Klein Tools IR1KIT Bedienungsanleitung
Klein Tools
Thermometer
IR1KIT
Lies die bedienungsanleitung für Klein Tools IR1KIT (13 Seiten) kostenlos online; sie gehört zur Kategorie Thermometer. Dieses Handbuch wurde von 3 Personen als hilfreich bewertet und erhielt im Schnitt 4.9 Sterne aus 2 Bewertungen. Hast du eine Frage zu Klein Tools IR1KIT oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/13

INSTRUCTION MANUAL
FRANÇAIS pg. 17
ESPAÑOL pg. 9
Infrared
Thermometer
(pg. 2)
GFCI Receptacle Tester
(pg. 7)
INSPECTION KIT
• TARGETING LASER
• 10:1 DISTANCE-
TO-SPOT RATIO
• BACKLIT DISPLAY
• AUTO POWER-OFF
• FOR STANDARD AND GFCI
RECEPTACLES
• DETECTS OPEN GROUND,
REVERSE POLARITY, OPEN
HOT, OPEN NEUTRAL,
HOT/GROUND REVERSED
ENGLISH
INSTRUCTION MANUAL
Thermometer
INSPECTION KIT
TARGETING LASER
10:1 DISTANCE-
TO-SPOT RATIO
BACKLIT DISPLAY
AUTO POWER-OFF
2m
IR1KIT
-4° –
752°F
-20° –
400°C
CAT II
300V
2m

2 3
GENERAL SPECIFICATIONS - IR1
Klein Tools IR1 is an entry-level infrared thermometer with targeting
laser. It offers a wide measurement range, a 10:1 distance–to-spot
ratio, a targeting laser, and user-selectable from Fahrenheit to Celsius
temperature scales.
• Environment: Indoor or outdoor
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <85% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: -4° to 140°F (-20° to 60°C)
• Measurement Range: -4° to 752°F (-20° to 400°C)
• Units: Settable to °F or °C
• Emissivity: 0.95 fixed
• Optical Resolution (Distance-to-spot): 10:1
• Dimensions: 6" x 4.1" x 1.7" (152 x 104 x 43 mm)
• Weight: 7.4 oz. (210 g) including battery
• Battery Type: 1 x 9V battery
• Battery Life: (Estimates assume 9V Zinc-Carbon Battery)
5 hours continuous use w/laser and backlight on.
• Display: Backlit LCD with white backlight
• Display Resolution: 0.1°F (0.1° C)
• Laser: FDA and IEC Class 2
• Wavelength: 630 – 670 nm
• Max Power: 1mW
• Beam Divergence: 1.5mrad
• Standards: Certified to IEC EN 61326-1:2013, EN 61326-2-3:2013,
IEC EN 60825-1:2014
Complies with 21 CFR 1040.10 and 1040.11 except for
conformance with IEC 60825-1 ED. 3, as described in
Laser Notice No. 56 dated May 8, 2019
• Pollution degree: 2
• Drop Protection: 6.6 ft. (2m)
Specifications subject to change.
ENGLISH
MEASUREMENT SPECIFICATIONS
• Response Time: <500ms
• Data hold: Yes
• Spectral Response: 8000-14000nm
≥32
°F
(≥0
°C
) ±4
°F
(±2
°C
) or ±2%, whichever is greater
<32
°F
(<0
°C
)
±(4
°F
+ 0.1
°F
per degree below 32
°F
)
±(2.0
°C
+ 0.1
°C
per degree below 0
°C
)
• Repeatability: ±1.0% of reading or ±2°F(±1°C)
(whichever is greater).
• Temperature Correction Coefcient:
±0.1°F per °F (±0.1°C per °C), or ±0.2%
of reading (whichever is greater) when ambient temperature is above or
below 70 – 77°F (21 – 25°C).
Specifications subject to change.
WARNINGS
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe
injury or death. Retain these instructions for future reference.
WARNING: LASER RADIATION. DO NOT STARE INTO BEAM.
Class II Laser.
• Exposing eyes to laser radiation can result in severe and permanent eye
injuries. NEVER look directly into the laser beam emitted by this instrument.
• DO NOT use the instrument if the case is damaged in any way.
• DO NOT modify the instrument in any way, as to do so could result in
emission of hazardous laser radiation than could result in severe and
permanent eye injuries.
• DO NOT use optical equipment such as lenses, prisms, optical scopes,
etc. to transmit, retransmit, or view the laser beam as this could result in
severe and permanent eye injuries.
• This product should not be used in any location that could result in
somebody looking at or having their eyes inadvertently irradiated by the
laser beam as this could result in severe and permanent eye injuries.
• This product should not be used by untrained operators or operators who
have not read and fully understood the instructions.
• Thermometer is NOT intended for use on people or animals.
• DO NOT remove warning labels from this instrument as this could result
in serious personal injury and increases the risk of exposure to hazardous
laser irradiation.
• Discontinue using the instrument immediately if it is acting abnormally.
• There are no user serviceable parts in this instrument.
CAUTION
• BURN HAZARD. Reflective materials may have a higher actual
temperature than the measured temperature.
SAFE PRACTICES
This meter is designed for professionals who understand the hazards
associated with their trade. While this meter causes no foreseeable
dangers beyond its targeting laser, the objects being measured, as
well as the environment in which they reside, can be hazardous.
Common safety practices to follow when operating near temperature
critical environments are:
• Before using this meter, determine if an area is safe, verify correct operation
by measuring a known temperature value of a comparable object.
Warning label on side of thermometer
Produktspezifikationen
Marke: | Klein Tools |
Kategorie: | Thermometer |
Modell: | IR1KIT |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Klein Tools IR1KIT benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermometer Klein Tools
2 September 2025
1 September 2025
1 September 2025
31 August 2025
30 August 2025
30 August 2025
29 August 2024
27 August 2024
28 Januar 2024
Bedienungsanleitung Thermometer
- Save Demp
- Elektrobock
- Turbotech
- Elro
- Medisana
- Jumper
- Weber
- Kyoritsu
- TFA
- Fysic
- SilverCrest
- Ecomed
- CDN
- Laserliner
- Emga
Neueste Bedienungsanleitung für -Kategorien-
5 September 2025
2 September 2025
1 September 2025
31 August 2025
30 August 2025
29 August 2025
28 August 2025
28 August 2025
24 August 2025
24 August 2025