Klein Tools IR10 Bedienungsanleitung
Klein Tools
Thermometer
IR10
Lies die bedienungsanleitung für Klein Tools IR10 (32 Seiten) kostenlos online; sie gehört zur Kategorie Thermometer. Dieses Handbuch wurde von 20 Personen als hilfreich bewertet und erhielt im Schnitt 4.7 Sterne aus 10.5 Bewertungen. Hast du eine Frage zu Klein Tools IR10 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/32

IR10
FRANÇAIS p. 21
ESPAÑOL pg. 11
• DUAL-LASER
TARGETING
• 20:1 DISTANCE-
TO-SPOT RATIO
• ADJUSTABLE
EMISSIVITY
• K-TYPE PROBE
MEASUREMENTS
• AUTO-SCAN
• MAX/MIN/AVG/DIFF
• HIGH/LOW AUDIBLE &
VISUAL ALARMS
• BACKLIT DISPLAY
• AUTO POWER-OFF
ENGLISH
-40° – 1200° F
(-40° – 650° C)
INSTRUCTION MANUAL
Dual-laser Infrared
Thermometer
3
m IP54

2
GENERAL SPECIFICATIONS
Klein Tools IR10 is a professional dual-laser targeting infrared (IR)
thermometer. It offers a wide measurement range, a tight distance-
to-spot ratio, dual targeting lasers, and several calculation modes to
facilitate different temperature measurement applications. In addition
to measuring temperature using IR emission it can also measure
temperature using a standard K-type probe.
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <85% non-condensing
• Operating Temp: ° ° ° °32 to 122 F (0 to 50 C)
• Storage Temp: ° ° ° °-4 to 140 F (-20 to 60 C)
• Measurement Range: -40°F to 1200°F (-40°C to 650°C)
• Units: Settable to °F or °C
• Emissivity: 0.10-1.00 adjustable
• Optical Resolution (Distance-to-spot): 20:1
• Dimensions: 7" x 4.49" x 2.05" (178 x 114 x 52 mm)
• Weight: 9.1 oz. (256 g) including battery
• Battery Type: 1 x 9V battery
• Battery Life: (Estimates assume 9V alkaline battery)
8 hours continuous infrared measurement
w/laser and backlight on
• Display: Backlit LCD
• Display Resolution: 0.1°F (0.1° C)
• Calibration: Accurate for one year
• K-Type Probe: Included probe suitable for -40°F to 356°F
(-40°C to 180°C)
• Lasers: FDA and IEC Class II, <1mW each laser, 630-670nm
• Standards:
Conforms to IEC EN 61326-1:2013,EN608251:2014
Complies with: 21 CFR 1040.10 and 1040.11 except for
deviations pursuant to laser notice No. 50, dated June 24, 2007
• Pollution Degree: 2
• Ingress Protection: IP54 dust & water resistant
• Drop Protection: 9.8 ft. (3m)
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH

3
MEASUREMENT SPECIFICATIONS
Specication IR Measurement K-Type Measurement
Range -40°F to 1200°F
(-40°C to 650°C)
-40°F to 1200°F
(-40°C to 650°C)
Accuracy
≥32°F (0°C): ±3°F (±1.5°C)
or ± 1.5% whichever is
greater
<32°F (0°C):
±(3.6°F + 0.2°F per degree)
(±(2°C + 0.2°C per degree))
≥32°F (0°C): ±2°F (±1°C)
or ±1%, whichever is
greater
<32°F (0°C): ±3°F (±1.5°C)
or ±1%, whichever is
greater
Repeatability ±0.8% or ±2F(±1C),
whichever is greater
±0.5% or ±1F (±0.5C),
whichever is greater
Spectral
Response 8-14µm N/A
Response
Time <150ms <150ms
Data Hold Yes Yes
MAX/MIN/
Average/
Differential
Yes Yes
Measurement
out of range ‘----‘ on display ‘----‘ on display
Temperature
Correction
Coefcient
Temperature Correction Coefficient: ±0.2°F per °F
(±0.1°C per °C), or ±0.2% of reading (whichever
is greater) when ambient temperature is above or
below 70 – 77°F (21 – 25°C).
Specifications subject to change.
NOTE: The included K-type probe is suitable ONLY for
temperatures of -40°F to 356°F (-40°C to 180°C). For
temperatures above 356°F (180°C), a high-temp K-Type
probe is required.
Produktspezifikationen
Marke: | Klein Tools |
Kategorie: | Thermometer |
Modell: | IR10 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Klein Tools IR10 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermometer Klein Tools
29 August 2024
27 August 2024
28 Januar 2024
Bedienungsanleitung Thermometer
- Speco Technologies
- Optex
- Laica
- La Crosse
- TrueLife
- Delta Ohm
- Rossmax
- Technoline
- Citizen
- General
- ClimeMET
- Steinberg
- Beaba
- Sensitec
- IHealth
Neueste Bedienungsanleitung für -Kategorien-
16 Juni 2025
14 Juni 2025
14 Juni 2025
13 Juni 2025
13 Juni 2025
13 Juni 2025
12 Juni 2025
12 Juni 2025
9 Juni 2025
9 Juni 2025