Lies die bedienungsanleitung für Little Giant WGFP-75 (8 Seiten) kostenlos online; sie gehört zur Kategorie Wasserpumpe. Dieses Handbuch wurde von 23 Personen als hilfreich bewertet und erhielt im Schnitt 4.3 Sterne aus 12 Bewertungen. Hast du eine Frage zu Little Giant WGFP-75 oder möchtest du andere Nutzer dieses Produkts befragen? Stelle eine Frage
Seite 1/8

1
INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your Little Giant pump. Retain these
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. Little Giant pumps are carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your pump carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION,
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!
DESCRIPTION
This pump has been designed to operate in applications such
as waterfalls, streams, and fountainheads. It can also be used to
circulate the water in your pond. Unique features of this pump
line include a non-clogging vortex impeller, auto-resetting thermal
overload protection, stainless steel motor housing, and the ability
to pass solids with diameters up to 1.18”/30mm (WGFP-50) or
1.38”/35mm (WGFP-75 and WGFP-100).
CAUTION:To prevent damaging the pump, do not pump
abrasives such as sand or mud.
SAFETY GUIDELINES
Read all instructions and Safety Guidelines thoroughly. Failure
to follow the guidelines and instructions could result in serious
bodily injury and/or property damage.
RISK OF ELECTRICAL SHOCK:This pump is supplied with a
grounding conductor and grounding-type attachment plug. To
reduce the risk of electric shock, be certain that it is connected
only to a properly grounded, grounding-type receptacle. A
separate branch circuit is recommended. Do not remove the third
prong from the plug.
RISK OF ELECTRICAL SHOCK:This pump has not been certified
for use in swimming pool areas where people are present in the
water. Therefore, pump must not be used for this purpose.
WARNING:Do not use to pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc. Pump should only be
used with liquids compatible with pump component materials.
Failure to follow this warning can result in property damage,
personal injury, or death.
The pump motor is equipped with an automatic resetting thermal
protector and may restart unexpectedly.
Do not handle a pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water. Do not stand
in water while changing fuses or insert your finger into the fuse
socket.
Make certain the unit is disconnected from the power source, all
liquids are drained, and all pressure released within the system
before attempting to service the pump.
This appliance has no user-serviceable parts. The motor housing
of the pump is completely sealed and requires no service.
Disassembly of the motor housing or alteration of the power cord
will void all warranties. The power cord on these units cannot be
replaced.
Conformity with local and state electric codes is mandatory.
The National Electric Code requires that a ground fault circuit
interrupter (GFCI) be used in the branch circuit supplying sump,
utility, effluent and all fountain pumps, pool pumps and other pond
equipment.
All wiring and electrical work should be done by a qualified
electrician.
Secure the discharge line before starting the pump. An unsecured
discharge line will whip, possibly causing personal injury and/or
property damage.
Do not run the pump dry. It is designed to be cooled by the fluid it
moves. If the pump is run dry it will become dangerously hot, and
could cause personal injury and/or damage to the pump.
The pump’s motor housing contains a dielectric oil to aid in
bearing lubrication and motor heat dissipation. This oil is non-toxic
to aquatic life. However, suffocation can occur if oil is left on the
water surface. If oil escapes the motor housing it can be removed
from the surface quickly by placing newspapers on the water
surface to soak up the oil.
Do not lift or carry the pump by the power cord. Use the handle
on top of the pump.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not
connect the pump to any voltage other than that shown.
2. Plug the power cord directly into an electrical outlet.
MODELS • MODÈLES •
MODELOS
WGFP-50 • WGFP-75 •
WGFP-100
115V/60HZ
Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
MODEL
NO.
CATALOG
NO.
SAFETY
LISTING
DISCH.
SIZE
HPPHVOLTSHZAMPSWATTS
MOTOR
TYPE
GPH @ HEAD
SHUT
OFF
POWER
CORD
WEIGHT
(lbs.)
5’10’15’20’25’
WGFP-50566068cCSAus
2”
FNPT
1/21115607590PSC428035202780183080030’19’24.8
WGFP-75566069cCSAus
2”
FNPT
3/41115608847PSC4890434537503070226036’19’26.4
WGFP-100566070cCSAus
2”
FNPT
1111560121210PSC6400550047003700250035’19’38.2
Table 1 • Tableau 1 • Tabla 1
Produktspezifikationen
| Marke: | Little Giant |
| Kategorie: | Wasserpumpe |
| Modell: | WGFP-75 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Little Giant WGFP-75 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Wasserpumpe Little Giant
21 August 2025
21 August 2025
21 August 2025
17 August 2025
17 August 2025
19 Juli 2025
19 Juli 2025
19 Juli 2025
19 Juli 2025
11 Juni 2025
Bedienungsanleitung Wasserpumpe
Neueste Bedienungsanleitung für -Kategorien-
21 Januar 2026
19 Januar 2026
18 Januar 2026
14 Januar 2026
17 Dezember 2025
16 Dezember 2025
16 Dezember 2025
7 Dezember 2025
6 Dezember 2025
5 Dezember 2025