28 August 2025
24 August 2025
24 August 2025